Cone beam computed tomography evaluation of regenerated buccal bone 5 years after simultaneous implant placement and guided bone regeneration procedures - a randomized, controlled clinical trial

被引:64
作者
Jung, Ronald E. [1 ]
Benic, Goran I. [1 ]
Scherrer, Daniela
Haemmerle, Christoph H. F. [1 ]
机构
[1] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland
关键词
bone substitute; cone beam CT; dental implant; GBR; graft material; long term; membranes; RCT; DENTAL IMPLANTS; BIODEGRADABLE MEMBRANE; BARRIER MEMBRANES; TITANIUM IMPLANTS; TOOTH EXTRACTION; IN-VITRO; DEFECTS; AUGMENTATION; SITES; ACCURACY;
D O I
10.1111/clr.12296
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this controlled clinical study was to compare a polyethylene glycol membrane (PEG) used for bone regeneration of peri-implant defects to a collagen membrane with respect to implant survival rate, dimensions of buccal peri-implant bone and mucosa. Materials and methods: Thirty-seven patients who received single tooth implants with simultaneous guided bone regeneration (GBR) in the posterior maxilla or mandible were enrolled in the study. Intra-operative heights of bone defects were assessed prior to bone augmentation. The defects were augmented with xenogenic bone mineral and randomly covered either with a porcine collagen membrane (control) or with a PEG membrane (test). Five years after implant placement, clinical evaluation and cone beam computed tomography (CBCT) scans were performed. Remaining height of bone defect, horizontal bone thickness, level of mucosal margin, and mucosal thickness were assessed in CBCT images. The difference of height of bone defect at implant placement and at 5-year follow-up was calculated. The differences between the two groups were analyzed using two-sided t-test and Mann-Whitney U-test. Results: After 5 years, 32 patients could be included and exhibited an implant survival rate of 100% for both groups. The buccal vertical bone gain between implant placement and 5-year follow-up amounted at 4.3 +/- 1.5 (SD) mm and 4.8 +/- 2.6 (SD) mm for the control and the test group, respectively (P = 0.493). Neither the bone height nor the thickness reached statistical significant differences between the two groups. The distance between mucosal margin and implant shoulder resulted in 0.8 +/- 0.7 (SD) mm in the control and 0.5 +/- 0.8 (SD) mm in the test group (P = 0.198). The mucosal thickness reached 1.4 +/- 0.5 (SD) mm in the control and 1.3 +/- 0.3 (SD) mm in the test group (P = 0.715). There were no significant correlations between height of bone defect at baseline and at follow-up examination and between different 5-year parameters. Conclusion: A polyethylene glycol membrane used for bone regeneration of peri-implant defects performed as successfully as a collagen membrane with respect to implant survival rate and dimensions of the buccal peri-implant bone and mucosa after 5 years.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 34 条
[1]  
Aghaloo TL, 2007, INT J ORAL MAX IMPL, V22, P49
[2]   In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography [J].
Benic, Goran I. ;
Sancho-Puchades, Manuel ;
Jung, Ronald E. ;
Deyhle, Hans ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) :378-383
[3]   Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: a clinical and cone beam computed tomography study [J].
Benic, Goran I. ;
Mokti, Muizzaddin ;
Chen, Chun-Jung ;
Weber, Hans-Peter ;
Haemmerle, Christoph H. F. ;
Gallucci, German O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (05) :560-566
[4]   Clinical and radiographic comparison of implants in regenerated or native bone: 5-year results [J].
Benic, Goran I. ;
Jung, Ronald E. ;
Siegenthaler, David W. ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :507-513
[5]   Hard-tissue alterations following immediate implant placement in extraction sites [J].
Botticelli, D ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2004, 31 (10) :820-828
[6]   Long-Term Stability of Contour Augmentation With Early Implant Placement Following Single Tooth Extraction in the Esthetic Zone: A Prospective, Cross-Sectional Study in 41 Patients With a 5- to 9-Year Follow-Up [J].
Buser, Daniel ;
Chappuis, Vivianne ;
Bornstein, Michael M. ;
Wittneben, Julia-Gabriela ;
Frei, Marc ;
Belser, Urs C. .
JOURNAL OF PERIODONTOLOGY, 2013, 84 (11) :1517-1527
[7]   Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT [J].
Draenert, F. G. ;
Coppenrath, E. ;
Herzog, P. ;
Muller, S. ;
Mueller-Lisse, U. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (04) :198-203
[8]  
Fugazzotto PA, 1997, INT J PERIODONT REST, V17, P293
[9]   A systematic review of the survival of implants in bone sites augmented with barrier membranes (guided bone regeneration) in partially edentulous patients [J].
Hämmerle, CHF ;
Jung, RE ;
Feloutzis, A .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 :226-231
[10]  
Jensen SS, 2009, INT J ORAL MAX IMPL, V24, P218