摘要
A nanoscale interface between two immiscible electrolyte solutions (ITIES) provides a unique analytical platform for the detection of ionic species of biological interest such as neurotransmitters and neuromodulators, especially those that are otherwise difficult to detect directly on a carbon electrode without electrode modification. We report the detection of acetylcholine, serotonin, and tryptamine on nanopipet electrode probes with sizes ranging from a radius of approximate to 7 to 35 nm. The transfer of these analytes across a 1,2-dichloroethane/water interface was studied by cyclic voltammetry and amperometry. Well-defined sigmoidal voltammograms were observed on the nanopipet electrodes within the potential window of artificial seawater for acetylcholine and tryptamine. The half wave transfer potential, E-1/2, of acetylcholine, tryptamine, and serotonin were found to be -0.11, -0.25, and -0.47 V vs E-1/2,E-TEA (term is defined later in experimental), respectively. The detection was linear in the range of 0.25-6 mM for acetylcholine and of 0.5-10 mM for tryptamine in artificial seawater. Transfer of serotonin was linear in the range of 0.15-8 mM in LiCl solution. The limit of detection for serotonin in LiCl on a radius approximate to 21 nm nanopipet electrode was 77 mu M, for acetylcholine on a radius approximate to 7 nm nanopipet electrode was 205 mu M, and for tryptamine on a radius approximate to 19 nm nanopipet electrode was 86 mu M. Nanopipet-supported ITIES probes have great potential to be used in nanometer spatial resolution measurements for the detection of neurotransmitters.
引用
收藏
页码:5095 / 5100
页数:6
相关论文
共 59 条
[1]   PROBING BRAIN CHEMISTRY WITH ELECTROANALYTICAL TECHNIQUES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :1126-&
[2]   Spatio-temporal concentration of acetylcholine in vertebrate synaptic cleft [J].
Aidoo, Anthony Y. ;
Ward, Kim .
MATHEMATICAL AND COMPUTER MODELLING, 2006, 44 (9-10) :952-962
[3]   Vesicular exocytosis under hypotonic conditions shows two distinct populations of dense core vesicles in bovine chromaffin cells [J].
Amatore, Christian ;
Arbault, Stephane ;
Bonifas, Imelda ;
Lemaitre, Frederic ;
Verchier, Yann .
CHEMPHYSCHEM, 2007, 8 (04) :578-585
[4]   Regulation of exocytosis in chromaffin cells by trans-insertion of lysophosphatidylcholine and arachidonic acid into the outer leaflet of the cell membrane [J].
Amatore, Christian ;
Arbault, Stephane ;
Bouret, Yann ;
Guille, Manon ;
Lemaitre, Frederic ;
Verchier, Yann .
CHEMBIOCHEM, 2006, 7 (12) :1998-2003
[5]   Scanning electrochemical microscopy. 40. Voltammetric ion-selective micropipet electrodes for probing ion transfer at bilayer lipid membranes [J].
Amemiya, S ;
Bard, AJ .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4940-4948
[6]  
Amemiya S., 2012, SCANNING ELECTROCHEM, P127
[7]   Electrochemical sensing and imaging based on ion transfer at liquid/liquid interfaces [J].
Amemiya, Shigeru ;
Kim, Jiyeon ;
Izadyar, Anahita ;
Kabagambe, Benjamin ;
Shen, Mei ;
Ishimatsu, Ryoichi .
ELECTROCHIMICA ACTA, 2013, 110 :836-845
[8]   Demonstration of two distributions of vesicle radius in the dopamine neuron of Planorbis corneus from electrochemical data [J].
Anderson, BB ;
Chen, GY ;
Gutman, DA ;
Ewing, AG .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 88 (02) :153-161
[9]   Selective voltammetric detection of dopamine in the presence of ascorbate [J].
Arrigan, DWM ;
Ghita, M ;
Beni, V .
CHEMICAL COMMUNICATIONS, 2004, (06) :732-733
[10]  
Bard A., 2001, Scanning Electrochemical Microscopy