Comparison of perfusion signal acquired by arterial spin labeling-prepared intravoxel incoherent motion (IVIM) MRI and conventional IVIM MRI to unravel the origin of the IVIM signal

被引:23
作者
Zhang, Xingxing [1 ]
Ingo, Carson [2 ]
Teeuwisse, Wouter M. [1 ]
Chen, Zhensen [3 ]
van Osch, Matthias J. P. [1 ,4 ]
机构
[1] Leiden Univ, Dept Radiol, CJ Gorter Ctr High Field MRI, Med Ctr, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, Chicago, IL 60611 USA
[3] Tsinghua Univ, Dept Biomed Engn, Ctr Biomed Imaging Res, Beijing, Peoples R China
[4] Leiden Univ, Leiden Inst Brain & Cognit, Leiden, Netherlands
关键词
intravoxel incoherent motion imaging; time-encoded pseudo-continuous ASL; (pseudo-) diffusion coefficient; IVIM; te-pCASL; ASL-IVIM; BRAIN PERFUSION; DIFFUSION; CONTRAST; INVERSION; WATER; CT;
D O I
10.1002/mrm.26723
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeApplications of intravoxel incoherent motion (IVIM) imaging in the brain are scarce, whereas it has been successfully applied in other organs with promising results. To better understand the cerebral IVIM signal, the diffusion properties of the arterial blood flow within different parts of the cerebral vascular tree (i.e., different generations of the branching pattern) were isolated and measured by employing an arterial spin labeling (ASL) preparation module before an IVIM readout. MethodsASL preparation was achieved by T-1-adjusted time-encoded pseudo-continuous ASL (te-pCASL). The IVIM readout module was achieved by introducing bipolar gradients immediately after the excitation pulse. The results of ASL-IVIM were compared with those of conventional IVIM to improve our understanding of the signal generation process of IVIM. ResultsThe pseudo-diffusion coefficient D* as calculated from ASL-IVIM data was found to decrease exponentially for postlabeling delays (PLDs) between 883 ms and 2176 ms, becoming relatively stable for PLDs longer than 2176 ms. The fast compartment of the conventional IVIM-experiment shows comparable apparent diffusion values to the ASL signal with PLDs between 1747 ms and 2176 ms. At the longest PLDs, the observed D* values (4.02.8x10(-3) mm(2)/s) are approximately 4.5 times higher than the slow compartment (0.90 +/- 0.05x10(-3) mm(2)/s) of the conventional IVIM experiment. ConclusionThis study showed much more complicated diffusion properties of vascular signal than the conventionally assumed single D* of the perfusion compartment in the two-compartment model of IVIM (biexponential behavior). Magn Reson Med 79:723-729, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 34 条
[1]   Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia [J].
Alsop, David C. ;
Detre, John A. ;
Golay, Xavier ;
Guenther, Matthias ;
Hendrikse, Jeroen ;
Hernandez-Garcia, Luis ;
Lu, Hanzhang ;
MacIntosh, Bradley J. ;
Parkes, Laura M. ;
Smits, Marion ;
van Osch, Matthias J. P. ;
Wang, Danny J. J. ;
Wong, Eric C. ;
Zaharchuk, Greg .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) :102-116
[2]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[3]   Comparison of 10 Perfusion MRI Parameters in 97 Sub-6-Hour Stroke Patients Using Voxel-Based Receiver Operating Characteristics Analysis [J].
Christensen, Soren ;
Mouridsen, Kim ;
Wu, Ona ;
Hjort, Niels ;
Karstoft, Henrik ;
Thomalla, Goetz ;
Roether, Joachim ;
Fiehler, Jens ;
Kucinski, Thomas ;
Ostergaard, Leif .
STROKE, 2009, 40 (06) :2055-2061
[4]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[5]  
Duong TQ, 2000, MAGNET RESON MED, V43, P393, DOI 10.1002/(SICI)1522-2594(200003)43:3<393::AID-MRM11>3.0.CO
[6]  
2-K
[7]   Intravoxel incoherent motion perfusion imaging in acute stroke: initial clinical experience [J].
Federau, C. ;
Sumer, S. ;
Becce, F. ;
Maeder, P. ;
O'Brien, K. ;
Meuli, R. ;
Wintermark, M. .
NEURORADIOLOGY, 2014, 56 (08) :629-635
[8]   Perfusion Measurement in Brain Gliomas with Intravoxel Incoherent Motion MRI [J].
Federau, C. ;
Meuli, R. ;
O'Brien, K. ;
Maeder, P. ;
Hagmann, P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (02) :256-262
[9]   Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience [J].
Federau, Christian ;
O'Brien, Kieran ;
Meuli, Reto ;
Hagmann, Patric ;
Maeder, Philippe .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) :624-632
[10]   Quantitative Measurement of Brain Perfusion with Intravoxel Incoherent Motion MR Imaging [J].
Federau, Christian ;
Maeder, Philippe ;
O'Brien, Kieran ;
Browaeys, Patrick ;
Meuli, Reto ;
Hagmann, Patric .
RADIOLOGY, 2012, 265 (03) :874-881