Noninvasive Neurally Adjusted Ventilator Assist Ventilation in the Postoperative Period Produces Better Patient-Ventilator Synchrony but Not Comfort

被引:6
作者
Harnisch, L. O. [1 ]
Olgemoeller, U. [2 ]
Mann, J. [1 ]
Quintel, M. [1 ]
Moerer, O. [1 ]
机构
[1] Univ Med Ctr Gottingen, Dept Anaesthesiol, Robert Koch Str 40, D-37099 Gottingen, Germany
[2] Univ Med Ctr Gottingen, Dept Cardiol & Pulmonol, Robert Koch Str 40, D-37099 Gottingen, Germany
关键词
PRESSURE SUPPORT VENTILATION; MECHANICAL VENTILATION; RESPIRATORY-FAILURE; ASYNCHRONY; NAVA; INDEX; TIME; QUALITY;
D O I
10.1155/2020/4705042
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background. Noninvasive neurally adjusted ventilatory assist (NAVA) has been shown to improve patient-ventilator interaction in many settings. There is still scarce data with regard to postoperative patients indicated for noninvasive ventilation (NIV) which this study elates. The purpose of this trial was to evaluate postoperative patients for synchrony and comfort in noninvasive pressure support ventilation (NIV-PSV) vs. NIV-NAVA. Methods. Twenty-two subjects received either NIV-NAVA or NIV-PSV in an object-blind, prospective, randomized, crossover fashion (observational trial). We evaluated blood gases and ventilator tracings throughout as well as comfort of ventilation at the end of each ventilation phase. Results. There was an effective reduction in ventilator delays (p < 0.001) and negative pressure duration in NIV-NAVA as compared to NIV-PSV (p < 0.001). Although we used optimized settings in NIV-PSV, explaining the overall low incidence of asynchrony, NIV-NAVA led to reductions in the NeuroSync-index (p < 0.001) and all types of asynchrony except for double triggering that was significantly more frequent in NIV-NAVA vs. NIV-PSV (p = 0.02); ineffective efforts were reduced to zero by use of NIV-NAVA. In our population of previously lung-healthy subjects, we did not find differences in blood gases and patient comfort between the two modes. Conclusion. In the postoperative setting, NIV-NAVA is well suitable for use and effective in reducing asynchronies as well as a surrogate for work of breathing. Although increased synchrony was not transferred into an increased comfort, there was an advantage with regard to patient-ventilator interaction. The trial was registered at the German clinical Trials Register (DRKS no.: DRKS00005408).
引用
收藏
页数:8
相关论文
共 36 条
[1]   Evaluation of the catheter positioning for neurally adjusted ventilatory assist [J].
Barwing, Jurgen ;
Ambold, Markus ;
Linden, Nadine ;
Quintel, Michael ;
Moerer, Onnen .
INTENSIVE CARE MEDICINE, 2009, 35 (10) :1809-1814
[2]   Prolonged neural expiratory time induced by mechanical ventilation in infants [J].
Beck, J ;
Tucci, M ;
Emeriaud, G ;
Lacroix, J ;
Sinderby, C .
PEDIATRIC RESEARCH, 2004, 55 (05) :747-754
[3]   Improved synchrony and respiratory unloading by neurally adjusted ventilatory assist (NAVA) in lung-injured rabbits [J].
Beck, Jennifer ;
Campoccia, Francesca ;
Allo, Jean-Christophe ;
Brander, Lukas ;
Brunet, Fabrice ;
Slutsky, Arthur S. ;
Sinderby, Christer .
PEDIATRIC RESEARCH, 2007, 61 (03) :289-294
[4]   Neurally Adjusted Ventilatory Assist vs Pressure Support Ventilation for Noninvasive Ventilation During Acute Respiratory Failure A Crossover Physiologic Study [J].
Bertrand, Pierre-Marie ;
Futier, Emmanuel ;
Coisel, Yannael ;
Matecki, Stefan ;
Jaber, Samir ;
Constantin, Jean-Michel .
CHEST, 2013, 143 (01) :30-36
[5]   Asynchronies during mechanical ventilation are associated with mortality [J].
Blanch, Lluis ;
Villagra, Ana ;
Sales, Bernat ;
Montanya, Jaume ;
Lucangelo, Umberto ;
Lujan, Manel ;
Garcia-Esquirol, Oscar ;
Chacon, Encarna ;
Estruga, Anna ;
Oliva, Joan C. ;
Hernandez-Abadia, Alberto ;
Albaiceta, Guillermo M. ;
Fernandez-Mondejar, Enrique ;
Fernandez, Rafael ;
Lopez-Aguilar, Josefina ;
Villar, Jesus ;
Murias, Gaston ;
Kacmarek, Robert M. .
INTENSIVE CARE MEDICINE, 2015, 41 (04) :633-641
[6]   Neural control of ventilation prevents both over-distension and de-recruitment of experimentally injured lungs [J].
Brander, Lukas ;
Moerer, Onnen ;
Hedenstierna, Goran ;
Beck, Jennifer ;
Takala, Jukka ;
Slutsky, Arthur S. ;
Sinderby, Christer .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2017, 237 :57-67
[7]   New Setting of Neurally Adjusted Ventilatory Assist during Noninvasive Ventilation through a Helmet [J].
Cammarota, Gianmaria ;
Longhini, Federico ;
Perucca, Raffaella ;
Ronco, Chiara ;
Colombo, Davide ;
Messina, Antonio ;
Vaschetto, Rosanna ;
Navalesi, Paolo .
ANESTHESIOLOGY, 2016, 125 (06) :1181-1189
[8]   Patient-ventilator asynchronies: may the respiratory mechanics play a role? [J].
Carlucci, Annalisa ;
Pisani, Lara ;
Ceriana, Piero ;
Malovini, Alberto ;
Nava, Stefano .
CRITICAL CARE, 2013, 17 (02)
[9]   Comparison Between Neurally Adjusted Ventilatory Assist and Pressure Support Ventilation Levels in Terms of Respiratory Effort [J].
Carteaux, Guillaume ;
Cordoba-Izquierdo, Ana ;
Lyazidi, Aissam ;
Heunks, Leo ;
Thille, Arnaud W. ;
Brochard, Laurent .
CRITICAL CARE MEDICINE, 2016, 44 (03) :503-511
[10]   Patient-ventilator trigger asynchrony in prolonged mechanical ventilation [J].
Chao, DC ;
Scheinhorn, DJ ;
StearnHassenpflug, M .
CHEST, 1997, 112 (06) :1592-1599