Research on improvements of using electronic current transformer on distance protection

被引:3
|
作者
Chen, Qingqian [1 ]
Hou, Hui [1 ]
You, Dahai [1 ]
Yin, Xianggen [1 ]
Yao, Zhandong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Coll Elect & Elect Engn, Wuhan 430074, Hubei, Peoples R China
来源
2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3 | 2007年
关键词
current transformers; distance protection; Electronic Current Transformer; optical fiber transducers; saturation;
D O I
10.1109/UPEC.2007.4468958
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Traditional magnetic current transformer (CT) always has the problem of saturation, which depresses the accuracy of distance protection's impedance measurement and shortens its protection zone. Based on this analysis, traditional measures to solve this problem are summarized first, and then the newly developed electronic current transformer (ECT) is introduced as a new way to solve the problem. Because of its high accuracy, high stability, wide frequency band, and most of all, without the problem of magnetic saturation, ECT has become a popular substitute for traditional CT. It can improve the starting unit, phase selecting unit, impedance unit and other functional units of distance protection. Experimental analysis shows that using ECT instead of traditional CT can enhance the operating accuracy and reliability of distance protection greatly.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [1] Applying electronic current transformer to transformer differential protection
    College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 4 (47-53):
  • [2] The Impact Of Current Transformer Saturation On The Distance Protection
    Wannous, Kinan
    Toman, Petr
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 257 - 261
  • [3] Improvements in Transformer Protection and Control
    Guzman, Armando
    Fischer, Normann
    Labuschagne, Casper
    2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, : 563 - 579
  • [4] Transmission Line Distance Protection Under Current Transformer Saturation
    Zheng, Yuping
    Wu, Tonghua
    Hong, Feng
    Yao, Gang
    Chai, Jimin
    Wei, Zhinong
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (01) : 68 - 76
  • [5] Transmission Line Distance Protection Under Current Transformer Saturation
    Yuping Zheng
    Tonghua Wu
    Feng Hong
    Gang Yao
    Jimin Chai
    Zhinong Wei
    JournalofModernPowerSystemsandCleanEnergy, 2021, 9 (01) : 68 - 76
  • [6] The research of the adaptive transformer current differential protection criterion
    Yu, Jia-Xia
    Zhang, Heng-Tai
    Ge, Yao-Zhong
    He, Zhan-Hu
    Yun, Bao-Ji
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (18): : 115 - 119
  • [7] Research and design of integral circuit for electronic current transformer
    Zhang, Xingchao
    Wang, Lu
    Yang, Chengzhi
    4TH INTERNATIONAL CONFERENCE ON APPLIED MATERIALS AND MANUFACTURING TECHNOLOGY, 2018, 423
  • [8] Discrete Frechet distance algorithm based criterion of transformer differential protection with the immunity to saturation of current transformer
    Weng, Hanli
    Wang, Sheng
    Wan, Yi
    Lin, Xiangning
    Li, Zhenxing
    Huang, Jingguang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 115
  • [9] Experimental research on measuring and testing techniques of electronic current transformer
    Yu, WB
    Zhang, GQ
    Li, YS
    Gao, H
    Guo, ZZ
    Yang, YH
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2004, : 621 - 626
  • [10] Research of on-line calibration for DC electronic current transformer
    Qian, Zheng
    Wang, Zheng
    Liu, Shaoyu
    Li, Yuling
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 1088 - +