Effect of EEG Referencing Methods on Auditory Mismatch Negativity

被引:15
作者
Mahajan, Yatin [1 ,2 ]
Peter, Varghese [1 ]
Sharma, Mridula [2 ,3 ]
机构
[1] Western Sydney Univ, MARCS Inst Brain Behav & Dev, Penrith, NSW, Australia
[2] HEARing CRC, Melbourne, Vic, Australia
[3] Macquarie Univ, Dept Linguist, Australian Hearing Hub, Sydney, NSW, Australia
来源
FRONTIERS IN NEUROSCIENCE | 2017年 / 11卷
关键词
mismatch negativity; event related potential; reference; REST; EVENT-RELATED POTENTIALS; EVOKED-POTENTIALS; INFINITY REFERENCE; AVERAGE REFERENCE; BRAIN POTENTIALS; SYSTEM ACTIVITY; SPEECH STIMULI; T-COMPLEX; CHILDREN; MATURATION;
D O I
10.3389/fnins.2017.00560
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Auditory event-related potentials (ERPs) have consistently been used in the investigation of auditory and cognitive processing in the research and clinical laboratories. There is currently no consensus on the choice of appropriate reference for auditory ERPs. The most commonly used references in auditory ERR research are the mathematically linked-mastoids (LM) and average referencing (AVG). Since LM and AVG referencing procedures do not solve the issue of electrically-neutral reference, Reference Electrode Standardization Technique (REST) was developed to create a neutral reference for EEG recordings. The aim of the current research is to compare the influence of the reference on amplitude and latency of auditory mismatch negativity (MMN) as a function of magnitude of frequency deviance across three commonly used electrode montages (16, 32, and 64-channel) using REST, LM, and AVG reference procedures. The current study was designed to determine if the three reference methods capture the variation in amplitude and latency of MMN with the deviance magnitude. We recorded MMN from 12 normal hearing young adults in an auditory oddball paradigm with 1,000 Hz pure tone as standard and 1,030, 1,100, and 1,200 Hz as small, medium and large frequency deviants, respectively. The EEG data recorded to these sounds was re-referenced using REST, LM, and AVG methods across 16-, 32-, and 64-channel EEG electrode montages. Results revealed that while the latency of MMN decreased with increment in frequency of deviant sounds, no effect of frequency deviance was present for amplitude of MMN. There was no effect of referencing procedure on the experimental effect tested. The amplitude of MMN was largest when the ERR was computed using LM referencing and the REST referencing produced the largest amplitude of MMN for 64-channel montage. There was no effect of electrode-montage on AVG referencing induced ERPs. Contrary to our predictions, the results suggest that the auditory MMN elicited as a function of increments in frequency deviance does not depend on the choice of referencing procedure. The results also suggest that auditory ERPs generated using REST referencing is contingent on the electrode arrays more than the AVG referencing.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Developmental Changes of Visual Mismatch Negativity
    Tomio, N.
    Fuchigami, T.
    Fujita, Y.
    Okubo, O.
    Mugishima, H.
    NEUROPHYSIOLOGY, 2012, 44 (02) : 138 - 143
  • [22] Temporal integration of auditory stimulus deviance as reflected by the mismatch negativity
    Sussman, E
    Winkler, I
    Ritter, W
    Alho, K
    Näätänen, R
    NEUROSCIENCE LETTERS, 1999, 264 (1-3) : 161 - 164
  • [23] Auditory Mismatch Negativity (MMN) is Unaffected by Acute Exacerbation in Schizophrenia
    Fisher, Derek
    Smith, Dylan
    Labelle, Alain
    Knott, Verner
    BIOLOGICAL PSYCHIATRY, 2021, 89 (09) : S123 - S123
  • [24] MISMATCH NEGATIVITY AREA AND AGE-RELATED AUDITORY MEMORY
    PEKKONEN, E
    JOUSMAKI, V
    PARTANEN, J
    KARHU, J
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 87 (05): : 321 - 325
  • [25] Beyond the real world: attention debates in auditory mismatch negativity
    Chung, Kyungmi
    Park, Jin Young
    NEUROREPORT, 2018, 29 (06) : 472 - 477
  • [26] Auditory mismatch negativity is larger during exhalation than inhalation
    Mizuhara, Keita
    Li, Lingjun
    Nittono, Hiroshi
    MEDICINE, 2024, 103 (48) : e40683
  • [27] Spectral interactions, but no mismatch negativity, in auditory cortex of anesthetized rat
    Lazar, R
    Metherate, R
    HEARING RESEARCH, 2003, 181 (1-2) : 51 - 56
  • [28] Auditory sensory memory and the aging brain: A mismatch negativity study
    Cooper, RJ
    Todd, J
    McGill, K
    Michie, PT
    NEUROBIOLOGY OF AGING, 2006, 27 (05) : 752 - 762
  • [29] Auditory processing in autism spectrum disorder: Mismatch negativity deficits
    Vlaskamp, Chantal
    Oranje, Bob
    Madsen, Gitte Falcher
    Jepsen, Jens Richardt Mollegaard
    Durston, Sarah
    Cantio, Cathriona
    Glenthoj, Birte
    Bilenberg, Niels
    AUTISM RESEARCH, 2017, 10 (11) : 1857 - 1865
  • [30] Auditory Mismatch Negativity in Schizophrenia: A Neurodevelopmental Perspective
    Corcoran, Cheryl
    Martinez, Antigona
    Dias, Elisa
    Stoops, Anastasia
    Sehatpour, Pejman
    Javitt, Daniel
    NEUROPSYCHOPHARMACOLOGY, 2015, 40 : S404 - S404