Improved high-resolution ultrasonic imaging of the eye

被引:18
作者
Silverman, Ronald H. [1 ,2 ]
Ketterling, Jeffrey A. [2 ]
Mamou, Jonathan [2 ]
Coleman, D. Jackson [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Dept Ophthalmol, New York, NY 10021 USA
[2] Riverside Res Inst, New York, NY USA
关键词
D O I
10.1001/archopht.126.1.94
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Currently, virtually all clinical diagnostic ultrasound systems used in ophthalmology are based on fixed-focus, single-element transducers. High-frequency (>= 20-MHz) transducers introduced to ophthalmology during the last decade have led to improved resolution and diagnostic capabilities for assessment of the anterior segment and the retina. However, single-element transducers are restricted to a small depth of field, limiting their capacity to image the eye as a whole. We fabricated a 20-MHz annular array probe prototype consisting of 5 concentric transducer elements and scanned an ex vivo human eye. Synthetically focused images of the bank eye showed improved depth of field and sensitivity, allowing simultaneous display of the anterior and posterior segments and the full lens contour. This capability may be useful in assessment of vitreoretinal pathologies and investigation of the accommodative mechanism.
引用
收藏
页码:94 / 97
页数:4
相关论文
共 10 条
[1]   THE APPLICATION OF ULTRASONIC LOCATING TECHNIQUES TO OPHTHALMOLOGY .2. ULTRASONIC SLIT LAMP IN THE ULTRASONIC VISUALIZATION OF SOFT TISSUES [J].
BAUM, G ;
GREENWOOD, I .
ARCHIVES OF OPHTHALMOLOGY, 1958, 60 (02) :263-279
[2]   Design and fabrication of annular arrays for high-frequency ultrasound [J].
Brown, JA ;
Démoré, CEM ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (08) :1010-1017
[3]   Development of a 35-MHz piezo-composite ultrasound array for medical imaging [J].
Cannata, JM ;
Williams, JA ;
Zhou, QF ;
Ritter, TA ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) :224-236
[4]   High-resolution ultrasonic imaging of the posterior segment [J].
Coleman, DJ ;
Silverman, RH ;
Chabi, A ;
Rondeau, MJ ;
Shung, KK ;
Cannata, J ;
Lincoff, H .
OPHTHALMOLOGY, 2004, 111 (07) :1344-1351
[5]   Operational verification of a 40-MHz annular army transducer [J].
Ketterling, JA ;
Ramachandran, S ;
Aristizábal, O .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (03) :623-630
[6]   Design and fabrication of a 40-MHz annular army transducer [J].
Ketterling, JA ;
Aristizábal, O ;
Turnbull, DH ;
Lizzi, FL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (04) :672-681
[7]  
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287
[8]   A 30-MHz piezo-composite ultrasound array for medical imaging applications [J].
Ritter, TA ;
Shrout, TR ;
Tutwiler, R ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) :217-230
[9]   High-frequency ultrasonic imaging of the anterior segment using an annular array transducer [J].
Silverman, Ronald H. ;
Ketterling, Jeffrey A. ;
Coleman, D. Jackson .
OPHTHALMOLOGY, 2007, 114 (04) :816-822
[10]   High-frequency ultrasound annular-array imaging. Part I: Array design and fabrication [J].
Snook, KA ;
Hu, CH ;
Shrout, TR ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) :300-308