Evaluation of different random estimation methods for the MADPET-II small animal PET scanner using GATE

被引:0
作者
Torres-Espallardo, Irene [1 ]
Rafecas, Magdalena [2 ]
Spanoudaki, Virginia Ch. [1 ]
McElroy, David P. [3 ]
Ziegler, Sibylle I. [1 ]
机构
[1] Tech Univ Muenchen, Klinikum Rechts Isar, Nukl Med Klin, Munich, Germany
[2] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
[3] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON, Canada
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
PET; small animal; GATE; random estimation; individual read-out; inter-crystal scatter;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The validity of random estimation techniques has been studied for various low energy thresholds (LETs) for singles list-mode simulated data sets of the MADPET-II small animal PET scanner. MADPET-II is a dual layer PET scanner prototype consisting of LSO crystals read individually from avalanche photo-diodes (APDs). The simulations have been performed using GATE simulation toolkit. Several sources have been simulated, such as point, planar, cylindrical and Derenzo. We have evaluated the randoms using three standard methods, the delayed window (DW), singles rate (SR) and time histogram fitting (THF). In addition, we know from simulations how to discriminate between random and true coincidences. Therefore, we compare the randoms estimated with the above methods with the number of randoms obtained using GATE information. An overestimation in the number of randoms has been observed for DW and SR methods. We pointed out that this mismatch is due to the inter-crystal scatter (events that take place between the crystals) since is reduced for LETs higher than 255 keV. Nevertheless, this discrepancy does not have a significant effect to the quality of the reconstructed images.
引用
收藏
页码:3148 / 3150
页数:3
相关论文
共 2 条
  • [1] Monte Carlo simulation in PET and SPECT instrumentation using GATE
    Assié, K
    Breton, V
    Buvat, I
    Comtat, C
    Jan, S
    Krieguer, M
    Lazaro, D
    Morel, C
    Rey, M
    Santin, G
    Simon, L
    Staelens, S
    Strul, D
    Vieira, JM
    Van de Walle, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) : 180 - 189
  • [2] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .4. EFFECT OF ACCIDENTAL COINCIDENCES
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    KUHL, DE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) : 391 - 400