Baseline wandering removal by using independent component analysis to single-channel ECG data

被引:0
|
作者
Barati, Zeinab [1 ]
Ayatollahi, Ahmad [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Biomed Engn, Tehran, Iran
来源
2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2 | 2006年
关键词
baseline wandering; Independent Component Analysis; single channel ECG; Ventricular Late Potentials;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Removing baseline wandering from ECG records is one of the first steps for processing signals. Generally baseline wandering produces artifactual data when measuring ECG parameters. In this paper, we show the ability of Independent Component Analysis (ICA) technique in removing baseline wandering from ECG by utilizing Single-Channel data. For applying ICA to single channel data, multi-channel signals are constructed by adding some delay to original data. For validation the effectiveness of proposed method, we applied ICA to constructed channels derived from each Frank lead in HRECG (High-Resolution Electrocardiogram) data as a preprocessing step in order to detect Ventricular Late Potentials (VLPs) by Simson's method. Results derived by our approach were compared with those obtained from traditional high-pass filtering for removing baseline wandering. We found perfect accordance between these two groups of results in detecting VLP positive patients from healthy control subjects.
引用
收藏
页码:152 / +
页数:2
相关论文
共 50 条
  • [1] Separation of Sources From Single-Channel EEG Signals Using Independent Component Analysis
    Maddirala, Ajay Kumar
    Shaik, Rafi Ahamed
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (02) : 382 - 393
  • [2] GNSS Vertical Coordinate Time Series Analysis Using Single-Channel Independent Component Analysis Method
    Wei Peng
    Wujiao Dai
    Rock Santerre
    Changsheng Cai
    Cuilin Kuang
    Pure and Applied Geophysics, 2017, 174 : 723 - 736
  • [3] GNSS Vertical Coordinate Time Series Analysis Using Single-Channel Independent Component Analysis Method
    Peng, Wei
    Dai, Wujiao
    Santerre, Rock
    Cai, Changsheng
    Kuang, Cuilin
    PURE AND APPLIED GEOPHYSICS, 2017, 174 (02) : 723 - 736
  • [4] Development of a new signal processing algorithm based on independent component analysis for single channel ECG data
    Lee, J
    Lee, KJ
    Yoo, SK
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 224 - 226
  • [5] ECG ADAPTER AS SINGLE-CHANNEL ECG INSTRUMENT
    不详
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1980, 122 (19): : 54 - 54
  • [6] Normalization of single-channel DNA array data by principal component analysis
    Stoyanova, R
    Querec, TD
    Brown, TR
    Patriotis, C
    BIOINFORMATICS, 2004, 20 (11) : 1772 - 1784
  • [7] A denoising method of microseismic data based on a single-channel phase space reconstruction and independent component analysis algorithm
    Meng, Huijie
    Zeng, Huahui
    Xu, Xingrong
    Wang, Yanxiang
    Liu, Huan
    Li, Dongsheng
    GEOPHYSICAL PROSPECTING, 2024, 72 (05) : 1564 - 1578
  • [8] Baseline Wandering Removal from ECG Signal by Wandering Path Finding Algorithm
    Rahman, Md. Asadur
    Milu, Md. Mahmudul Haque
    Anjum, Anika
    Khanam, Farzana
    Ahmad, Mohiuddin
    2017 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT 2017), 2017,
  • [9] ECG data compression by independent component analysis
    Guilhon, D
    Medeiros, E
    Barros, AK
    2005 IEEE WORKSHOP ON MACHINE LEARNING FOR SIGNAL PROCESSING (MLSP), 2005, : 189 - 193
  • [10] Removal of baseline wandering in ECG signal by improved detrending method
    Shin, Seung-Won
    Kim, Kyeong-Seop
    Song, Chul-Gyu
    Lee, Jeong-Whan
    Kim, Jeong-Hwan
    Jeung, Gyeo-Wun
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1087 - S1093