Photon-Counting Multienergy Computed Tomography With Spectrally Optimized Contrast Media for Plaque Removal and Stenosis Assessment

被引:26
作者
Sartoretti, Thomas [1 ]
Eberhard, Matthias [1 ]
Nowak, Tristan [2 ]
Gutjahr, Ralf [2 ,3 ]
Jost, Gregor [4 ]
Pietsch, Hubertus [4 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Alkadhi, Hatem [1 ]
Euler, Andre [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Tech Univ Munich, Comp Aided Med Procedures & Augmented Real, Dept Informat, Garching, Germany
[4] Bayer AG, Berlin, Germany
关键词
tomography; x-ray computed; phantoms; imaging; photons; contrast media; CORONARY CT ANGIOGRAPHY; AGENTS; TUNGSTEN; IMPACT;
D O I
10.1097/RLI.0000000000000773
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to systematically evaluate the potential to combine investigational contrast media with spectrally optimized energy-thresholding of photon-counting detector computed tomography (PCCT) for subtraction of calcified plaques in a coronary artery stenosis phantom. Methods A small vessel phantom containing 3 fillable tubes (diameter, 3 mm each) with calcified plaques was placed into an anthropomorphic chest phantom. The plaques had incremental thicknesses ranging from 0.3 to 2.7 mm, simulating vessel stenoses ranging from 10% to 90% of the lumen diameter. The phantom was filled with 5 different investigational contrast media (iodine, bismuth, hafnium, holmium, and tungsten) at equal mass concentrations (15 mg/mL) and was imaged on a prototype PCCT at 140 kVp using optimized, contrast media-dependent energy thresholds. Contrast maps (CMs) were reconstructed for each contrast medium by applying a linear 2-material decomposition algorithm. Image noise magnitude and noise texture of CM were compared among the contrast media using the noise power spectrum. Two blinded readers independently rated the vessel lumen visualization on short-axis and the overall subjective image quality on long-axis CM relative to iodine as the reference standard. Four readers determined the highest degree of stenosis that could be assessed with high diagnostic confidence on long-axis CM. Results Average image noise on CM was lower for tungsten (49 HU) and hafnium (62 HU) and higher for bismuth (81 HU) and holmium (165 HU) compared with iodine (78 HU). Noise texture of CM was similar among the contrast media. Interreader agreement for vessel lumen visualization on short-axis CM ranged from moderate to excellent (k = 0.567-0.814). Compared with iodine, lumen visualization of each reader was improved using tungsten (P < 0.001 for both readers), similar to improved using hafnium (P = 0.008, P = 0.29), similar using bismuth (P = 0.38, P = 0.69), and decreased using holmium (both, P < 0.001). Overall subjective image quality was similar for holmium and superior for tungsten, hafnium, and bismuth as compared with iodine. Higher-degree stenoses were evaluable with high confidence using tungsten (mean, 70%; interquartile range, 70%-70%), bismuth (70%; 60%-70%), and hafnium (75%; 70%-80%) compared with iodine (50%; 50%-60%) and holmium (50%; 50%-60%). Conclusions Spectral optimization in PCCT combined with investigational contrast media can improve calcium subtraction and stenosis assessment in small vessels. Contrast maps of tungsten and, to a lesser extent, hafnium as contrast media yielded superior image noise properties and improved vessel lumen visualization, along with a higher subjective image quality compared with the reference standard iodine.
引用
收藏
页码:563 / 570
页数:8
相关论文
共 37 条
  • [21] Rajagopal JR., 2020, ACAD RADIOL, VS1076, P30456
  • [22] Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
    Rajendran, Kishore
    Voss, Benjamin A.
    Zhou, Wei
    Tao, Shengzhen
    DeLone, David R.
    Lane, John, I
    Weaver, Jayse M.
    Carlson, Matthew L.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 91 - 100
  • [23] Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography A Feasibility Animal Study
    Ren, Liqiang
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (10) : 688 - 694
  • [24] K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    Roessl, E.
    Proksa, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15) : 4679 - 4696
  • [25] High Atomic Number Contrast Media Offer Potential for Radiation Dose Reduction in Contrast-Enhanced Computed Tomography
    Roessler, Ann-Christin
    Hupfer, Martin
    Kolditz, Daniel
    Jost, Gregor
    Pietsch, Hubertus
    Kalender, Willi A.
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (04) : 249 - 254
  • [26] Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233
    Samei, Ehsan
    Bakalyar, Donovan
    Boedeker, Kirsten L.
    Brady, Samuel
    Fan, Jiahua
    Leng, Shuai
    Myers, Kyle J.
    Popescu, Lucretiu M.
    Giraldo, Juan Carlos Ramirez
    Ranallo, Frank
    Solomon, Justin
    Vaishnav, Jay
    Wang, Jia
    [J]. MEDICAL PHYSICS, 2019, 46 (11) : E735 - E756
  • [27] Photon-counting CT with tungsten as contrast medium: Experimental evidence of vessel lumen and plaque visualization
    Sartoretti, Thomas
    Eberhard, Matthias
    Rueschoff, Jan Hendrik
    Pietsch, Hubertus
    Jost, Gregor
    Nowak, Tristan
    Schmidt, Bernhard
    Flohr, Thomas
    Euler, Andre
    Alkadhi, Hatem
    [J]. ATHEROSCLEROSIS, 2020, 310 : 11 - 16
  • [28] Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography
    Schoeckel, Laura
    Jost, Gregor
    Seidensticker, Peter
    Lengsfeld, Philipp
    Palkowitsch, Petra
    Pietsch, Hubertus
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (09) : 592 - 597
  • [29] Lesion Detectability and Radiation Dose in Spiral Breast CT With Photon-Counting Detector Technology A Phantom Study
    Shim, Sojin
    Saltybaeva, Natalia
    Berger, Nicole
    Marcon, Magda
    Alkadhi, Hatem
    Boss, Andreas
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (08) : 515 - 523
  • [30] Quantitative comparison of noise texture across CT scanners from different manufacturers
    Solomon, Justin B.
    Christianson, Olav
    Samei, Ehsan
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6048 - 6055