Photon-Counting Multienergy Computed Tomography With Spectrally Optimized Contrast Media for Plaque Removal and Stenosis Assessment

被引:26
作者
Sartoretti, Thomas [1 ]
Eberhard, Matthias [1 ]
Nowak, Tristan [2 ]
Gutjahr, Ralf [2 ,3 ]
Jost, Gregor [4 ]
Pietsch, Hubertus [4 ]
Schmidt, Bernhard [2 ]
Flohr, Thomas [2 ]
Alkadhi, Hatem [1 ]
Euler, Andre [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Siemens Healthcare GmbH, Forchheim, Germany
[3] Tech Univ Munich, Comp Aided Med Procedures & Augmented Real, Dept Informat, Garching, Germany
[4] Bayer AG, Berlin, Germany
关键词
tomography; x-ray computed; phantoms; imaging; photons; contrast media; CORONARY CT ANGIOGRAPHY; AGENTS; TUNGSTEN; IMPACT;
D O I
10.1097/RLI.0000000000000773
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to systematically evaluate the potential to combine investigational contrast media with spectrally optimized energy-thresholding of photon-counting detector computed tomography (PCCT) for subtraction of calcified plaques in a coronary artery stenosis phantom. Methods A small vessel phantom containing 3 fillable tubes (diameter, 3 mm each) with calcified plaques was placed into an anthropomorphic chest phantom. The plaques had incremental thicknesses ranging from 0.3 to 2.7 mm, simulating vessel stenoses ranging from 10% to 90% of the lumen diameter. The phantom was filled with 5 different investigational contrast media (iodine, bismuth, hafnium, holmium, and tungsten) at equal mass concentrations (15 mg/mL) and was imaged on a prototype PCCT at 140 kVp using optimized, contrast media-dependent energy thresholds. Contrast maps (CMs) were reconstructed for each contrast medium by applying a linear 2-material decomposition algorithm. Image noise magnitude and noise texture of CM were compared among the contrast media using the noise power spectrum. Two blinded readers independently rated the vessel lumen visualization on short-axis and the overall subjective image quality on long-axis CM relative to iodine as the reference standard. Four readers determined the highest degree of stenosis that could be assessed with high diagnostic confidence on long-axis CM. Results Average image noise on CM was lower for tungsten (49 HU) and hafnium (62 HU) and higher for bismuth (81 HU) and holmium (165 HU) compared with iodine (78 HU). Noise texture of CM was similar among the contrast media. Interreader agreement for vessel lumen visualization on short-axis CM ranged from moderate to excellent (k = 0.567-0.814). Compared with iodine, lumen visualization of each reader was improved using tungsten (P < 0.001 for both readers), similar to improved using hafnium (P = 0.008, P = 0.29), similar using bismuth (P = 0.38, P = 0.69), and decreased using holmium (both, P < 0.001). Overall subjective image quality was similar for holmium and superior for tungsten, hafnium, and bismuth as compared with iodine. Higher-degree stenoses were evaluable with high confidence using tungsten (mean, 70%; interquartile range, 70%-70%), bismuth (70%; 60%-70%), and hafnium (75%; 70%-80%) compared with iodine (50%; 50%-60%) and holmium (50%; 50%-60%). Conclusions Spectral optimization in PCCT combined with investigational contrast media can improve calcium subtraction and stenosis assessment in small vessels. Contrast maps of tungsten and, to a lesser extent, hafnium as contrast media yielded superior image noise properties and improved vessel lumen visualization, along with a higher subjective image quality compared with the reference standard iodine.
引用
收藏
页码:563 / 570
页数:8
相关论文
共 37 条
  • [1] The Future of Computed Tomography Personalized, Functional, and Precise
    Alkadhi, Hatem
    Euler, Andre
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (09) : 545 - 555
  • [2] Diagnostic Accuracy of Rapid Kilovolt Peak-Switching Dual-Energy CT Coronary Angiography in Patients With a High Calcium Score
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bertella, Erika
    Conte, Edoardo
    Segurini, Chiara
    Giovannardi, Marta
    Baggiano, Andrea
    Annoni, Andrea
    Formenti, Alberto
    Petulla, Maria
    Beltrama, Virginia
    Volpato, Valentina
    Bartorelli, Antonio L.
    Trabattoni, Daniela
    Fiorentini, Cesare
    Pepi, Mauro
    [J]. JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) : 746 - 748
  • [3] High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography
    Bartlett, David J.
    Koo, Chi Wan
    Bartholmai, Brian J.
    Rajendran, Kishore
    Weaver, Jayse M.
    Halaweish, Ahmed E.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    [J]. INVESTIGATIVE RADIOLOGY, 2019, 54 (03) : 129 - 137
  • [4] Hafnium-Based Contrast Agents for X-ray Computed Tomography
    Berger, Markus
    Bauser, Marcus
    Frenzel, Thomas
    Hilger, Christoph Stephan
    Jost, Gregor
    Lauria, Silvia
    Morgenstern, Bernd
    Neis, Christian
    Pietsch, Hubertus
    Suelzle, Detlev
    Hegetschweiler, Kaspar
    [J]. INORGANIC CHEMISTRY, 2017, 56 (10) : 5757 - 5761
  • [5] Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis
    Bratke, Grischa
    Hickethier, Tilman
    Bar-Ness, Daniel
    Bunck, Alexander Christian
    Maintz, David
    Pahn, Gregor
    Coulon, Philippe
    Si-Mohamed, Salim
    Douek, Philippe
    Sigovan, Monica
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 61 - 67
  • [6] Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods
    Chen, Baiyu
    Christianson, Olav
    Wilson, Joshua M.
    Samei, Ehsan
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [7] Heavily Calcified Coronary Arteries Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography
    De Santis, Domenico
    Jin, Kwang Nam
    Schoepf, U. Joseph
    Grant, Katharine L.
    De Cecco, Carlo N.
    Nance, John W., Jr.
    Vogl, Thomas J.
    Laghi, Andrea
    Albrecht, Moritz H.
    [J]. INVESTIGATIVE RADIOLOGY, 2018, 53 (02) : 103 - 109
  • [8] Photon-counting CT review
    Flohr, Thomas
    Petersilka, Martin
    Henning, Andre
    Ulzheimer, Stefan
    Ferda, Jiri
    Schmidt, Bernhard
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 126 - 136
  • [9] Characterization of a Novel Hafnium-Based X-ray Contrast Agent
    Frenzel, Thomas
    Bauser, Marcus
    Berger, Markus
    Hilger, Christoph Stephan
    Hegele-Hartung, Christa
    Jost, Gregor
    Neis, Christian
    Hegetschweiler, Kaspar
    Riefke, Bjoern
    Suelzle, Detlev
    Pietsch, Hubertus
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (12) : 776 - 785
  • [10] Assessment of candidate elements for development of spectral photon-counting CT specific contrast agents
    Kim, Johoon
    Bar-Ness, Daniel
    Si-Mohamed, Salim
    Coulon, Philippe
    Blevis, Ira
    Douek, Philippe
    Cormode, David P.
    [J]. SCIENTIFIC REPORTS, 2018, 8