Measurement of Regional 2D Gas Transport Efficiency in Rabbit Lung Using Hyperpolarized 129Xe MRI

被引:5
作者
Ruppert, Kai [1 ]
Xin, Yi [1 ,2 ]
Hamedani, Hooman [1 ,2 ]
Amzajerdian, Faraz [1 ,2 ]
Loza, Luis [1 ]
Achekzai, Tahmina [1 ]
Duncan, Ian F. [1 ]
Profka, Harrilla [1 ]
Siddiqui, Sarmad [1 ,2 ]
Pourfathi, Mehrdad [1 ,3 ]
Sertic, Federico [1 ]
Cereda, Maurizio F. [4 ]
Kadlecek, Stephen [1 ]
Rizi, Rahim R. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Elect & Syst Engn, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
关键词
PULMONARY PERFUSION; XE-129; EXCHANGE; SPECTROSCOPY; VENTILATION; NMR;
D O I
10.1038/s41598-019-38942-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
While hyperpolarized xenon-129 (HXe) MRI offers a wide array of tools for assessing functional aspects of the lung, existing techniques provide only limited quantitative information about the impact of an observed pathology on overall lung function. By selectively destroying the alveolar HXe gas phase magnetization in a volume of interest and monitoring the subsequent decrease in the signal from xenon dissolved in the blood inside the left ventricle of the heart, it is possible to directly measure the contribution of that saturated lung volume to the gas transport capacity of the entire lung. In mechanically ventilated rabbits, we found that both xenon gas transport and transport efficiency exhibited a gravitation-induced anterior-to-posterior gradient that disappeared or reversed direction, respectively, when the animal was turned from supine to prone position. Further, posterior ventilation defects secondary to acute lung injury could be re-inflated by applying positive end expiratory pressure, although at the expense of decreased gas transport efficiency in the anterior volumes. These findings suggest that our technique might prove highly valuable for evaluating lung transplants and lung resections, and could improve our understanding of optimal mechanical ventilator settings in acute lung injury.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] MRI of stroke using hyperpolarized 129Xe
    Zhou, Xin
    Sun, Yanping
    Mazzanti, Mary
    Henninger, Nils
    Mansour, Joey
    Fisher, Marc
    Albert, Mitchell
    NMR IN BIOMEDICINE, 2011, 24 (02) : 170 - 175
  • [2] Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral
    Bdaiwi, Abdullah S.
    Willmering, Matthew M.
    Wang, Hui
    Cleveland, Zackary, I
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1342 - 1356
  • [3] Using hyperpolarized 129Xe MRI to quantify regional gas transfer in idiopathic pulmonary fibrosis
    Wang, Jennifer M.
    Robertson, Scott H.
    Wang, Ziyi
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Smigla, Rose Marie
    O'Riordan, Thomas G.
    Sundy, John
    Ebner, Lukas
    Rackley, Craig R.
    McAdams, Page
    Driehuys, Bastiaan
    THORAX, 2018, 73 (01) : 21 - 28
  • [4] Hyperpolarized 129Xe Imaging of the Rat Lung using Spiral IDEAL
    Doganay, Ozkan
    Wade, Trevor
    Hegarty, Elaine
    McKenzie, Charles
    Schulte, Rolf F.
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 566 - 576
  • [5] Quantitative analysis of hyperpolarized 129Xe gas transfer MRI
    Wang, Ziyi
    Robertson, Scott Haile
    Wang, Jennifer
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Bier, Elianna A.
    Rajagopal, Sudarshan
    Huang, Yuh Chin
    O'Riordan, Thomas G.
    Rackley, Craig R.
    McAdams, H. Page
    Driehuys, Bastiaan
    MEDICAL PHYSICS, 2017, 44 (06) : 2415 - 2428
  • [6] Regional ventilation mapping of the rat lung using hyperpolarized 129Xe magnetic resonance imaging
    Couch, Marcus J.
    Ouriadov, Alexei
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1623 - 1631
  • [7] Rapid assessment of pulmonary gas transport with hyperpolarized 129Xe MRI using a 3D radial double golden-means acquisition with variable flip angles
    Ruppert, Kai
    Amzajerdian, Faraz
    Hamedani, Hooman
    Xin, Yi
    Loza, Luis
    Achekzai, Tahmina
    Duncan, Ian F.
    Profka, Harrilla
    Siddiqui, Sarmad
    Pourfathi, Mehrdad
    Cereda, Maurizio F.
    Kadlecek, Stephen
    Rizi, Rahim R.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2439 - 2448
  • [8] Quantification of Human Lung Structure and Physiology Using Hyperpolarized 129Xe
    Chang, Yulin V.
    Quirk, James D.
    Ruset, Iulian C.
    Atkinson, Jeffrey J.
    Hersman, F. William
    Woods, Jason C.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 339 - 344
  • [9] MOXE: A model of gas exchange for hyperpolarized 129Xe magnetic resonance of the lung
    Chang, Yulin V.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 884 - 890
  • [10] Using hyperpolarized 129Xe gas-exchange MRI to model the regional airspace, membrane, and capillary contributions to diffusing capacity
    Wang, Ziyi
    Rankine, Leith
    Bier, Elianna A.
    Mummy, David
    Lu, Junlan
    Church, Alex
    Tighe, Robert M.
    Swaminathan, Aparna
    Huang, Yuh-Chin T.
    Que, Loretta G.
    Mammarappallil, Joseph G.
    Rajagopal, Sudarshan
    Driehuys, Bastiaan
    JOURNAL OF APPLIED PHYSIOLOGY, 2021, 130 (05) : 1398 - 1409