Fluorescent immersion range scanning

被引:54
作者
Hullin, Matthias B. [1 ]
Fuchs, Martin [1 ]
Ihrke, Ivo [1 ]
Seidel, Hans-Peter [1 ]
Lensch, Hendrik P. A. [1 ]
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
来源
ACM TRANSACTIONS ON GRAPHICS | 2008年 / 27卷 / 03期
关键词
3D scanning; transparent surfaces; fluorescent dye;
D O I
10.1145/1360612.1360686
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
The quality of a 3D range scan should not depend on the surface properties of the object. Most active range scanning techniques, however, assume a diffuse reflector to allow for a robust detection of incident light patterns. In our approach we embed the object into a fluorescent liquid. By analyzing the light rays that become visible due to fluorescence rather than analyzing their reflections off the surface, we can detect the intersection points between the projected laser sheet and the object surface for a wide range of different materials. For transparent objects we can even directly depict a slice through the object in just one image by matching its refractive index to the one of the embedding liquid. This enables a direct sampling of the object geometry without the need for computational reconstruction. This way, a high-resolution 3D volume can be assembled simply by sweeping a laser plane through the object. We demonstrate the effectiveness of our light sheet range scanning approach on a set of objects manufactured from a variety of materials and material mixes, including dark, translucent and transparent objects.
引用
收藏
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 2004, P XXTH INT SOC PHOT
[2]  
Ben-Ezra M, 2003, NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, P1025
[3]   Review of 20 years of range sensor development [J].
Blais, F .
JOURNAL OF ELECTRONIC IMAGING, 2004, 13 (01) :231-243
[4]  
Chen T., 2006, P IEEE COMP SOC C CO, P17
[5]   Quantitative measurements of released amines from individual exocytosis events [J].
Clark, RA ;
Ewing, AG .
MOLECULAR NEUROBIOLOGY, 1997, 15 (01) :1-16
[6]  
CURLESS B, 1995, FIFTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, PROCEEDINGS, P987, DOI 10.1109/ICCV.1995.466772
[7]  
Davis JE, 2005, IEEE I CONF COMP VIS, P436
[8]   Time resolved 3D passive scalar concentration-field imaging by laser induced fluorescence (LIF) in moving liquids [J].
Deusch, S ;
Dracos, T .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (02) :188-200
[9]   Density estimation for dynamic volumes [J].
Fuchs, Christian ;
Chen, Tongbo ;
Goesele, Michael ;
Theisel, Holger ;
Seidel, Hans-Peter .
COMPUTERS & GRAPHICS-UK, 2007, 31 (02) :205-211
[10]  
GRAZ T, DATABASE FLUORESCENT