Long-Term Efficacy of Biodegradable Metal-Polymer Composite Stents After the First and the Second Implantations into Porcine Coronary Arteries

被引:65
作者
Li, Xin [4 ]
Zhang, Wanqian [2 ,3 ,4 ]
Lin, Wenjiao [2 ,3 ]
Qiu, Hong [1 ]
Qi, Yongli [4 ]
Ma, Xun [4 ]
Qi, Haiping [2 ,3 ]
He, Yao [4 ]
Zhang, Hongjie [4 ]
Qian, Jie [1 ]
Zhang, Gui [2 ,3 ]
Gao, Runlin [1 ]
Zhang, Deyuan [2 ,3 ]
Ding, Jiandong [4 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Fu Wai Hosp, Natl Ctr Cardiovasc Dis, Dept Cardiol, Beijing 100037, Peoples R China
[2] Lifetech Sci Shenzhen Co Ltd, R&D Ctr, Shenzhen 518057, Peoples R China
[3] Biotyx Med Shenzhen Co Ltd, R&D Ctr, Shenzhen 518109, Peoples R China
[4] Fudan Univ, Dept Macromol Sci, State Key Lab Mol Engn Polymers, Shanghai 200438, Peoples R China
基金
美国国家科学基金会; 国家重点研发计划;
关键词
biodegradable coronary stent; surface coating; metal-polymer composite stent; polylactide; porcine artery model; cardiovascular disease; BIORESORBABLE SCAFFOLD; BALLOON ANGIOPLASTY; BLOCK-COPOLYMERS; STRUT THICKNESS; ELUTING STENTS; IRON; BIOCOMPATIBILITY; RESTENOSIS; SURFACE; ALLOY;
D O I
10.1021/acsami.0c00971
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A biodegradable coronary stent is expected to eliminate the adverse events of an otherwise eternally implanting material after vessel remodeling. Both biocorrodible metals and biodegradable polymers have been tried as the matrix of the new-generation stent. Herein, we utilized a metal-polymer composite material to combine the advantages of the high mechanical strength of metals and the adjustable degradation rate of polymers to prepare the biodegradable stent. After coating polylactide (PLA) on the surface of iron, the degradation of iron was accelerated significantly owing to the decrease of local pH resulting from the hydrolysis of PLA, etc. We implanted the metal-polymer composite stent (MPS) into the porcine artery and examined its degradation in vivo, with the corresponding metal-based stent (MBS) as a control. Microcomputed tomography (micro-CT), coronary angiography (CA), and optical coherence tomography (OCT) were performed to observe the stents and vessels during the animal experiments. The MPS exhibited faster degradation than MBS, and the inflammatory response of MPS was acceptable 12 months after implantation. Additionally, we implanted another MPS after 1-year implantation of the first MPS to investigate the result of the MPS in the second implantation. The feasibility of the biodegradable MPS in second implantation in mammals was also confirmed.
引用
收藏
页码:15703 / 15715
页数:13
相关论文
共 71 条
[1]   Multiplicity of morphologies in poly (L-lactide) bioresorbable vascular scaffolds [J].
Ailianou, Artemis ;
Ramachandran, Karthik ;
Kossuth, Mary Beth ;
Oberhauser, James Paul ;
Kornfield, Julia A. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2016, 113 (42) :11670-11675
[2]   Medical progress: Disorders of iron metabolism [J].
Andrews, NC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (26) :1986-1995
[3]   Bioresorbable stents: Current and upcoming bioresorbable technologies [J].
Ang, Hui Ying ;
Bulluck, Heerajnarain ;
Wong, Philip ;
Venkatraman, Subbu S. ;
Huang, Yingying ;
Foin, Nicolas .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 :931-939
[4]  
Antoniucci D, 2000, CATHETER CARDIO INTE, V49, P376, DOI 10.1002/(SICI)1522-726X(200004)49:4<376::AID-CCD5>3.0.CO
[5]  
2-O
[6]   Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating [J].
Artzi, Natalie ;
Tzafriri, Abraham R. ;
Faucher, Keith M. ;
Moodie, Geoffrey ;
Albergo, Theresa ;
Conroy, Suzanne ;
Corbeil, Scott ;
Martakos, Paul ;
Virmani, Renu ;
Edelman, Elazer R. .
ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (02) :276-286
[7]  
Artzi N, 2011, NAT MATER, V10, P704, DOI [10.1038/NMAT3095, 10.1038/nmat3095]
[8]  
Bauters C, 1998, CIRCULATION, V97, P318
[9]   Effect of minor content of Gd on the mechanical and degradable properties of as-cast Mg-2Zn-xGd-0.5Zr alloys [J].
Chen, Junxiu ;
Tan, Lili ;
Yu, Xiaoming ;
Yang, Ke .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2019, 35 (04) :503-511
[10]   Multilayered coating of titanium implants promotes coupled osteogenesis and angiogenesis in vitro and in vivo [J].
Chen, Weizhen ;
Xu, Kui ;
Tao, Bailong ;
Dai, Liangliang ;
Yu, Yonglin ;
Mu, Caiyun ;
Shen, Xinkun ;
Hu, Yan ;
He, Ye ;
Cai, Kaiyong .
ACTA BIOMATERIALIA, 2018, 74 :489-504