Free amino acid quantification by LC-MS/MS using derivatization generated isotope-labelled standards

被引:36
作者
Johnson, David W. [1 ,2 ]
机构
[1] Womens & Childrens Hosp, Dept Med Genet, SA Pathol, Adelaide, SA 5006, Australia
[2] Univ Adelaide, Dept Pediat, Adelaide, SA 5005, Australia
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 17-18期
关键词
Amino acids; Derivatization; Tandem mass spectrometry; Succinimide esters; Isotope labelling; REAGENT;
D O I
10.1016/j.jchromb.2010.12.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The further development of derivatizing reagents for plasma amino acid quantification by tandem mass spectrometry is described. The succinimide ester of 4-methylpiperazineacetic acid (MPAS), the iTRAQ reagent, was systematically modified to improve tandem mass spectrometer (MS/MS) product ion intensity. 4-Methylpiperazinebutyryl succinimide (MPBS) and dimethylaminobutyryl succinimide (DMABS) afforded one to two orders of magnitude greater MS/MS product ion signal intensity than the MPAS derivative for simple amino acids. CD3 analogues of the modified derivatizing reagents were evaluated for preparation of amino acid isotope-labelled quantifying standards. Acceptable accuracy and precision was obtained with d(3)-DMABS as the amino acid standards derivatizing reagent. The product ion spectra of the DMABS amino acid derivatives are diagnostic for structural isomers including valine/norvaline, alanine/sarcosine and leucine/isoleucine. Improved analytical sensitivity and specificity afforded by these derivatives may help to establish liquid chromatography tandem mass spectrometry (LC-MS/MS) with derivatization generated isotope-labelled standards a viable alternative to amino acids analysers. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1345 / 1352
页数:8
相关论文
共 12 条
[1]  
DEY S, 2005, Patent No. 20050148771
[2]  
HAMON C, 2007, Patent No. 20070023628
[3]   A modified Girard derivatizing reagent for universal profiling and trace analysis of aldehydes and ketones by electrospray ionization tandem mass spectrometry [J].
Johnson, David W. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) :2926-2932
[4]  
Johnson DW, 2000, RAPID COMMUN MASS SP, V14, P2019, DOI 10.1002/1097-0231(20001115)14:21<2019::AID-RCM121>3.0.CO
[5]  
2-2
[6]   Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique [J].
Kawana, Shuichi ;
Nakagawa, Katsuhiro ;
Hasegawa, Yuki ;
Yamaguchi, Seiji .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30) :3113-3118
[7]   Multiple Isotopic Labels for Quantitative Mass Spectrometry [J].
Morano, Cain ;
Zhang, Xin ;
Fricker, Lloyd D. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9298-9309
[8]   Second-tier test for quantification of alloisoleucine and branched-chain amino acids in dried blood spots to improve newborn screening for maple syrup urine disease (MSUD) [J].
Oglesbee, Devin ;
Sanders, Karen A. ;
Lacey, Jean M. ;
Magera, Mark J. ;
Casetta, Bruno ;
Strauss, Kevin A. ;
Tortorelli, Silvia ;
Rinaldo, Piero ;
Matern, Dietrich .
CLINICAL CHEMISTRY, 2008, 54 (03) :542-549
[9]   Quantitative amino acid analysis using a Beckman system gold HPLC 126AA analyzer [J].
Qu, Y ;
Slocum, RH ;
Fu, J ;
Rasmussen, WE ;
Rector, HD ;
Miller, JB ;
Coldwell, JG .
CLINICA CHIMICA ACTA, 2001, 312 (1-2) :153-162
[10]   Quantification of glutamine in dried blood spots and plasma by tandem mass spectrometry for the biochemical diagnosis and monitoring of ornithine transcarbamylase deficiency [J].
Trinh, MU ;
Blake, J ;
Harrison, JR ;
Gerace, R ;
Ranieri, E ;
Fletcher, JM ;
Johnson, DW .
CLINICAL CHEMISTRY, 2003, 49 (04) :681-684