Development of combination tapered fiber-optic biosensor dip probe for quantitative estimation of interleukin-6 in serum samples

被引:11
|
作者
Wang, Chun Wei [1 ]
Manne, Upender [2 ]
Reddy, Vishnu B. [2 ]
Oelschlager, Denise K. [2 ]
Katkoori, Venkat R. [2 ]
Grizzle, William E. [2 ]
Kapoor, Rakesh [1 ]
机构
[1] Univ Alabama Birmingham, Dept Phys, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Pathol, Birmingham, AL 35294 USA
关键词
biosensor; fiber-optic; evanescent wave; interleukin; fluorescence; cytokine; charged coupled device; STAPHYLOCOCCAL-ENTEROTOXIN-B; OPTIC BIOSENSOR; IMMUNOSENSOR;
D O I
10.1117/1.3523368
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A combination tapered fiber-optic biosensor (CTFOB) dip probe for rapid and cost-effective quantification of proteins in serum samples has been developed. This device relies on diode laser excitation and a charged-coupled device spectrometer and functions on a technique of sandwich immunoassay. As a proof of principle, this technique was applied in a quantitative estimation of interleukin IL-6. The probes detected IL-6 at picomolar levels in serum samples obtained from a patient with lupus, an autoimmune disease, and a patient with lymphoma. The estimated concentration of IL-6 in the lupus sample was 5.9 +/- 0.6 pM, and in the lymphoma sample, it was below the detection limit. These concentrations were verified by a procedure involving bead-based xMAP technology. A similar trend in the concentrations was observed. The specificity of the CTFOB dip probes was assessed by analysis with receiver operating characteristics. This analysis suggests that the dip probes can detect 5-pM or higher concentration of IL-6 in these samples with specificities of 100%. The results provide information for guiding further studies in the utilization of these probes to quantify other analytes in body fluids with high specificity and sensitivity. (C) 2010 Society of Photo-Optical Instrumentation Engineers, [DOI: 10.1117/1.3523368]
引用
收藏
页数:7
相关论文
共 12 条
  • [1] Development of combination tapered fiber-optic biosensor dip probe for quantitative estimation of interleukin-6 in serum samples (vol 15, 067005, 2010)
    Wang, Chun Wei
    Manne, Upender
    Reddy, Vishnu B.
    Oelschlager, Denise K.
    Katkoori, Venkat R.
    Grizzle, William E.
    Kapoor, Rakesh
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
  • [2] Highly specific detection of interleukin-6 (IL-6) protein using combination tapered fiber-optic biosensor dip-probe
    Kapoor, Rakesh
    Wang, Chun-Wei
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2696 - 2701
  • [3] Quantitative Estimation of IL-6 in Serum/Plasma Samples Using a Rapid and Cost-Effective Fiber-Optic dip-probe
    Wang, Chun Wei
    Manne, Upender
    Reddy, Vishnu B.
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [4] Highly specific detection of IL-8 protein using combination tapered fiber-optic biosensor dip-probe
    Wang, Chun-Wei
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [5] Dissociation constant measurement using combination tapered fiber-optic biosensor (CTFOB) dip-probes
    Wang, Chun-Wei
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [6] Free cholesterol fiber-optic biosensor for serum samples with simplex optimization
    Marazuela, MD
    Cuesta, B
    MorenoBondi, MC
    Quejido, A
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (03): : 233 - 240
  • [7] Real-time association rate constant measurement using combination tapered fiber-optic biosensor (CTFOB) dip-probes
    Simmonds, Boris
    Wang, Chun-Wei
    Kapoor, Rakesh
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X, 2010, 7559
  • [8] Development of fiber-optic surface plasmon resonance sensor based on tapered structure probe
    Feng Li-Hang
    Zeng Jie
    Liang Da-Kai
    Zhang Wei-Gong
    ACTA PHYSICA SINICA, 2013, 62 (12)
  • [9] Serum albumin measurement using a tapered fluorescent fiber-optic evanescent wave-based biosensor
    Preejith, Pv
    Lim, Cs
    Chia, Tf
    2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2, 2006, : 388 - +
  • [10] Development of quantum dot-based fluorescence lateral flow immunoassay strip for rapid and quantitative detection of serum interleukin-6
    Tang, Jinsong
    Wu, Lili
    Lin, Jingtao
    Zhang, Erying
    Luo, Yong
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (05)