Activities of daily living after total hip arthroplasty. Is a 32-mm femoral head superior to a 26-mm head for improving daily activities?

被引:16
作者
Matsushita, Isao [1 ]
Morita, Yuji [2 ]
Ito, Yoshiaki [1 ]
Gejo, Ryuichi [1 ]
Kimura, Tomoatsu [1 ]
机构
[1] Toyama Univ, Toyama 930, Japan
[2] Tokyo Womans Med Univ, Tokyo, Japan
关键词
POLYETHYLENE WEAR; 32; MM; MOTION; RANGE; REPLACEMENT; COMPONENTS;
D O I
10.1007/s00264-009-0909-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Range of motion (ROM) of the hip joint after total hip arthroplasty (THA) could be increased by using a larger prosthetic femoral head, but it is not known whether the activities of daily living (ADL) are influenced by THA with different head sizes. Our objective was to compare postoperative ADL in patients who underwent THA using a head diameter of 26 mm or 32 mm. We assessed the range of motion and the mode of ADL after cementless primary THA. Comparison was performed between 25 joints of 24 patients who underwent THA with a 26-mm femoral head (26-mm group) and 24 joints of 20 patients with a 32-mm head (32-mm group). The postoperative range of flexion and abduction was significantly larger in the 32-mm group than in the 26-mm group. With respect to the mode of performing selected ADL such as putting on and removing pants, socks, and cutting toenails, many patients adopted the compensatory position of lumbar flexion with hip flexion plus knee extension in the 26-mm group, while a majority of the patients from the 32-mm group employed the mode of hip flexion with knee flexion. Patients with the 32-mm head showed better postoperative ADL of the ipsilateral side compared with the 26-mm head.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 15 条
[1]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[2]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]   Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm - A prospective randomised study [J].
Eggli, S ;
z'Brun, S ;
Gerber, C ;
Ganz, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (03) :447-451
[4]   Large diameter femoral heads on highly cross-finked polyethylene - Minimum 3-year results [J].
Geller, Jeffrey A. ;
Malchau, Henrik ;
Bragdon, Charles ;
Greene, Meridith ;
Harris, William H. ;
Freiberg, Andrew A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) :53-59
[5]  
HARRIS WH, 1995, CLIN ORTHOP RELAT R, P46
[6]   Intracapsular components do not change hip proprioception [J].
Ishii, Y ;
Tojo, T ;
Terajima, K ;
Terashima, S ;
Bechtold, JE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (02) :345-348
[7]  
JOHNSTON RC, 1970, CLIN ORTHOP RELAT R, P205
[8]   Polyethylene wear in Scanhip(R) arthroplasty with a 22 or 32 mm head - 62 matched patients followed for 7-9 years [J].
Kesteris, U ;
Ilchmann, T ;
Wingstrand, H ;
Onnerfalt, R .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :125-127
[9]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[10]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528