A Study on the Possibility of Measuring the Non-contact Galvanic Skin Response Based on Near-Infrared Imaging

被引:0
|
作者
Jo, Geumbi [1 ]
Lee, Seunggeon [2 ]
Lee, Eui Chul [3 ]
机构
[1] Sangmyung Univ, Grad Sch, Dept Comp Sci, Seoul, South Korea
[2] Sangmyung Univ, Grad Sch, Dept AI & Informat, Seoul, South Korea
[3] Sangmyung Univ, Dept Human Ctr AI, Seoul, South Korea
来源
INTELLIGENT HUMAN COMPUTER INTERACTION, PT I | 2021年 / 12615卷
基金
新加坡国家研究基金会;
关键词
Bio-signal; Galvanic Skin Response (GSR); Non-contact; Image processing; Near-infrared camera;
D O I
10.1007/978-3-030-68449-5_12
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Galvanic skin response (GSR) is the change in the electrical conduction of the skin caused by an emotional response to a stimulus. This bio-signal appears to be the action of the autonomic nervous system as a change in sweat gland activity and reflects the intensity of emotion. There have been various technologies for detecting autonomic nerve reactions to bio-signals in image processing; research on non-contact detection of these technologies has become amajor issue. However, research onGSRfor detecting signals in a non-contactmethod is lacking compared to other bio-signals. In this paper, we propose a non-contact GSR detectionmethod from the human face region using a near-infrared camera. The proposed method used a 20-min visual stimulus video that caused tension or excitement among the participants and set up an isolated experimental environment to minimize emotion induction caused by external factors. Afterward, a GSR sensor was attached to the inside of the participant's finger, and a visual stimulus video was shown. The participant's face region was shot using a near-infrared camera, which also stored GSR sensor data and infrared face images that were input during the experiment. The face region was detected from the acquired face images, and the region of interest inside the face was compared with the data obtained through the GSR sensor. Finally, the correlation between the image intensities inside the designated region of interest and the data from the GSR sensor were analyzed.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 37 条
  • [21] Deep-hole inner diameter measuring system based on non-contact capacitance sensor
    Yu Y.
    Zhang H.
    Wang Z.
    Chang Y.
    Transactions of Tianjin University, 2010, 16 (6) : 447 - 451
  • [22] Image-Based Non-Contact Monitoring of Skin Texture Changed by Piloerection for Emotion Estimation
    Uchida, Mihiro
    Akaho, Rina
    Ogawa, Keiko
    Tsumura, Norimichi
    OPTICAL DIAGNOSTICS AND SENSING XVIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2018, 10501
  • [23] Research on non-contact infrared imaging technique for multilayer storage identification of oil tanks based on an improved edge-detection algorithm
    Wei, Yao-Yu
    Chen, Hong-Wei
    Li, Yang
    Guo, Yu-Jun
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2025,
  • [24] Nanosecond Pulse Near-field Sensing based Non-contact Physiological Signals Measurement
    Lin, Hong-Dun
    Lee, Yen-Shien
    Su, Yu-Jen
    Chuang, Bor-Nian
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 1214 - 1219
  • [25] Study of the Ballistocardiogram signal in non-contact life detection system based on radar
    Wang, Jianqi
    Lu, Guohua
    Jing, Xijing
    Zhang, Yang
    Lv, Hao
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 594 - 597
  • [26] Development of an ice shape non-contact measuring system based on 3D scanning technology
    Guo, L.
    Ma, J.
    Li, M.
    Manufacturing and Engineering Technology, 2015, : 455 - 459
  • [27] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Lalit Maurya
    Reyer Zwiggelaar
    Deepak Chawla
    Prasant Mahapatra
    Journal of Clinical Monitoring and Computing, 2023, 37 : 815 - 828
  • [28] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Maurya, Lalit
    Zwiggelaar, Reyer
    Chawla, Deepak
    Mahapatra, Prasant
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (03) : 815 - 828
  • [29] Quality Control Method Based on Gear Tooth Contact Evaluation Using Near-Infrared Ray Imagery
    Nagata, Masaki
    Hirogaki, Toshiki
    Aoyama, Eiichi
    Iida, Takahiro
    Uenishi, Yasuhiro
    Matsubara, Masami
    Usui, Yoshitaka
    ADVANCED PRECISION ENGINEERING, 2010, 447-448 : 569 - +
  • [30] Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving
    Mateu-Mateus, Marc
    Guede-Fernandez, Federico
    Garcia-Gonzalez, Miguel A.
    Ramos-Castro, Juan
    Fernandez-Chimeno, Mireya
    IEEE ACCESS, 2019, 7 : 152522 - 152532