A Study on the Possibility of Measuring the Non-contact Galvanic Skin Response Based on Near-Infrared Imaging

被引:0
|
作者
Jo, Geumbi [1 ]
Lee, Seunggeon [2 ]
Lee, Eui Chul [3 ]
机构
[1] Sangmyung Univ, Grad Sch, Dept Comp Sci, Seoul, South Korea
[2] Sangmyung Univ, Grad Sch, Dept AI & Informat, Seoul, South Korea
[3] Sangmyung Univ, Dept Human Ctr AI, Seoul, South Korea
来源
INTELLIGENT HUMAN COMPUTER INTERACTION, PT I | 2021年 / 12615卷
基金
新加坡国家研究基金会;
关键词
Bio-signal; Galvanic Skin Response (GSR); Non-contact; Image processing; Near-infrared camera;
D O I
10.1007/978-3-030-68449-5_12
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Galvanic skin response (GSR) is the change in the electrical conduction of the skin caused by an emotional response to a stimulus. This bio-signal appears to be the action of the autonomic nervous system as a change in sweat gland activity and reflects the intensity of emotion. There have been various technologies for detecting autonomic nerve reactions to bio-signals in image processing; research on non-contact detection of these technologies has become amajor issue. However, research onGSRfor detecting signals in a non-contactmethod is lacking compared to other bio-signals. In this paper, we propose a non-contact GSR detectionmethod from the human face region using a near-infrared camera. The proposed method used a 20-min visual stimulus video that caused tension or excitement among the participants and set up an isolated experimental environment to minimize emotion induction caused by external factors. Afterward, a GSR sensor was attached to the inside of the participant's finger, and a visual stimulus video was shown. The participant's face region was shot using a near-infrared camera, which also stored GSR sensor data and infrared face images that were input during the experiment. The face region was detected from the acquired face images, and the region of interest inside the face was compared with the data obtained through the GSR sensor. Finally, the correlation between the image intensities inside the designated region of interest and the data from the GSR sensor were analyzed.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 37 条
  • [1] In vivo detection of atherosclerotic plaque using non-contact and label-free near-infrared hyperspectral imaging
    Chihara, Hideo
    Oishi, Naoya
    Ishii, Akira
    Munemitsu, Toshihiro
    Arai, Daisuke
    Ikeda, Hiroyuki
    Miyamoto, Susumu
    ATHEROSCLEROSIS, 2016, 250 : 106 - 113
  • [2] MODELING AND VALIDATION OF LIGHT PROPAGATION IN FREE-SPACE FOR NON-CONTACT NEAR-INFRARED FLUORESCENT TOMOGRAPHY
    Yao Jun-Jie
    Hu Gang
    Bai Jing
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2008, 27 (05) : 330 - +
  • [3] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [4] Near-infrared spectroscopy system with non-contact source and detector for in vivo multi-distance measurement of deep biological tissue
    Funane, Tsukasa
    Atsumori, Hirokazu
    Kiguchi, Masashi
    Tanikawa, Yukari
    Okada, Eiji
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE X, 2013, 8578
  • [5] Characterization of a non-contact imaging scintillator-based dosimetry system for total skin electron therapy
    Tendler, Irwin I.
    Bruza, Petr
    Jermyn, Mike
    Cao, Xu
    Williams, Benjamin B.
    Jarvis, Lesley A.
    Pogue, Brian W.
    Gladstone, David J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12)
  • [6] Non-contact Continuous Blood Pressure Measurement Based on Imaging Equipment
    Guo, Ying
    Liu, Xiaohua
    Kong, Lingqin
    Liu, Ming
    Zhao, Yuejin
    Dong, Liquan
    2019 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING/SPECTROSCOPY AND SIGNAL PROCESSING TECHNOLOGY, 2020, 11438
  • [7] Non-contact pulse wave extraction based on imaging and matrix processing
    Tian, Ke
    Liu, Gang
    Gong, Cheng
    OPTIK, 2019, 193
  • [8] Near-Infrared Absorption Imaging and Processing Technologies Based on Gold Nanorods
    LI Qian
    HUANG Hao
    LI Zhe
    CHEN Ming
    YU Xuefeng
    WuhanUniversityJournalofNaturalSciences, 2013, 18 (04) : 307 - 312
  • [9] Non-contact detection of cardiac rate based on visible light imaging device
    Zhu, Huishi
    Zhao, Yuejin
    Dong, Liquan
    OPTICS AND PHOTONICS FOR INFORMATION PROCESSING VI, 2012, 8498
  • [10] Non-contact heart rate and respiratory monitoring based on Imaging Photoplethysmography at fingertip
    Qiao WenLong
    Zhou Liang
    Liu Zhaohui
    Yu Jiangjun
    Sun Xiaoxiao
    AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS, 2020, 11566