Nail thickness measurements using optical coherence tomography and 20-MHz ultrasonography

被引:53
作者
Mogensen, M.
Thomsen, J. B.
Skovgaard, L. T.
Jemec, G. B. E.
机构
[1] Roskilde Hosp, Dept Dermatol, DK-4000 Roskilde, Denmark
[2] Tech Univ Denmark, Risoe Natl Lab, Opt & Plasma Res Dept, Roskilde, Denmark
[3] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
nail imaging; nail thickness; optical coherence tomography; ultrasound;
D O I
10.1111/j.1365-2133.2007.08118.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Nail diseases are often troubling to the patient and may present a diagnostic challenge to the dermatologist. Biopsies from the nail may be required although often perceived uncomfortable by the patient and potentially scarring. Noninvasive technologies are therefore of particular interest in the study of nails. Optical coherence tomography (OCT) is an optical imaging modality which may provide improved data. Objectives This study evaluates nail morphology and thickness in OCT images in comparison with high-frequency ultrasound (HFUS) imaging of the nail. Methods Ten healthy volunteers were recruited for imaging and nail measurements; OCT and HFUS images were compared qualitatively. Nail thickness measurements with four different techniques were compared: ultrasound, OCT, polarization-sensitive (PS) OCT and callipers. The OCT system was developed at Risoe National Laboratory, Denmark. A commercially available 20-MHz ultrasound system (Dermascan; Cortex Technology, Hadsund, Denmark) was used. Results In standard OCT the nail plate appeared as a layered structure containing a varying number of horizontal homogeneous bands of varying intensity and thickness. PS-OCT images of the nail plate also showed a layered structure. The refractive index of the nail was 1.47 +/- 0.09. OCT and PS-OCT had low coefficients of variation, 6.31 and 6.53, respectively, compared with other methods: HFUS 12.70 and callipers 14.03. Conclusions PS-OCT has to our knowledge not been applied to OCT analysis of the nail, and offers some advantages in separation of the nail bed from the nail plate.
引用
收藏
页码:894 / 900
页数:7
相关论文
共 39 条
[1]   Evaluating central corneal thickness measurements with noncontact optical low-coherence reflectometry and contact ultrasound pachymetry [J].
Airiani, Suzanna ;
Trokel, Stephen L. ;
Lee, Shing M. ;
Braunstein, Richard E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (01) :164-165
[2]   The use of ultrasonography in preoperative localization of digital glomus tumors [J].
Chen, SHT ;
Chen, YL ;
Cheng, MH ;
Yeow, KM ;
Chen, HC ;
Wei, FC .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 112 (01) :115-119
[3]  
DEBERKER D, 2006, HDB NONINVASIVE METH, P911
[4]  
Drape Jean-Luc, 2004, Clin Podiatr Med Surg, V21, P493, DOI 10.1016/j.cpm.2004.05.012
[5]   Imaging of the tumors of the perionychium [J].
Drapé, JL .
HAND CLINICS, 2002, 18 (04) :655-+
[6]   ULTRASOUND VELOCITY IN HUMAN FINGERNAIL AND EFFECTS OF HYDRATION - VALIDATION OF INVIVO NAIL THICKNESS MEASUREMENT TECHNIQUES [J].
FINLAY, AY ;
WESTERN, B ;
EDWARDS, C .
BRITISH JOURNAL OF DERMATOLOGY, 1990, 123 (03) :365-373
[7]   ULTRASOUND TRANSMISSION TIME - AN INVIVO GUIDE TO NAIL THICKNESS [J].
FINLAY, AY ;
MOSELEY, H ;
DUGGAN, TC .
BRITISH JOURNAL OF DERMATOLOGY, 1987, 117 (06) :765-770
[8]   Optical coherence tomography for ultrahigh resolution in vivo imaging [J].
Fujimoto, JG .
NATURE BIOTECHNOLOGY, 2003, 21 (11) :1361-1367
[9]   Applications of optical coherence tomography in dermatology [J].
Gambichler, T ;
Moussa, G ;
Sand, M ;
Sand, D ;
Altmeyer, P ;
Hoffmann, K .
JOURNAL OF DERMATOLOGICAL SCIENCE, 2005, 40 (02) :85-94
[10]   Comparison of optical low-coherence reflectometry and ultrasound pachymetry in measuring corneal graft thickness [J].
Gaujoux, Thomas ;
Borderie, Vincent M. ;
Yousfi, Hakim ;
Bourcier, Tristan ;
Touzeau, Olivier ;
Laroche, Laurent .
CORNEA, 2007, 26 (02) :185-189