Influence of Smoothing on Voxel-Based Mesh Accuracy in Micro-Finite Element

被引:7
作者
Bardyn, Thibaut [1 ]
Reyes, Mauricio [1 ]
Larrea, Xabier [1 ]
Buechler, Philippe [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, Bern, Switzerland
来源
COMPUTATIONAL BIOMECHANICS FOR MEDICINE | 2010年
关键词
Finite element; Meshing; Smoothing; Validation; Microfocus CT; GENERATION;
D O I
10.1007/978-1-4419-5874-7_10
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CT (mu CT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 mu m) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young's moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 mu m resolutions. Improvements were not significant for the 64 mu m, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [11] Comparing Isotropic and Anisotropic Smoothing for Voxel-Based DTI Analyses: A Simulation Study
    Van Hecke, Wim
    Leemans, Alexander
    De Backer, Steve
    Jeurissen, Ben
    Parizel, Paul M.
    Sijbers, Jan
    HUMAN BRAIN MAPPING, 2010, 31 (01) : 98 - 114
  • [12] Voxel-based approach to generate entire human metacarpal bone with microscopic architecture for finite element analysis
    Tang, C. Y.
    Tsui, C. P.
    Tang, Y. M.
    Wei, L.
    Wong, C. T.
    Lam, K. W.
    Ip, W. Y.
    Lu, W. W. J.
    Pang, M. Y. C.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (02) : 1469 - 1484
  • [13] Effect of size and location of simulated lytic lesions on the structural properties of human vertebral bodies, a micro-finite element study
    Costa, M. C.
    Campello, L. B. Bresani
    Ryan, M.
    Rochester, J.
    Viceconti, M.
    Dall'Ara, E.
    BONE REPORTS, 2020, 12
  • [14] An Efficient LiDAR SLAM With Angle-Based Feature Extraction and Voxel-Based Fixed-Lag Smoothing
    Li, Nuo
    Yao, Yiqing
    Xu, Xiaosu
    Peng, Yiyang
    Wang, Zijian
    Wei, Hongyu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [15] A study of diffusion tensor imaging by tissue-specific, smoothing-compensated voxel-based analysis
    Lee, Jee Eun
    Chung, Moo K.
    Lazar, Mariana
    DuBray, Molly B.
    Kim, Jinsuh
    Bigler, Erin D.
    Lainhart, Janet E.
    Alexander, Andrew L.
    NEUROIMAGE, 2009, 44 (03) : 870 - 883
  • [16] What You See Is Not What You Get: On the Accuracy of Voxel-Based Dosimetry in Molecular Radiotherapy
    Tran-Gia, Johannes
    Salas-Ramirez, Maikol
    Lassmann, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (08) : 1178 - 1186
  • [17] Optimization of the failure criterion in micro-Finite Element models of the mouse tibia for the non-invasive prediction of its failure load in preclinical applications
    Oliviero, S.
    Owen, R.
    Reilly, G. C.
    Bellantuono, I
    Dall'Ara, E.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113
  • [18] Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis
    Ovesy, Marzieh
    Indermaur, Michael
    Zysset, Philippe K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 98 : 301 - 310
  • [19] A dual element based geometric element transformation method for all-hexahedral mesh smoothing
    Vartziotis, Dimitris
    Wipper, Joachim
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2011, 200 (9-12) : 1186 - 1203
  • [20] Mechanical analysis of three-dimensional braided composites by using realistic voxel-based model with local mesh refinement
    Fang, Guodong
    Chen, Chenghua
    Meng, Songhe
    Liang, Jun
    JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (04) : 475 - 487