Glucose sensing and hybrid instrumentation based on printed organic electrochemical transistors

被引:13
作者
Nair, Rakesh Rajendran [1 ]
机构
[1] Saralon GmbH, Chemnitz, Germany
来源
FLEXIBLE AND PRINTED ELECTRONICS | 2020年 / 5卷 / 01期
关键词
printed transistor; screen printing; hybrid circuit; glucose; organic electrochemical transistor (OECT); SENSORS;
D O I
10.1088/2058-8585/ab63a0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This report presents the design and fabrication of a fully open-air printed organic polymer biosensor for detecting hypo/hyperglycaemia among humans with a fully integrated inorganic measurement and notification circuitry fabricated on a single flexible plastic substrate. The sensor is based on the electrochemical doping and de-doping of the degenerately doped organic semiconductor Poly(3,4-ethylenedioxythiophene) poly(styrene sulphonate) (PEDOT:PSS). The printed sensor reported herein, demonstrated sensitivity between 0.001 and 10 mM glucose concentrations utilizing a PEDOT: PSS gate, hence allowing for saliva-based, non-invasive glucose measurements. Transimpedance amplification and data processing circuitry for a prototype measurement and notification system was developed using three inexpensive chips: On Semiconductor's CAT102 precision regulator, Texas Instruments' LM358DR op-amp and Microchip's-ATMEGA328PB-AUR, all integrated on the same polyethylene terephthalate substrate using screen-printed Ag interconnects and vertically conducting anisotropic glue to demonstrate the system's practicability as a cheap, self-reliant, battery powered bio-sensing module. To demonstrate the efficacy of the system 'as is', no redox mediators to amplify the biosensor response were employed.
引用
收藏
页数:7
相关论文
共 18 条
[11]   Highly selective and sensitive glucose sensors based on organic electrochemical transistors using TiO2 nanotube arrays-based gate electrodes [J].
Liao, Jianjun ;
Lin, Shiwei ;
Yang, Yue ;
Liu, Kai ;
Du, Wencai .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 :457-463
[12]   Glucose sensor based on organic thin film transistor using glucose oxidase and conducting polymer [J].
Liu, J. ;
Agarwal, M. ;
Varahramyan, K. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :195-199
[13]   Screen-printed organic electrochemical transistors for metabolite sensing [J].
Scheiblin, Gaetan ;
Aliane, Abdelkader ;
Strakosas, Xenofon ;
Curto, Vincenzo F. ;
Coppard, Romain ;
Marchand, Gilles ;
Owens, Roisin M. ;
Mailley, Pascal ;
Malliaras, George G. .
MRS COMMUNICATIONS, 2015, 5 (03) :507-511
[14]   CHEMICALLY RESPONSIVE MICROELECTROCHEMICAL DEVICES BASED ON PLATINIZED POLY(3-METHYLTHIOPHENE) - VARIATION IN CONDUCTIVITY WITH VARIATION IN HYDROGEN, OXYGEN, OR PH IN AQUEOUS-SOLUTION [J].
THACKERAY, JW ;
WRIGHTON, MS .
JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (25) :6674-6679
[15]   Noninvasively measuring blood glucose using saliva [J].
Yamaguchi, M ;
Mitsumori, M ;
Kano, Y .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (03) :59-63
[16]   Electrochemical transistors with ionic liquids for enzymatic sensing [J].
Yang, Sang Yoon ;
Cicoira, Fabio ;
Byrne, Robert ;
Benito-Lopez, Fernando ;
Diamond, Dermot ;
Owens, Roisin M. ;
Malliaras, George G. .
CHEMICAL COMMUNICATIONS, 2010, 46 (42) :7972-7974
[17]  
Zhu Z.T., 2004, CHEM COMMUN, V13, P1556, DOI DOI 10.1039/b403327m
[18]   A simple poly(3,4-ethylene dioxythiophene)/poly(styrene sulfonic acid) transistor for glucose sensing at neutral pH [J].
Zhu, ZT ;
Mabeck, JT ;
Zhu, CC ;
Cady, NC ;
Batt, CA ;
Malliaras, GG .
CHEMICAL COMMUNICATIONS, 2004, (13) :1556-1557