Amperometric pH Sensor Based on Graphene-Polyaniline Composite

被引:32
|
作者
Sha, Rinky [1 ]
Komori, Kikuo [2 ,3 ]
Badhulika, Sushmee [1 ]
机构
[1] Indian Inst Technol Hyderabad, Dept Elect Engn, Hyderabad 502285, Andhra Pradesh, India
[2] Univ Tokyo, Dept Chem Syst Engn, Tokyo 1138656, Japan
[3] Univ Tokyo, Inst Ind Sci, Tokyo 1538505, Japan
关键词
Graphene; polyaniline; nano composite; electrodeposition; pH sensor; CARBON NANOTUBE; NANOCOMPOSITE; TRANSISTORS; SUPERCAPACITOR; ELECTRODE; NANOWIRE; FILM;
D O I
10.1109/JSEN.2017.2720634
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Here, we report a grapheme-polyaniline (Gr-PANi) composite modified glassy carbon electrode (GCE) as an amperometric pH sensor. Gr-PANi composite was synthesized by electrodeposition of PANi on the surface of Gr modified GCE using the cyclic voltammetry technique. XRD and Raman analysis confirmed high crystallinity of Gr-PANi composite. FESEM analysis revealed that Gr flakes are surrounded by PANi film because of the heterogeneous nucleation and growth of PANi during electro-polymerization. In acidic region, current of the composite-based pH sensor increased with decreasing pH values of the solution, whereas in alkaline region, current increased with the increasing pH values of the solution. The as-fabricated pH sensor exhibits shorter response time with an excellent sensitivity of -50.14 mu A pH(-1) cm(-2) in the range of pH 1-5 and 139.2 mu A pH(-1) cm(-2) in the range of pH 7-11. The composite-based sensor showed enhanced sensitivity compared with pure Gr-based pH sensor because unlike pristine Gr-based pH sensor, it utilizes both charge-storage mechanisms in EDLCs and pseudo-capacitors, thereby resulting in excellent synergy between Gr and PANi. Reproducibility of the pH sensor was also examined between three different electrodes in the solution of pH 5. Insignificant variation in the current response suggested excellent reproducibility of pH sensor. To the best of our knowledge, no other studies have been reported on the Gr-PANi composite-based pH sensor over wide pH range. This Gr-PANi-based pH sensor offers a simple, low-cost, promising, real-time amperometric pH sensor in chemistry, clinical diagnostics, bio-sensing, and environmental monitoring applications.
引用
收藏
页码:5038 / 5043
页数:6
相关论文
共 50 条
  • [31] Synergistic effects of graphene-polyaniline counter electrode in dye-sensitised solar cells
    Loryuenyong, Vorrada
    Yaotrakool, Sajjarinee
    Prathumted, Pratya
    Lertsiri, Julaluck
    Buasri, Achanai
    MICRO & NANO LETTERS, 2016, 11 (02): : 77 - 80
  • [32] Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
    Chinnathambi, Selvaraj
    Euverink, Gert-Jan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [33] Supercapacitors Based on Flexible Graphene/Polyaniline Nanofiber Composite Films
    Wu, Qiong
    Xu, Yuxi
    Yao, Zhiyi
    Liu, Anran
    Shi, Gaoquan
    ACS NANO, 2010, 4 (04) : 1963 - 1970
  • [35] Copper nanoparticles/polyaniline/molybdenum disulfide composite as a nonenzymatic electrochemical glucose sensor
    Sharma, Krishna Prasad
    Shin, Miyeon
    Kim, Kyong
    Woo, Kyungmin
    Awasthi, Ganesh Prasad
    Yu, Changho
    HELIYON, 2023, 9 (12)
  • [36] Polyaniline/Graphene Composite as Supercapacitor Electrode
    Zheng, Ming-Sen
    Wei, Zhi-Kai
    Dong, Quan-Feng
    NEW MATERIALS AND PROCESSES, PTS 1-3, 2012, 476-478 : 1446 - 1449
  • [37] Preparation of an Amide Group-Connected Graphene-Polyaniline Nanofiber Hybrid and Its Application in Supercapacitors
    Liu Jianhua
    An Junwei
    Zhou Yecheng
    Ma Yuxiao
    Li Mengliu
    Yu Mei
    Li Songmei
    ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (06) : 2870 - 2876
  • [38] Graphene-Polyaniline Nanocomposite Treated with Microwave as a New Supercapacitor Electrode and its Structural, Electrochemical Properties
    Kandasamy, Senthil Kumar
    Kandasamy, Kannan
    JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2019, 22 (03) : 125 - 131
  • [39] Amperometric thyroxine sensor using a nanocomposite based on graphene modified with gold nanoparticles carrying a thiolated β-cyclodextrin
    Munoz, Jose
    Riba-Moliner, Marta
    Brennan, Lorcan J.
    Gun'ko, Yurii K.
    Cespedes, Francisco
    Gonzalez-Campo, Arantzazu
    Baeza, Mireia
    MICROCHIMICA ACTA, 2016, 183 (05) : 1579 - 1589
  • [40] Electrosynthesis of a composite based on graphene oxide nanosheets and polyaniline with hexachloroiridate anion
    Abalyaeva, V. V.
    Baskakov, S. A.
    Dremova, N. N.
    Efimov, O. N.
    RUSSIAN CHEMICAL BULLETIN, 2014, 63 (03) : 627 - 634