Amperometric pH Sensor Based on Graphene-Polyaniline Composite

被引:32
|
作者
Sha, Rinky [1 ]
Komori, Kikuo [2 ,3 ]
Badhulika, Sushmee [1 ]
机构
[1] Indian Inst Technol Hyderabad, Dept Elect Engn, Hyderabad 502285, Andhra Pradesh, India
[2] Univ Tokyo, Dept Chem Syst Engn, Tokyo 1138656, Japan
[3] Univ Tokyo, Inst Ind Sci, Tokyo 1538505, Japan
关键词
Graphene; polyaniline; nano composite; electrodeposition; pH sensor; CARBON NANOTUBE; NANOCOMPOSITE; TRANSISTORS; SUPERCAPACITOR; ELECTRODE; NANOWIRE; FILM;
D O I
10.1109/JSEN.2017.2720634
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Here, we report a grapheme-polyaniline (Gr-PANi) composite modified glassy carbon electrode (GCE) as an amperometric pH sensor. Gr-PANi composite was synthesized by electrodeposition of PANi on the surface of Gr modified GCE using the cyclic voltammetry technique. XRD and Raman analysis confirmed high crystallinity of Gr-PANi composite. FESEM analysis revealed that Gr flakes are surrounded by PANi film because of the heterogeneous nucleation and growth of PANi during electro-polymerization. In acidic region, current of the composite-based pH sensor increased with decreasing pH values of the solution, whereas in alkaline region, current increased with the increasing pH values of the solution. The as-fabricated pH sensor exhibits shorter response time with an excellent sensitivity of -50.14 mu A pH(-1) cm(-2) in the range of pH 1-5 and 139.2 mu A pH(-1) cm(-2) in the range of pH 7-11. The composite-based sensor showed enhanced sensitivity compared with pure Gr-based pH sensor because unlike pristine Gr-based pH sensor, it utilizes both charge-storage mechanisms in EDLCs and pseudo-capacitors, thereby resulting in excellent synergy between Gr and PANi. Reproducibility of the pH sensor was also examined between three different electrodes in the solution of pH 5. Insignificant variation in the current response suggested excellent reproducibility of pH sensor. To the best of our knowledge, no other studies have been reported on the Gr-PANi composite-based pH sensor over wide pH range. This Gr-PANi-based pH sensor offers a simple, low-cost, promising, real-time amperometric pH sensor in chemistry, clinical diagnostics, bio-sensing, and environmental monitoring applications.
引用
收藏
页码:5038 / 5043
页数:6
相关论文
共 50 条
  • [21] Fabrication of Free-Standing, Electrochemically Active, and Biocompatible Graphene Oxide-Polyaniline and Graphene-Polyaniline Hybrid Papers
    Yan, Xingbin
    Chen, Jiangtao
    Yang, Jie
    Xue, Qunji
    Miele, Philippe
    ACS APPLIED MATERIALS & INTERFACES, 2010, 2 (09) : 2521 - 2529
  • [22] Recent Advances in Electrochemical Performances of Graphene Composite (Graphene-Polyaniline/Polypyrrole/Activated Carbon/Carbon Nanotube) Electrode Materials for Supercapacitor: A Review
    Senthil Kumar Kandasamy
    Kannan Kandasamy
    Journal of Inorganic and Organometallic Polymers and Materials, 2018, 28 : 559 - 584
  • [23] Recent Advances in Electrochemical Performances of Graphene Composite (Graphene-Polyaniline/Polypyrrole/Activated Carbon/Carbon Nanotube) Electrode Materials for Supercapacitor: A Review
    Kandasamy, Senthil Kumar
    Kandasamy, Kannan
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2018, 28 (03) : 559 - 584
  • [24] An Acetylcholinesterase Biosensor Based on Graphene/Polyaniline Composite Film for Detection of Pesticides
    Li, Yanping
    Zhang, Yuyu
    Han, Gaoyi
    Xiao, Yaoming
    Li, Miaoyu
    Zhou, Wen
    CHINESE JOURNAL OF CHEMISTRY, 2016, 34 (01) : 82 - 88
  • [25] Polyaniline/Graphene oxide composite as an Ultra-Sensitive humidity sensor
    Chethan, B.
    Prasad, V.
    Mathew, Seena
    Jan, Husna
    INORGANIC CHEMISTRY COMMUNICATIONS, 2024, 166
  • [26] Three-dimensional hollow balls of graphene-polyaniline hybrids for supercapacitor applications
    Nguyen Bao Trung
    Tran Van Tam
    Kim, Hye Ryeon
    Hur, Seung Hyun
    Kim, Eui Jung
    Choi, Won Mook
    CHEMICAL ENGINEERING JOURNAL, 2014, 255 : 89 - 96
  • [27] Graphene-polyaniline modified electrochemical droplet-based microfluidic sensor for high-throughput determination of 4-aminophenol
    Rattanarat, Poomrat
    Suea-Ngam, Akkapol
    Ruecha, Nipapan
    Siangproh, Weena
    Henry, Charles S.
    Monpichar, Srisa-Art
    Chailapakul, Orawon
    ANALYTICA CHIMICA ACTA, 2016, 925 : 51 - 60
  • [28] Functionalized graphene-polyaniline nanocomposite as electrode material for asymmetric supercapacitors
    Bao, Changyuan
    He, Qingqing
    Han, Jiajun
    Cheng, Jinning
    Zhang, Ruitao
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (09) : 2917 - 2928
  • [29] Development of glucose biosensors based on nanostructured graphene-conducting polyaniline composite
    Feng, Xue
    Cheng, Huijun
    Pan, Yiwen
    Zheng, Hao
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 411 - 417
  • [30] Supercapacitor electrode based on three-dimensional graphene-polyaniline hybrid
    Dong, Xiaochen
    Wang, Jingxia
    Wang, Jing
    Chan-Park, Mary B.
    Li, Xingao
    Wang, Lianhui
    Huang, Wei
    Chen, Peng
    MATERIALS CHEMISTRY AND PHYSICS, 2012, 134 (2-3) : 576 - 580