Pre-analytical stability of sorbitol dehydrogenase in equine heparinized plasma

被引:2
|
作者
Fouch, N. [1 ,2 ]
Oesch, S. [1 ,2 ]
Gerber, V. [1 ,2 ]
Richter, H. [3 ]
Howard, J. [4 ]
Peters, L. M. [4 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Zurich, Vetsuisse Fac, Dept Clin Diagnost & Serv, Diagnost Imaging Res Unit, Zurich, Switzerland
[4] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Clin Diagnost Lab, Bern, Switzerland
关键词
Biochemical analysis; Hepatic enzymes; Horse; Iditol dehydrogenase; Storage temperature; PROGNOSTIC EVALUATION; SERUM; DIAGNOSIS; SYSTEM; HORSE;
D O I
10.1016/j.tvjl.2021.105706
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Sorbitol dehydrogenase (SDH) activity is one of the most sensitive and specific markers for hepatocellular injury in horses, but its reported lability makes it impractical for use in many clinical settings. To date, stability of SDH in equine samples has only been evaluated in a limited number of studies in serum samples of horses with activities within reference intervals. The objective of the study was to determine pre-analytical stability of equine SDH activity in heparinized plasma stored at different temperatures for up to 72 h. Twenty client-owned horses admitted to a veterinary teaching hospital for any reason were included in the study. Blood samples collected in lithium-heparin tubes were immediately centrifuged and SDH activity was analyzed within 1 h of collection (T0). Aliquots of plasma were stored at room temperature, 4 degrees C and -20 degrees C and SDH activity was re-analyzed after 4 h (T4), 24 h (T24) and 72 h (T72). A significant difference from values measured at T0 was found for samples stored at room temperature (P = 0.022) and -20 degrees C (P < 0.001), but not at 4 degrees C. The activity of SDH was within +/- 20% of that measured at T0 for all samples under all temperature conditions stored for 4 h, and for all samples stored at 4 degrees C for 24 h. Bland-Altman plots revealed narrow limits of agreement at T4 for all storage temperatures and at T24 for samples stored at 4 degrees C. The mean absolute percentage error and 95th percentile of the absolute percentage error were lower for samples stored at 4 degrees C than those stored at room temperature or -20 degrees C. The activity of SDH has adequate stability for 4 h regardless of storage temperature and 24 h if stored at 4 degrees C across a wide range of values. Knowledge of the pre-analytical stability of SDH may permit its broader use in assessing hepatic disorders in horses.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Pre-analytical Errors in Glucose Estimation Results in Query on Diabetic Management
    Loganathan, Preethi
    Gasper, Sampath Kumar
    Afel, Fathima Kader
    Kandaswamy, Selvakumar
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2020, 35 (01) : 32 - 42
  • [42] Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry
    Bolliger, Daniel
    Seeberger, Manfred D.
    Tanaka, Kenichi A.
    Dell-Kuster, Salome
    Gregor, Michael
    Zenklusen, Urs
    Grapow, Martin
    Tsakiris, Dimitrios A.
    Filipovic, Miodrag
    PLATELETS, 2009, 20 (07) : 458 - 465
  • [43] The pre-analytical processing of blood samples for detecting biomarkers on protein microarrays
    Rosskopf, Sandra
    Gyurjan, Istvan
    Luna-Coronell, Johana A.
    Vierlinger, Klemens
    Singer, Christian F.
    Rappaport, Christine
    Pecha, Nina
    Weinhaeusel, Andreas
    JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 418 : 39 - 51
  • [44] An Overview of Pre-Analytical Factors Impacting Metabolomics Analyses of Blood Samples
    Thachil, Amy
    Wang, Li
    Mandal, Rupasri
    Wishart, David
    Blydt-Hansen, Tom
    METABOLITES, 2024, 14 (09)
  • [45] Differences in metabolite profiles caused by pre-analytical blood processing procedures
    Nishiumi, Shin
    Suzuki, Makoto
    Kobayashi, Takashi
    Yoshida, Masaru
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2018, 125 (05) : 613 - 618
  • [46] Effects of pre-analytical processes on blood samples used in metabolomics studies
    Peiyuan Yin
    Rainer Lehmann
    Guowang Xu
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4879 - 4892
  • [47] Effects of pre-analytical processes on blood samples used in metabolomics studies
    Yin, Peiyuan
    Lehmann, Rainer
    Xu, Guowang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (17) : 4879 - 4892
  • [48] Effect of pre-analytical variables on Raman and FTIR spectral content of lymphocytes
    Monaghan, Jade F.
    Cullen, Daniel
    Wynne, Claire
    Lyng, Fiona M.
    Meade, Aidan D.
    ANALYST, 2023, 148 (21) : 5422 - 5434
  • [49] Pre-analytical operating procedures for serum Low Molecular Weight protein profiling
    Di Girolamo, Francesco
    Alessandroni, Jhessica
    Somma, Paolo
    Guadagni, Fiorella
    JOURNAL OF PROTEOMICS, 2010, 73 (03) : 667 - 677
  • [50] Quantitative protein mass-spectrometry requires a standardized pre-analytical phase
    Smit, Nico P. M.
    Romijn, Fred P. H. T. M.
    van Ham, Vanessa J. J.
    Reijnders, Esther
    Cobbaert, Christa M.
    Ruhaak, L. Renee
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (01) : 55 - 66