Pre-analytical stability of sorbitol dehydrogenase in equine heparinized plasma

被引:2
|
作者
Fouch, N. [1 ,2 ]
Oesch, S. [1 ,2 ]
Gerber, V. [1 ,2 ]
Richter, H. [3 ]
Howard, J. [4 ]
Peters, L. M. [4 ]
机构
[1] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Swiss Inst Equine Med, Bern, Switzerland
[2] Agroscope, Bern, Switzerland
[3] Univ Zurich, Vetsuisse Fac, Dept Clin Diagnost & Serv, Diagnost Imaging Res Unit, Zurich, Switzerland
[4] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Clin Diagnost Lab, Bern, Switzerland
关键词
Biochemical analysis; Hepatic enzymes; Horse; Iditol dehydrogenase; Storage temperature; PROGNOSTIC EVALUATION; SERUM; DIAGNOSIS; SYSTEM; HORSE;
D O I
10.1016/j.tvjl.2021.105706
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Sorbitol dehydrogenase (SDH) activity is one of the most sensitive and specific markers for hepatocellular injury in horses, but its reported lability makes it impractical for use in many clinical settings. To date, stability of SDH in equine samples has only been evaluated in a limited number of studies in serum samples of horses with activities within reference intervals. The objective of the study was to determine pre-analytical stability of equine SDH activity in heparinized plasma stored at different temperatures for up to 72 h. Twenty client-owned horses admitted to a veterinary teaching hospital for any reason were included in the study. Blood samples collected in lithium-heparin tubes were immediately centrifuged and SDH activity was analyzed within 1 h of collection (T0). Aliquots of plasma were stored at room temperature, 4 degrees C and -20 degrees C and SDH activity was re-analyzed after 4 h (T4), 24 h (T24) and 72 h (T72). A significant difference from values measured at T0 was found for samples stored at room temperature (P = 0.022) and -20 degrees C (P < 0.001), but not at 4 degrees C. The activity of SDH was within +/- 20% of that measured at T0 for all samples under all temperature conditions stored for 4 h, and for all samples stored at 4 degrees C for 24 h. Bland-Altman plots revealed narrow limits of agreement at T4 for all storage temperatures and at T24 for samples stored at 4 degrees C. The mean absolute percentage error and 95th percentile of the absolute percentage error were lower for samples stored at 4 degrees C than those stored at room temperature or -20 degrees C. The activity of SDH has adequate stability for 4 h regardless of storage temperature and 24 h if stored at 4 degrees C across a wide range of values. Knowledge of the pre-analytical stability of SDH may permit its broader use in assessing hepatic disorders in horses.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Clinical Practice Guidelines for Pre-Analytical Procedures of Plasma Epidermal Growth Factor Receptor Variant Testing
    Shin, Saeam
    Woo, Hye In
    Kim, Jong-Won
    Kim, Yoonjung
    Lee, Kyung-A
    ANNALS OF LABORATORY MEDICINE, 2022, 42 (02) : 141 - +
  • [32] Pre-analytical considerations in biomarker research: focus on cardiovascular disease
    Revuelta-Lopez, Elena
    Barallat, Jaume
    Cserkoova, Adriana
    Galvez-Monton, Carolina
    Jaffe, Allan S.
    Januzzi, James L.
    Bayes-Genis, Antoni
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (11) : 1747 - 1760
  • [33] Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks
    Bernini, Patrizia
    Bertini, Ivano
    Luchinat, Claudio
    Nincheri, Paola
    Staderini, Samuele
    Turano, Paola
    JOURNAL OF BIOMOLECULAR NMR, 2011, 49 (3-4) : 231 - 243
  • [34] Quantification of mitochondrial DNA copy number: Pre-analytical factors
    Andreu, Antonio L.
    Martinez, Ramiro
    Marti, Ramon
    Garcia-Arumi, Elena
    MITOCHONDRION, 2009, 9 (04) : 242 - 246
  • [35] Metrics for identifying errors related to pre-analytical sample handling
    Kittanakom, Saranya
    Kavsak, Peter A.
    CLINICAL BIOCHEMISTRY, 2014, 47 (12) : 989 - 990
  • [36] The Effect of Pre-Analytical Conditions on Blood Metabolomics in Epidemiological Studies
    Ferreira, Diana L. Santos
    Maple, Hannah J.
    Goodwin, Matt
    Brand, Judith S.
    Yip, Vikki
    Min, Josine L.
    Groom, Alix
    Lawlor, Debbie A.
    Ring, Susan
    METABOLITES, 2019, 9 (04):
  • [37] Bone turnover markers are differentially affected by pre-analytical handling
    Christensen, G. L.
    Halgreen, J. R.
    Milenkovski, M.
    Kose, A.
    Quardon, N.
    Jorgensen, N. R.
    OSTEOPOROSIS INTERNATIONAL, 2019, 30 (05) : 1137 - 1141
  • [38] Stability of lactate dehydrogenase in plasma at different temperatures: post-analytical storage
    Lopez, Marta Gomez
    Roca, Neila Rodriguez
    Velasco, Manuela Simon
    Martin, Maria Jose Alcaide
    Soto, Antonio Buno
    Rioja, Ruben Gomez
    ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2020, 1 (04):
  • [39] Pre-analytical stability of haematinics, lactate dehydrogenase and phosphate in whole blood at room temperature up to 24 h, and refrigerated serum stability of lactate dehydrogenase, folate and vitamin B12 up to 72 h using the CRESS checklist
    Williams, Robert
    Jankute, Monika
    Ifrahim, Rizwan
    Cordle, Jane
    Hepburn, Sophie
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, : 734 - 746
  • [40] Identification of Clinical Biomarkers for Pre-Analytical Quality Control of Blood Samples
    Kang, Hyun Ju
    Jeon, Soon Young
    Park, Jae-Sun
    Yun, Ji Young
    Kil, Han Na
    Hong, Won Kyung
    Lee, Mee-Hee
    Kim, Jun-Woo
    Jeon, Jae-Pil
    Han, Bok Ghee
    BIOPRESERVATION AND BIOBANKING, 2013, 11 (02) : 94 - 100