Quantitative image based apoptotic index measurement using multispectral imaging flow cytometry: a comparison with standard photometric methods

被引:75
作者
Henery, Shannon [1 ]
George, Thaddeus [1 ]
Hall, Brian [1 ]
Basiji, David [1 ]
Ortyn, William [1 ]
Morrissey, Philip [1 ]
机构
[1] Amnis Corp, Seattle, WA 98121 USA
关键词
chromatin condensation; nuclear fragmentation; DNA fragmentation; quantitative apoptotic index; nuclear condensation; Annexin V; caspase substrate; TUNEL;
D O I
10.1007/s10495-008-0227-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Morphological characterization by microscopy remains the gold standard for accurately identifying apoptotic cells using characteristics such as nuclear condensation, nuclear fragmentation, and membrane blebbing. However, quantitative measurement of apoptotic morphology using microscopy can be time consuming and can lack objectivity and reproducibility, making it difficult to identify subtle changes in large populations. Thus the apoptotic index of a sample is commonly measured by flow cytometry using a variety of fluorescence intensity based (photometric) assays which target hallmarks of apoptosis with secondary markers such as the TUNEL (Terminal Deoxynucleotide Transferase dUTP Nick End Labeling) assay for detection of DNA fragmentation, the Annexin V assay for surface phosphatidylserine (PS) exposure, and fluorogenic caspase substrates to detect caspase activation. Here a novel method is presented for accurate quantitation of apoptosis based on nuclear condensation, nuclear fragmentation, and membrane blebbing using automated image analysis on large numbers of images collected in flow by the ImageStream multispectral imaging cytometer. Additionally the measurement of nuclear fragmentation correlates with the secondary methods of detection of apoptosis over time, indicating that it is also an early marker for apoptosis. False-positive and false-negative events associated with each photometric flow cytometry based method are quantitated and can be automatically removed/included where appropriate. Acquisition of multi-spectral imagery on large numbers of cells couples the quantitative advantage of flow cytometry with the accuracy of morphology-based algorithms allowing more complete and robust analysis of apoptosis.
引用
收藏
页码:1054 / 1063
页数:10
相关论文
共 29 条
[1]  
Bedner E, 1998, CYTOMETRY, V33, P47, DOI 10.1002/(SICI)1097-0320(19980901)33:1&lt
[2]  
47::AID-CYTO6&gt
[3]  
3.0.CO
[4]  
2-8
[5]  
Bedner E, 1999, CYTOMETRY, V35, P181, DOI 10.1002/(SICI)1097-0320(19990301)35:3<181::AID-CYTO1>3.0.CO
[6]  
2-5
[7]   Quantitative analysis of protein co-localization on B cells opsonized with rituximab and complement using the ImageStream multispectral imaging flow cytometer [J].
Beum, Paul V. ;
Lindorfer, Margaret A. ;
Hall, Brian E. ;
George, Thaddeus C. ;
Frost, Keith ;
Morrissey, Philip J. ;
Taylor, Ronald P. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 317 (1-2) :90-99
[8]   Molecular mechanism of staurosporine-induced apoptosis in osteoblasts [J].
Chae, HJ ;
Kang, JS ;
Byun, JO ;
Han, KS ;
Kim, DU ;
Oh, SM ;
Kim, HM ;
Chae, SW ;
Kim, HR .
PHARMACOLOGICAL RESEARCH, 2000, 42 (04) :373-381
[9]   Identification of caspase-independent apoptosis in epithelial and cancer cells [J].
Cummings, BS ;
Kinsey, GR ;
Bolchoz, LJC ;
Schnellmann, RG .
JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2004, 310 (01) :126-134
[10]   Flow cytometry in analysis of cell cycle and apoptosis [J].
Darzynkiewicz, Z ;
Bedner, E ;
Smolewski, P .
SEMINARS IN HEMATOLOGY, 2001, 38 (02) :179-193