Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear

被引:28
|
作者
Compan, Vicente [1 ]
Aguilella-Arzo, Marcel [2 ]
Edrington, Timothy B. [3 ]
Weissman, Barry A. [3 ,4 ]
机构
[1] Univ Politecn Valencia, ETSII, Dept Termodinam Aplicada, Valencia, Spain
[2] Univ Jaume 1, Dept Fis, Castellon de La Plana, Spain
[3] Marshall B Ketchum Univ, Southern Calif Coll Optometry, 2575 Yorba Linda Blvd, Fullerton, CA 92831 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Stein Eye Inst, Dept Ophthalmol, Los Angeles, CA 90095 USA
关键词
scleral lenses; oxygen tension; oxygen consumption rate; tear film; corneal hypoxia; CONTACT-LENS; DIFFUSION-MODEL; CONSUMPTION; TENSION; EDEMA; TRANSMISSIBILITY; THICKNESS; TRANSPORT;
D O I
10.1097/OPX.0000000000000988
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The main goal of this current work is to use an updated calculation paradigm, and updated boundary conditions, to provide theoretical guidelines to assist the clinician whose goal is to improve his or her scleral gas permeable ( GP) contact lens wearing patients' anterior corneal oxygen supply. Methods. Our model uses a variable value of corneal oxygen consumption developed through Monod equations that disallows negative oxygen tensions within the stroma to predict oxygen tension at the anterior corneal surface of scleral GP contact lens wearing eyes, and to describe oxygen tension and flux profiles, for various boundary conditions, through the lens, tears, and cornea. We use several updated tissue and boundary parameters in our model. Tear exchange with GP scleral lenses is considered nonexistent in this model. Results. The majority of current scleral GP contact lenses should produce some levels of corneal hypoxia under open eye conditions. Only lenses producing the thinnest of tear vaults should result in anterior corneal surface oxygen tensions greater than a presumed critical oxygen tension of 100 mmHg. We also find that corneal oxygen tension and flux are each more sensitive to modification in tear vault than to changes in lens oxygen permeability, within the ranges of current clinical manipulation. Conclusions. Our study suggests that clinicians would be prudent to prescribe scleral GP lenses manufactured from higher oxygen permeability materials and especially to fit without excessive corneal clearance.
引用
收藏
页码:1339 / 1348
页数:10
相关论文
共 50 条
  • [1] Treatment of persistent corneal epithelial defect with extended wear of a fluid-ventilated gas-permeable scleral contact lens
    Rosenthal, P
    Cotter, JM
    Baum, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (01) : 33 - 41
  • [2] Corneal sensitivity in silicone hydrogel and rigid gas permeable contact lens wear
    Nosch, Daniela S.
    Kaser, Emanuele
    Christen, Alice
    Schinzel, Julia
    Joos, Roland E.
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (05):
  • [3] Corneal Response to Scleral Contact Lens Wear in Keratoconus
    Cagliari, Cristina
    Schor, Paulo
    Formentin, Luiz
    Lipener, Cesar
    dos Santos, Myrna Serapiao
    Oliveira, Helena
    de Carvalho Raulino Junior, Jose Ney
    de Freitas, Denise
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (08): : 322 - 327
  • [4] Changes in Corneal Parameters Associated with Scleral Lens Wear
    Schornack, Muriel
    Dodda, Samantha
    Nau, Cherie B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] Central Corneal Edema with Scleral-Lens Wear
    Kim, Young Hyun
    Tan, Bo
    Lin, Meng C.
    Radke, Clayton J.
    CURRENT EYE RESEARCH, 2018, 43 (11) : 1305 - 1315
  • [6] Modeling Corneal Metabolism and Oxygen Transport During Contact Lens Wear
    Chhabra, Mahendra
    Prausnitz, John M.
    Radke, Clayton J.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (05) : 454 - 466
  • [7] Prediction of Central Corneal Swelling with Scleral-Lens Wear
    Kim, Young Hyun
    Tan, Bo
    Lin, Meng C.
    Radke, Clayton J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Effect of Scleral Lens Oxygen Permeability on Corneal Physiology
    Dhallu, Sandeep K.
    Huarte, Sonia Trave
    Bilkhu, Paramdeep S.
    Boychev, Nikolay
    Wolffsohn, James S.
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 669 - 675
  • [9] Corneal oedema during reverse piggyback scleral lens wear
    Bliss, Vyasa H. H.
    Branjerdporn, Nathan
    Ooi, Peng Jia
    Teo, Li Mei
    Tu, Jervis
    Yeh, Justin
    Collins, Michael J. J.
    Vincent, Stephen J. J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1065 - 1069
  • [10] Corneal Health during Three Months of Scleral Lens Wear
    Tse, Vivien
    Zhou, Yixiu
    Truong, Tan
    Lin, Kristina
    Tan, Bo
    Lin, Meng C.
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 676 - 682