Toward Comprehensive Industrial Computed Tomography Image Quality Assessment: I. Phantom Design

被引:0
作者
Li, Xin [1 ]
Dentinger, Aaron [1 ]
Brault, Michelle [1 ]
Ross, William R. [1 ]
Osterlitz, Mark [1 ]
Fu, Lin [1 ]
Wu, Mingye [1 ]
Price, J. Scott [1 ]
De Man, Bruno [1 ]
Bueno, Clifford [1 ]
Fitzgerald, Paul [1 ]
机构
[1] GE Res, Niskayuna, NY 12309 USA
来源
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS | 2020年 / 3卷 / 03期
关键词
modular phantom; insert; image quality; inspection and measurement; industrial X-ray CT; imaging; X-ray;
D O I
10.1115/1.4046717
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
When comparing the performance of different industrial X-ray computed tomography (CT) systems, reconstruction algorithms, or scan protocols, it is important to assess how well the required inspection and measurement tasks can be performed. Furthermore, it can be very informative to quantify image quality (IQ) metrics that can provide insight into the IQ characteristics that lead to the resulting inspection or measurement task performance. Inspection and measurement task performance is determined by basic characteristics such as spatial resolution; feature contrast, size, and shape; random noise (noise due to statistical uncertainty in measurements); and image artifacts. In this report, we describe a modular phantom set that enables robustly quantifying these characteristics and also enables assessing the performance of the inspection or measurement tasks themselves. The phantom set includes two phantom bodies and several insert types that can be optionally installed in the bodies. Phantom body extensions can be optionally included to increase scatter. The phantom bodies combined with the available insert types can comprehensively evaluate all important IQ metrics and inspection or measurement tasks. The precisely-known phantom body geometry and insert location, geometry, and orientation supports automatic analysis of large, complex experiments of multiple variables. This phantom set, with the associated image analysis software, could potentially serve as a general evaluation method for non-destructive testing (NDT) CT.
引用
收藏
页数:7
相关论文
共 10 条
[1]  
ASTM International, 2013, E1695 STAND TEST MET
[2]  
Chen B., 2013, P VOLUME 8668 MEDICA
[3]  
GE, 2016, UN TOOL HIGH QUAL SC
[4]  
International Commission on Radiation Units and Measurements, 2012, J ICRU, V12, P1, DOI [10.1093/jicru/ndt007, 10.1093/jicru/ndv019]
[5]  
Miceli A., 2008, THESIS U BOLOGNA BOL
[6]  
Navnina B., 2015, C P DIG IND RAD COMP
[7]   A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT [J].
Peterzol, A. ;
Letang, J. M. ;
Babot, D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18) :4042-4054
[8]   Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms [J].
Richard, Samuel ;
Husarik, Daniela B. ;
Yadava, Girijesh ;
Murphy, Simon N. ;
Samei, Ehsan .
MEDICAL PHYSICS, 2012, 39 (07) :4115-4122
[9]  
Shedlock D., 2015, C P DIGITAL IND RADI
[10]   Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging [J].
Yu, Lifeng ;
Vrieze, Thomas J. ;
Leng, Shuai ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2015, 42 (05) :2261-2267