Optically coupled digital radiography: sources of inefficiency

被引:3
作者
Gagne, RM [1 ]
Quinn, PW [1 ]
Chen, LY [1 ]
Myers, KJ [1 ]
Doyle, R [1 ]
机构
[1] FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20857 USA
来源
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING | 2001年 / 4320卷
关键词
lens coupling; detective quantum efficiency; secondary quantum sink;
D O I
10.1117/12.430937
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Imaging systems comprised of a small detector which "looks" at a large area of a light emitting phosphor with a lens coupling system are commercially available. These imaging systems can be quite inefficient depending on the characteristics of the optical coupling. We have implemented an optically coupled imaging system in our laboratory for use as a test bed. The system includes a Kodak MR-2190 screen and a digital detector, i.e., a CCD camera. The laboratory system has provided the ability to investigate when a system of this configuration starts to develop a "secondary quantum sink" as a result of poor optical coupling. Experimental measurements have been made of the large area gray-scale transfer, resolution and noise properties of the imaging system at two different values of optical demagnification factor and three levels of x-ray exposure. The values of the detective quantum efficiency calculated from these measurements demonstrate a significant increase in absolute value and bandwidth when the demagnification decreases by a factor of approximately two.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 11 条
[1]   A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[2]  
CUNNINGHAM IA, 1994, P SOC PHOTO-OPT INS, V2163, P274, DOI 10.1117/12.174264
[3]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[4]  
*DHEW, DHEW PUBLICATION
[5]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .6. MTFS OF II-TV DIGITAL IMAGING-SYSTEMS [J].
FUJITA, H ;
DOI, K ;
GIGER, ML .
MEDICAL PHYSICS, 1985, 12 (06) :713-720
[6]   IMAGE-INFORMATION TRANSFER PROPERTIES OF X-RAY INTENSIFYING SCREENS IN THE ENERGY-RANGE FROM 17 TO 320 KEV [J].
GINZBURG, A ;
DICK, CE .
MEDICAL PHYSICS, 1993, 20 (04) :1013-1021
[7]   Potential image quality in scintillator CCD-based x-ray imaging systems for digital radiography and digital mammography [J].
Hejazi, S ;
Trauernicht, DP .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :440-449
[8]  
ICRU, 1996, 54 ICRU
[9]   METHODS TO CALCULATE THE LENS EFFICIENCY IN OPTICALLY COUPLED CCD X-RAY-IMAGING SYSTEMS [J].
LIU, H ;
KARELLAS, A ;
HARRIS, LJ ;
DORSI, CJ .
MEDICAL PHYSICS, 1994, 21 (07) :1193-1195
[10]  
MACOVSKI A, MED IMAGING SYSTEMS