The clinical and diagnostic impact of using standard criteria of adequacy assessment and diagnostic terminology on thyroid nodule fine needle aspiration

被引:27
作者
Jing, Xin [1 ]
Michael, Claire W. [1 ]
Pu, Robert T. [1 ]
机构
[1] Univ Michigan, Dept Pathol, Ann Arbor, MI 48109 USA
关键词
FNA; thyroid nodules; standard CAST;
D O I
10.1002/dc.20762
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The study was aimed to investigate the impact of using standard criteria for assessing specimen adequacy and diagnostic terminology (CAST) on fine-needle aspiration (FNA) diagnosis and clinical management of thyroid nodules. The study included similar numbers of FNAs performed in 2 year before (group A) and 1.5 year after (group B) implementing the standard CAST. In comparison to group A, group B showed a significantly lower rate of nondiagnostic specimens (RND) (16.1% vs. 21.6%, P < 0.01) and rate of descriptive diagnoses (RDD) (3.8% vs. 14.5%, P < 0.001) and greater non-neoplastic (70.0% vs. 64.1 %, P < 0.05) and follicular cell lesions (7.4% vs. 4.3%, P < 0.05) but a similar percentage of neoplastic diagnoses. The rate of surgical follow-up (RSF) was significantly higher in group B than in group A, overall (21.6% vs. 17.0%, P < 0.05), or in subgroups of non-neoplastic (12.6% vs. 5.4%, P < 0.01) and neoplastic categories (81.0% vs. 61.0%, P < 0.05). The rate of cytohistologic concordance was higher in group B although the difference was not statistically significant. We concluded that use of the standard CAST on FNA diagnosis of thyroid nodules significantly reduced RND and RDD, providing more consistent diagnoses among the pathologists as well as better and more uniform communication between the pathologists and the clinicians. Furthermore, the cytohistological concordance was slightly better after CAST implementation, indicating that the improvement of diagnostic consistency among pathologists did not sacrifice the diagnostic accuracy.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 23 条
[11]   Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodules [J].
Kelly, NP ;
Lim, JC ;
DeJong, S ;
Harmath, C ;
Ducliak, C ;
Wojcik, EM .
DIAGNOSTIC CYTOPATHOLOGY, 2006, 34 (03) :188-190
[12]  
MANDREKER SRS, 1995, ACTA CYTOL, V39, P898
[13]   LARGE CYSTIC SOLID THYROID-NODULES - A POTENTIAL FALSE-NEGATIVE FINE-NEEDLE ASPIRATION [J].
MEKO, JB ;
NORTON, JA .
SURGERY, 1995, 118 (06) :996-1004
[14]  
METHROTRA P, 2006, CYTOPATHOLOGY, V17, P137
[15]   Does Hurthle cell lesion/neoplasm predict malignancy more than follicular lesion/neoplasm on thyroid fine-needle aspiration? [J].
Pu, RT ;
Yang, J ;
Wasserman, PG ;
Bhuiya, T ;
Griffith, KA ;
Michael, CW .
DIAGNOSTIC CYTOPATHOLOGY, 2006, 34 (05) :330-334
[16]  
Rimm DL, 1997, CANCER CYTOPATHOL, V81, P51, DOI 10.1002/(SICI)1097-0142(19970225)81:1<51::AID-CNCR11>3.0.CO
[17]  
2-B
[18]  
SIDWAY MK, 1997, CANC CANC CYTOPATHOL, V81, P253
[19]  
Suen KC, 1996, DIAGN CYTOPATHOL, V15, P84, DOI 10.1002/(SICI)1097-0339(199607)15:1<84::AID-DC18>3.0.CO
[20]  
2-8