A phantom based study on the effect of subject positioning on morphometric X-ray absorptiometry using the Lunar EXPERT-XL

被引:4
|
作者
Thorpe, JA
Steel, SA
Langton, CM
机构
[1] Royal Hull Hosp, NHS Trust, Ctr Metab Bone Dis, Hull HU3 2RW, N Humberside, England
[2] Univ Hull, Hull Royal Infirm, Hull HU3 2RW, N Humberside, England
关键词
D O I
10.1259/bjr.71.851.10434910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric X-ray absorptiometry (MXA) relies on accurate measurement of vertical dimensions of vertebrae from a lateral perspective. Deviations resulting from scoliotic curvature or poor patient positioning produce distortions of visible vertebral dimensions and may lead to analysis error. This study utilized a phantom developed at this centre to assess the effect of vertebral malalignment on the accuracy of the MXA technique on the Lunar Expert-XL. Measured vertebral heights were found to be consistently underestimated by an average of 3.7%. Precision ranged from 0.79% for anterior height measurement to 1.03% for middle height measurement. Vertebral malalignment was investigated as the effect of rotation around the anteroposterior, lateral and superoinferior axes. Rotation around the lateral axis produced little discernible effect. However, superoinferior axial rotation showed a change of more than two standard deviations in the mid/posterior ratios of biconcave vertebrae at comparatively small angles of rotation. Anteroposterior axial rotation produced an increase in observed height at small angles of rotation, and a rapid decrease in vertebral height as rotation increased. The results suggest that whilst kyphosis or lordosis of up to at least 5.8 degrees has a minimal effect on MXA, scoliosis of 4.6 degrees or above produces a distinctive effect on the defining crush height ratios.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [31] THE ASSESSMENT OF FRACTURE-HEALING USING DUAL X-RAY ABSORPTIOMETRY - A FEASIBILITY STUDY USING PHANTOMS
    COOK, JE
    CUNNINGHAM, JL
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (01) : 119 - 136
  • [32] Primary Hyperparathyroidism: Assessment of the Effects of Parathyroidectomy Using Dual X-Ray Absorptiometry, Trabecular Bone Score, and Dual X-Ray Absorptiometry-Based Three-Dimensional Modeling
    Arboiro-Pinel, Rosa
    Mahillo-Fernandez, Ignacio
    Diaz-Curiel, Manuel
    ENDOCRINE PRACTICE, 2024, 30 (04) : 340 - 347
  • [33] Vertebral deformity prevalence determined by morphometric X-ray absorptiometry (MXA) in 4 population-based Finnish cohorts.
    Kroger, H
    ValveDietz, AK
    Huuskonen, J
    Jurvelin, J
    Honkanen, R
    Saarikoski, S
    Alhava, EM
    JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : F564 - F564
  • [34] Morphometric Vertebral Assessments via the Use of Dual X-ray Absorptiometry for the Evaluation of Radiographic Damage in Ankylosing Spondylitis: A Pilot Study
    Aubry-Rozier, Berengere
    Hans, Didier
    Krieg, Marc-Antoine
    Lamy, Olivier
    Dudler, Jean
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (01) : 190 - 194
  • [35] Assessment of fracture healing using dual x-ray absorptiometry. A feasibility study using phantoms
    Cook, J.E.
    Cunningham, J.L.
    Physics in Medicine and Biology, 1995, 40 (01):
  • [37] Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry
    Park, Chanwoo
    Song, Hankyeol
    Joung, Jinhun
    Kim, Yongkwon
    Kim, Kyu Bom
    Chung, Yong Hyun
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (10) : 2346 - 2352
  • [38] Scatter Correction for X-ray Imaging Using Primary Modulation: A Phantom Study for CBCT
    Zhu, Lei
    Bennett, Robert
    Fahrig, Rebecca
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1372 - +
  • [39] Investigating the level of agreement of two positioning protocols when using dual energy X-ray absorptiometry in the assessment of body composition
    Shiel, Flinn
    Persson, Carl
    Simas, Vini
    Furness, James
    Climstein, Mike
    Schram, Ben
    PEERJ, 2017, 5
  • [40] A phantom-based feasibility study for detection of gadolinium in bone in-vivo using X-ray fluorescence
    Lord, M. L.
    McNeill, F. E.
    Grafe, J. L.
    Noseworthy, M. D.
    Chettle, D. R.
    APPLIED RADIATION AND ISOTOPES, 2016, 112 : 103 - 109