A phantom based study on the effect of subject positioning on morphometric X-ray absorptiometry using the Lunar EXPERT-XL

被引:4
|
作者
Thorpe, JA
Steel, SA
Langton, CM
机构
[1] Royal Hull Hosp, NHS Trust, Ctr Metab Bone Dis, Hull HU3 2RW, N Humberside, England
[2] Univ Hull, Hull Royal Infirm, Hull HU3 2RW, N Humberside, England
关键词
D O I
10.1259/bjr.71.851.10434910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric X-ray absorptiometry (MXA) relies on accurate measurement of vertical dimensions of vertebrae from a lateral perspective. Deviations resulting from scoliotic curvature or poor patient positioning produce distortions of visible vertebral dimensions and may lead to analysis error. This study utilized a phantom developed at this centre to assess the effect of vertebral malalignment on the accuracy of the MXA technique on the Lunar Expert-XL. Measured vertebral heights were found to be consistently underestimated by an average of 3.7%. Precision ranged from 0.79% for anterior height measurement to 1.03% for middle height measurement. Vertebral malalignment was investigated as the effect of rotation around the anteroposterior, lateral and superoinferior axes. Rotation around the lateral axis produced little discernible effect. However, superoinferior axial rotation showed a change of more than two standard deviations in the mid/posterior ratios of biconcave vertebrae at comparatively small angles of rotation. Anteroposterior axial rotation produced an increase in observed height at small angles of rotation, and a rapid decrease in vertebral height as rotation increased. The results suggest that whilst kyphosis or lordosis of up to at least 5.8 degrees has a minimal effect on MXA, scoliosis of 4.6 degrees or above produces a distinctive effect on the defining crush height ratios.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [21] Errors in Patient Positioning for Bone Mineral Density Assessment by Dual X-Ray Absorptiometry: Effect of Technologist Retraining
    Promma, Sasivimol
    Sritara, Chanika
    Wipuchwongsakorn, Saowanee
    Chuamsaamarkkee, Krisanat
    Utamakul, Chirawat
    Chamroonrat, Wichana
    Kositwattanarerk, Arpakorn
    Anongpornjossakul, Yoch
    Thamnirat, Kanungnij
    Ongphiphadhanakul, Boonsong
    JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 252 - 259
  • [22] COMPARISON OF THREE KNEE POSITIONING PROTOCOLS FOR MEASURING KNEE MORPHOLOGY USING DUAL ENERGY X-RAY ABSORPTIOMETRY
    Walshaw, T. W.
    Beattie, K. A.
    Gregory, J. S.
    Barr, R. J.
    OSTEOARTHRITIS AND CARTILAGE, 2014, 22 : S302 - S303
  • [23] Segmental Musculoskeletal Examinations using Dual-Energy X-Ray Absorptiometry (DXA): Positioning and Analysis Considerations
    Hart, Nicolas H.
    Nimphius, Sophia
    Spiteri, Tania
    Cochrane, Jodie L.
    Newton, Robert U.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2015, 14 (03) : 620 - 626
  • [24] Morphometric X-ray absorptiometry: Reference data for vertebral dimensions in a population-based sample of young Danish men
    Wulff, R
    KochHolst, A
    Nielsen, TL
    Andersen, M
    Hagen, C
    Brixen, K
    ACTA RADIOLOGICA, 2004, 45 (08) : 859 - 865
  • [25] A cross-calibration study using a novel dual X-ray absorptiometry system for bone mineral density measurements with the European Spine Phantom
    Jiang, Yaojun
    Wu, Yan
    Zhang, Yonggao
    Yang, Xiaopeng
    Gao, Jianbo
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2119 - 2127
  • [26] Dose Absorption in Lumbar and Femoral Dual Energy X-ray Absorptiometry Examinations Using Three Different Scan Modalities: An Anthropomorphic Phantom Study
    Bandirali, Michele
    Lanza, Ezio
    Messina, Carmelo
    Sconfienza, Luca Maria
    Brambilla, Roberto
    Maurizio, Rozza
    Marchell, Daniele
    Piodi, Luca Petrucci
    Di Leo, Giovanni
    Ulivieri, Fabio Massimo
    Sardanelli, Francesco
    JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (03) : 279 - 282
  • [27] Comparative study on Lunar, Hologic, Norland dual energy X-ray bone densitometry with European Spine Phantom
    Bao, Ande
    Ma, Haibo
    Qin, Linlin
    Chen, Jinbiao
    Zhang, Yuanxun
    Li, Jin
    Sun, Jihui
    Yuan, Yi
    Ren, Sumei
    Sun, Shihua
    Yang, Liping
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 1999, 19 (05): : 352 - 356
  • [28] Bone strain index reproducibility and soft tissue thickness influence: a dual x-ray photon absorptiometry phantom study
    C. Messina
    L. P. Piodi
    L. Rinaudo
    I. Emili
    F. Porro
    C. Buonomenna
    L. M. Sconfienza
    L. Vergani
    F. M. Ulivieri
    European Radiology Experimental, 3
  • [29] Bone strain index reproducibility and soft tissue thickness influence: a dual x-ray photon absorptiometry phantom study
    Messina, C.
    Piodi, L. P.
    Rinaudo, L.
    Emili, I
    Porro, F.
    Buonomenna, C.
    Sconfienza, L. M.
    Vergani, L.
    Ulivieri, F. M.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) : 33
  • [30] Standardized positioning is essential for precise determination of body composition using dual-energy x-ray absorptiometry in dogs
    Raffan, Eleanor
    Holden, Shelley L.
    Cullingham, Fay
    Hackett, Rachel M.
    Rawlings, John M.
    German, Alexander J.
    JOURNAL OF NUTRITION, 2006, 136 (07) : 1976S - 1978S