A phantom based study on the effect of subject positioning on morphometric X-ray absorptiometry using the Lunar EXPERT-XL

被引:4
|
作者
Thorpe, JA
Steel, SA
Langton, CM
机构
[1] Royal Hull Hosp, NHS Trust, Ctr Metab Bone Dis, Hull HU3 2RW, N Humberside, England
[2] Univ Hull, Hull Royal Infirm, Hull HU3 2RW, N Humberside, England
关键词
D O I
10.1259/bjr.71.851.10434910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric X-ray absorptiometry (MXA) relies on accurate measurement of vertical dimensions of vertebrae from a lateral perspective. Deviations resulting from scoliotic curvature or poor patient positioning produce distortions of visible vertebral dimensions and may lead to analysis error. This study utilized a phantom developed at this centre to assess the effect of vertebral malalignment on the accuracy of the MXA technique on the Lunar Expert-XL. Measured vertebral heights were found to be consistently underestimated by an average of 3.7%. Precision ranged from 0.79% for anterior height measurement to 1.03% for middle height measurement. Vertebral malalignment was investigated as the effect of rotation around the anteroposterior, lateral and superoinferior axes. Rotation around the lateral axis produced little discernible effect. However, superoinferior axial rotation showed a change of more than two standard deviations in the mid/posterior ratios of biconcave vertebrae at comparatively small angles of rotation. Anteroposterior axial rotation produced an increase in observed height at small angles of rotation, and a rapid decrease in vertebral height as rotation increased. The results suggest that whilst kyphosis or lordosis of up to at least 5.8 degrees has a minimal effect on MXA, scoliosis of 4.6 degrees or above produces a distinctive effect on the defining crush height ratios.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 50 条
  • [11] Identification of vertebral deformities in the Polish population by morphometric X-ray absorptiometry - results of the EPOLOS study
    Skowronska-Jozwiak, Elzbieta
    Pludowski, Pawel
    Karczmarewicz, Elzbieta
    Lorenc, Roman
    Lewinski, Andrzej
    ENDOKRYNOLOGIA POLSKA, 2009, 60 (02) : 68 - 75
  • [12] Identification of vertebral deformities in women: Comparison of radiological assessment and quantitative morphometry using morphometric radiography and morphometric X-ray absorptiometry
    Ferrar, L
    Jiang, G
    Barrington, NA
    Eastell, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (03) : 575 - 585
  • [13] Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study
    Michele Bandirali
    Giovanni Di Leo
    Carmelo Messina
    Maria Juana Pastor Lopez
    Alessandro Mai
    Fabio M. Ulivieri
    Francesco Sardanelli
    Skeletal Radiology, 2015, 44 : 573 - 576
  • [14] SPINE DEFORMITY INDEX ASSESSED BY MORPHOMETRIC X-RAY ABSORPTIOMETRY IN OSTEOPOROTIC PATIENTS - A COMPARATIVE-STUDY
    PFEIFER, M
    POLLAEHNE, W
    MINNE, HW
    JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S376 - S376
  • [15] Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study
    Bandirali, Michele
    Di Leo, Giovanni
    Messina, Carmelo
    Lopez, Maria Juana Pastor
    Mai, Alessandro
    Ulivieri, Fabio M.
    Sardanelli, Francesco
    SKELETAL RADIOLOGY, 2015, 44 (04) : 573 - 576
  • [16] Within-subject variability in body composition using dual-energy X-ray absorptiometry
    DeLorenzo, A
    Andreoli, A
    Candeloro, N
    CLINICAL PHYSIOLOGY, 1997, 17 (04): : 383 - 388
  • [17] Quantification of Visceral Adipose Tissue using Lunar Dual-energy X-ray Absorptiometry in Asian Chinese
    Lin, Huandong
    Yan, Hongmei
    Rao, Shengxiang
    Xia, Mingfeng
    Zhou, Qi
    Xu, Hao
    Rothney, Megan P.
    Xia, Yi
    Wacker, Wynn K.
    Ergun, David L.
    Zeng, Mengsu
    Gao, Xin
    OBESITY, 2013, 21 (10) : 2112 - 2117
  • [18] THE EFFECT OF BONE-SEEKING ELEMENTS PRESENT IN BONE ON DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITIVE ULTRASOUNDMEASUREMENTS: A PHANTOM STUDY
    Jang, D.
    Da Silva, E.
    Tavakkoli, J.
    Slatkovska, L.
    Cheung, A. M.
    Pejovic-Milic, A.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S127 - S127
  • [19] Italian preliminary reference data of normal vertebral dimensions for morphometric X-ray absorptiometry (MXA): Normal morphometric dexa (NORMODEXA) study
    Diacinti, D
    Francucci, C
    Fiore, C
    Rossini, M
    Gibilaro, M
    Zappi, M
    Del Fiacco, R
    D'Erasmo, E
    Mazzuoli, G
    BONE, 2005, 36 : S351 - S351
  • [20] Assessment of the effect of strontium, lead, and aluminum in bone on dual-energy x-ray absorptiometry and quantitative ultrasound measurements: A phantom study
    Jang, Deok Hyun
    Da Silva, Eric
    Tavakkoli, Jahan
    Slatkovska, Lubomira
    Cheung, Angela M.
    Pejovic-Milic, Ana
    MEDICAL PHYSICS, 2018, 45 (01) : 81 - 91