Three-dimensional simulation on the thermal performance of a novel Trombe wall with venetian blind structure

被引:92
|
作者
Hong, Xiaoqiang [1 ]
He, Wei [1 ]
Hu, Zhongting [1 ]
Wang, Chenchen [1 ]
Ji, Jie [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China
关键词
Trombe wall; Three-dimensional simulation; CFD; Heat transfer;
D O I
10.1016/j.enbuild.2014.12.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A complete three-dimensional CFD model was developed to investigate the flow and thermal transport in a novel Trombe wall equipped with a venetian blind. The model was involved in flow and heat transfer in the Trombe wall, which was conjugated with heat conduction in the venetian blind. An experimental rig was constructed and utilized to validate the CFD prediction. It was found that the established model is able to predict the operational performance of the system at a reasonable accuracy. Effect of structural parameters of the Trombe wall was investigated in details under the specific operational condition. The present study indicates that the position of the venetian blind, the width of the air duct and the area of the inlet and outlet vents influence the thermal performance of the system. The results predicted that the optimum of the distance between the glass and the venetian blind is 0.09 m for an air duct of 0.14 m width, the width of the air duct is 0.14 m and the area of each vent is 0.60 m width x 0.10 m height. The research results would assist in developing a high efficient solar air heating system and thus help reduce fossil fuel consumption in the building sector. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 50 条
  • [21] Effect of key parameters on the transient thermal performance of a building envelope with Trombe wall containing phase change material
    Zhou, Shiqiang
    Bai, Fan
    Razaqpur, Ghani
    Wang, Bing
    ENERGY AND BUILDINGS, 2023, 284
  • [22] Experimental measurement and numerical simulation of the thermal performance of a double glazing system with an interstitial Venetian blind
    Sun, Yanyi
    Wu, Yupeng
    Wilson, Robin
    Lu, Sixu
    BUILDING AND ENVIRONMENT, 2016, 103 : 111 - 122
  • [23] Experimental and analytical approach on the Trombe wall thermal performance parameters characterization
    Briga-Sa, Ana
    Boaventura-Cunha, Jose
    Lanzinha, Joao-Carlos
    Paiva, Anabela
    ENERGY AND BUILDINGS, 2017, 150 : 262 - 280
  • [24] Performance prediction of a novel disinfection-enhanced type Trombe wall with transverse fins
    Qian, Yu
    Ji, Jie
    Xie, Hao
    Jia, Hengmin
    Tang, Yayun
    Mu, Yan
    ENERGY, 2024, 302
  • [25] A novel passive method to regulate the performance of photocatalytic-Trombe wall by horizontal fins
    Wu, Shuang-Ying
    Zhao, Yi-Min
    Xiao, Lan
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [26] The performance analysis on a novel purification-cleaning trombe wall based on solar thermal sterilization and thermal catalytic principles
    Yu, Bendong
    Li, Niansi
    Xie, Hao
    Ji, Jie
    ENERGY, 2021, 225
  • [27] EXPERIMENTAL STUDY OF THERMAL PERFORMANCE OF NEW DYNAMIC THERMAL INSULATED PCM TROMBE WALL
    Zhou S.
    Ghani R.A.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (02): : 10 - 15
  • [28] The performance analysis of a novel hybrid solar gradient utilization photocatalytic-thermal-catalytic-Trombe wall system
    Yu, Bendong
    Yang, Jichun
    He, Wei
    Qin, Minghui
    Zhao, Xudong
    Chen, Hongbing
    ENERGY, 2019, 174 : 420 - 435
  • [29] Theoretical study on thermal performance of Trombe wall combined with solar air collector
    Bie, Yu
    Zhou, Fang
    Hu, Ming Fu
    Peng, Qian
    Mao, Wen Yuan
    Chang, Jing Hua
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 208 - +
  • [30] Design, construction and performance testing of a PV blind-integrated Trombe wall module
    Hu, Zhongting
    He, Wei
    Hu, Dengyun
    Lv, Song
    Wang, Liping
    Ji, Jie
    Chen, Hongbing
    Ma, Jinwei
    APPLIED ENERGY, 2017, 203 : 643 - 656