Bone growth in rapid prototyped porous titanium implants

被引:98
作者
Lopez-Heredia, M. A. [2 ]
Goyenvalle, E. [1 ]
Aguado, E. [1 ,3 ]
Pilet, P. [2 ]
Leroux, C. [4 ]
Dorget, M. [4 ]
Weiss, P. [2 ]
Layrolle, P. [2 ]
机构
[1] Ecol Natl Vet Nantes, UPSP, F-44307 Nantes 03, France
[2] Univ Nantes, Fac Chirurg Dentaire, Lab Ingn Osteoarticulaire & Dentaire, INSERM,U791, F-44042 Nantes, France
[3] Fac Med, LHEA, EM0335, INSERM, F-49045 Angers, France
[4] Ctr Transfert Technol Mans, F-72000 Le Mans, France
关键词
rapid prototyping; porous titanium; bone ingrowth; bone apposition;
D O I
10.1002/jbm.a.31468
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two porous titanium implants with a pore size diameter of 800 and 1200 mu m (Ti800 and Ti1200) and an interconnected network were manufactured using rapid prototyping. Their dimensions and structure matched those of the computer assisted design. The porosity of the implants was around 60%. Their compressive strength and Young's modulus were around 80 MPa and 2.7 GPa, respectively. These values are comparable to those of cortical bone. The implants were implanted bilaterally in the femoral epiphysis of 15 New Zealand White rabbits. After 3 and 8 weeks, abundant bone formation was found inside the rapid prototyped porous titanium implants. For the Ti1200 implants, bone ingrowth was (23.9 +/- 3.5)% and (10.3 +/- 2.8)%, respectively. A significant statistical difference (p < 0.05) was found for bone ingrowth in the Ti1200 between the two delays. The percentage of bone directly apposited on titanium was (35.8 +/- 5.4)% and (30.5 +/- 5.0)%. No significant difference was found for bone-implant contact between the different time periods and pore sizes. This work demonstrates that manufacturing macroporous titanium implants with controlled shape and porosity using a rapid prototyping method is possible and that this technique is a good candidate for orthopedic and maxillofacial applications. (C) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:664 / 673
页数:10
相关论文
共 40 条
[21]   Flexible manufacturing of metallic products by selective laser melting of powder [J].
Osakada, Kozo ;
Shiomi, Masanori .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2006, 46 (11) :1188-1193
[22]  
Park J., 2007, Biomaterials-an introduction
[23]   Primary total-hip arthroplasty with the Autophor 900-S fully porous coated stem in young patients - Seven to seventeen years of follow-up [J].
Petsatodes, GE ;
Christoforides, JE ;
Papadopoulos, PP ;
Christodoulou, AG ;
Karataglis, D ;
Pournaras, JD .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :436-442
[24]   Numerical simulation of microstructure evolution of Ti-6Al-4V alloy in vertical centrifugal casting [J].
Ping, Wu Shi ;
Rong, Liu Dong ;
Jie, Guo Jing ;
Yun, Li Chang ;
Qing, Su Yan ;
Zhi, Fu Heng .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2006, 426 (1-2) :240-249
[25]   Electrochemical corrosion and metal ion release from Co-Cr-Mo prosthesis with titanium plasma spray coating [J].
Reclaru, L ;
Eschler, PY ;
Lerf, R ;
Blatter, A .
BIOMATERIALS, 2005, 26 (23) :4747-4756
[26]  
RUSSELL HK, 1972, ARCH PATHOL, V94, P187
[27]   Fabrication methods of porous metals for use in orthopaedic applications [J].
Ryan, G ;
Pandit, A ;
Apatsidis, DP .
BIOMATERIALS, 2006, 27 (13) :2651-2670
[28]   Numerical modeling of pore size and distribution in foamed titanium [J].
Shen, H ;
Oppenheimer, SM ;
Dunand, DC ;
Brinson, LC .
MECHANICS OF MATERIALS, 2006, 38 (8-10) :933-944
[29]   Finite element modeling of porous titanium [J].
Shen, H. ;
Brinson, L. C. .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2007, 44 (01) :320-335
[30]   Design and fabrication of custom mandible titanium tray based on rapid prototyping [J].
Singare, S ;
Li, DC ;
Lu, BG ;
Liu, YP ;
Gong, ZY ;
Liu, YX .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (08) :671-676