Bone growth in rapid prototyped porous titanium implants

被引:98
作者
Lopez-Heredia, M. A. [2 ]
Goyenvalle, E. [1 ]
Aguado, E. [1 ,3 ]
Pilet, P. [2 ]
Leroux, C. [4 ]
Dorget, M. [4 ]
Weiss, P. [2 ]
Layrolle, P. [2 ]
机构
[1] Ecol Natl Vet Nantes, UPSP, F-44307 Nantes 03, France
[2] Univ Nantes, Fac Chirurg Dentaire, Lab Ingn Osteoarticulaire & Dentaire, INSERM,U791, F-44042 Nantes, France
[3] Fac Med, LHEA, EM0335, INSERM, F-49045 Angers, France
[4] Ctr Transfert Technol Mans, F-72000 Le Mans, France
关键词
rapid prototyping; porous titanium; bone ingrowth; bone apposition;
D O I
10.1002/jbm.a.31468
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two porous titanium implants with a pore size diameter of 800 and 1200 mu m (Ti800 and Ti1200) and an interconnected network were manufactured using rapid prototyping. Their dimensions and structure matched those of the computer assisted design. The porosity of the implants was around 60%. Their compressive strength and Young's modulus were around 80 MPa and 2.7 GPa, respectively. These values are comparable to those of cortical bone. The implants were implanted bilaterally in the femoral epiphysis of 15 New Zealand White rabbits. After 3 and 8 weeks, abundant bone formation was found inside the rapid prototyped porous titanium implants. For the Ti1200 implants, bone ingrowth was (23.9 +/- 3.5)% and (10.3 +/- 2.8)%, respectively. A significant statistical difference (p < 0.05) was found for bone ingrowth in the Ti1200 between the two delays. The percentage of bone directly apposited on titanium was (35.8 +/- 5.4)% and (30.5 +/- 5.0)%. No significant difference was found for bone-implant contact between the different time periods and pore sizes. This work demonstrates that manufacturing macroporous titanium implants with controlled shape and porosity using a rapid prototyping method is possible and that this technique is a good candidate for orthopedic and maxillofacial applications. (C) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:664 / 673
页数:10
相关论文
共 40 条
[1]  
BRAM M, 2005, MATER FORUM, P119
[2]  
Brettle J, 1970, Injury, V2, P26, DOI 10.1016/S0020-1383(70)80110-3
[3]   In vitro biological effects of titanium rough surface obtained by calcium phosphate grid blasting [J].
Citeau, A ;
Guicheux, J ;
Vinatier, C ;
Layrolle, P ;
Nguyen, TP ;
Pilet, P ;
Daculsi, G .
BIOMATERIALS, 2005, 26 (02) :157-165
[4]   Processing of titanium foams [J].
Dunand, DC .
ADVANCED ENGINEERING MATERIALS, 2004, 6 (06) :369-376
[5]  
Frost HM, 2004, ANGLE ORTHOD, V74, P3
[6]   Osteoinduction of porous bioactive titanium metal [J].
Fujibayashi, S ;
Neo, M ;
Kim, HM ;
Kokubo, T ;
Nakamura, T .
BIOMATERIALS, 2004, 25 (03) :443-450
[7]   COMPUTER-GENERATED MODEL SURGERY - AN EXACTING APPROACH TO COMPLEX CRANIOMAXILLOFACIAL DISHARMONIES [J].
GUYURON, B ;
ROSS, RJ .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1989, 17 (03) :101-104
[8]   Biological performance of uncoated and octacalcium phosphate-coated Ti6A14V [J].
Habibovic, P ;
Li, JP ;
van der Valk, CM ;
Meijer, G ;
Layrolle, P ;
van Blitterswijk, CA ;
de Groot, K .
BIOMATERIALS, 2005, 26 (01) :23-36
[9]   Structural, mechanical and in vitro characterization of individually structured Ti-6Al-4V produced by direct laser forming [J].
Hollander, DA ;
von Walter, M ;
Wirtz, T ;
Sellei, R ;
Schmidt-Rohlfing, B ;
Paar, O ;
Erli, HJ .
BIOMATERIALS, 2006, 27 (07) :955-963
[10]   Porosity of 3D biomaterial scaffolds and osteogenesis [J].
Karageorgiou, V ;
Kaplan, D .
BIOMATERIALS, 2005, 26 (27) :5474-5491