Failure Region Estimation of the Linear Voltage Regulator Using Model-Based Approach

被引:0
作者
Raihan, Muhammad Fauzi Mohd [1 ]
Zamri, Syukri [1 ]
Zaman, Mohd Hairi Mohd [1 ]
Mustafa, M. Marzuki [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Bangi, Selangor, Malaysia
来源
2021 INTERNATIONAL CONFERENCE ON DECISION AID SCIENCES AND APPLICATION (DASA) | 2021年
关键词
linear voltage regulator; failure region; system identification; neural network; effectiveness; efficiency;
D O I
10.1109/DASA53625.2021.9682246
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Linear voltage regulator (LVR) stability in electronic devices depends on the LVR's internal circuit design and output capacitor, with the specific equivalent series resistance (ESR) values being influenced by the LVR's output terminal. ESR variation due to temperature change and aging factors creates an LVR failure region in the ESR tunnel graph. However, the LVR failure region estimation process is being conducted manually, which consumes high manufacturing time and requires high skill expertise. Furthermore, LVRs differ in their exact models, and manufacturers hardly know the exact internal parametric values of these manufactured LVRs because of the manufacturing variation factor. The objective of this study is to develop a model-based failure region estimation (FRE) method to ensure the efficiency and effectiveness of the FRE process. In this study, the FRE process was initially manually conducted and used as the benchmark. Then, the manually obtained FRE process data were used in the model-based FRE method by integrating the system identification method into the neural network. Finally, the two methods (manual FRE and model-based FRE) were compared. The effectiveness of the model-based FRE was high, with error values approaching zero and an approximate accuracy of 100%. As for efficiency, the model-based FRE was 43.75% faster than the manual FRE. These outcomes indicate that the model-based FRE is suitable for LVR manufacturing. Therefore, LVR manufacturers can test each LVR failure region with better efficiency and effectiveness by adopting the developed FRE method.
引用
收藏
页数:7
相关论文
共 15 条
[1]   Critical ESR of output capacitor for stability of fixed off-time controlled buck converter [J].
Bao, B. C. ;
Zhang, X. ;
Xu, J. P. ;
Wang, J. P. .
ELECTRONICS LETTERS, 2013, 49 (04) :287-288
[2]  
Basso C, 2012, DESIGNING CONTROL LOOPS FOR LINEAR AND SWITCHING POWER SUPPLIES: A TUTORIAL GUIDE, P1
[3]   A frequency compensation scheme for LDO voltage regulators [J].
Chava, CK ;
Silva-Martínez, J .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2004, 51 (06) :1041-1050
[4]  
Ibrahim M. F., 2019, INT J ADV TRENDS COM, V8, P167
[5]  
Lee B. S, 1999, TEXAS INSTRUMENTS AP, P1
[6]  
Lee B. S., 1999, ANALOG APPL J, V1, P14
[7]  
Luet NL, 2020, INT J ADV COMPUT SC, V11, P580
[8]  
Musa AH, 2014, 2014 IEEE CONFERENCE ON SYSTEMS, PROCESS AND CONTROL (ICSPC 2014), P68, DOI 10.1109/SPC.2014.7086232
[9]  
Mustafa N., 2015, PRZ ELEKTROTECHNICZN, V1, P28
[10]  
Rogers E, 1999, ANALOG APPL J AUG, P10