Clinical feasibility of diffuse speckle contrast analysis for real-time tissue perfusion monitoring

被引:2
作者
Awopetu, Ayoola, I [1 ]
Gohel, Manjit S. [1 ]
Sadat, Umar [1 ]
Hayes, Paul D. [2 ]
机构
[1] Cambridge Univ Hosp, Dept Vasc Surg, Cambridge, England
[2] St Johns Innovat Ctr, Cowley Rd, Cambridge CB4 0WS, England
关键词
Laser speckle contrast imaging; Perfusion; Extremities; Ischemia; Peripheral arterial disease;
D O I
10.23736/S0392-9590.21.04740-4
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Adequate tissue perfusion is an important prognostic and diagnostic factor during the management of lower limb peripheral arterial disease. Convenient and real-time tissue perfusion monitoring remains an elusive challenge. Methods: Tissue perfusion on the dorsal and plantar surfaces of both feet of 20 participants was measured during and after cuff-induced ischemia using a novel 4-channel, laser-based perfusion monitoring device based on diffuse speckle contrast analysis technology (Pedra sensors). Participants were free of significant peripheral arterial disease. Transcutaneous partial pressure of oxygen (TcPO2) measurements were recorded concurrently for comparison. Results: Pedra sensors detected perfusion changes significantly more quickly than TcPO2 sensors. One minute after induced ischemia, the mean percent changes from baseline values (before ischemia) were-22.7 +/- 32.0% and-3.1 +/- 8.8% (P<0.001) for Pedra and TcPO2 sensors, respectively. One minute into induced ischemia, Pedra sensors had reached 50.5% of the 5-minute ischemia reading whereas TcPO2 sensors had reached only 18.6% of the 5-minute reading (P=0.046). Pedra sensors reported hyperemia immediately after cuff release with a mean percent change from baseline of 143.8 +/- 122.3%/173.4 +/- 121.8% on the dorsal/plantar surfaces while TcPO2 measurements were still recording negative changes at that time (-26.7 +/- 19.4%/-18.6 +/- 24.4% dorsal/plantar). Pedra sensors exhibited markedly lower interobserver and intraobserver variability than TcPO2 sensors. Conclusions: A device based on diffuse speckle contrast analysis reported tissue perfusion in real time. Cuff-induced ischemia and hyperemia following cuff release were rapidly and consistently detected on both the dorsal and plantar surfaces of the foot. Diffuse speckle contrast analysis may have value for real-time perfusion monitoring during angiography procedures.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 12 条
[1]   Microvascular imaging: techniques and opportunities for clinical physiological measurements [J].
Allen, John ;
Howell, Kevin .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (07) :R91-R141
[2]   Predictors of Wound Healing Following Revascularization for Chronic Limb-Threatening Ischemia [J].
Antonopoulos, Constantine N. ;
Lazaris, Andreas ;
Venermo, Maarit ;
Geroulakos, George .
VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (08) :649-657
[3]   Multi-channel deep tissue flowmetry based on temporal diffuse speckle contrast analysis [J].
Bi, Renzhe ;
Dong, Jing ;
Lee, Kijoon .
OPTICS EXPRESS, 2013, 21 (19) :22854-22861
[4]   Deep tissue flowmetry based on diffuse speckle contrast analysis [J].
Bi, Renzhe ;
Dong, Jing ;
Lee, Kijoon .
OPTICS LETTERS, 2013, 38 (09) :1401-1403
[5]   Review of laser speckle contrast techniques for visualizing tissue perfusion [J].
Draijer, Matthijs ;
Hondebrink, Erwin ;
van Leeuwen, Ton ;
Steenbergen, Wiendelt .
LASERS IN MEDICAL SCIENCE, 2009, 24 (04) :639-651
[6]   Clinical applications of laser speckle contrast imaging: a review [J].
Heeman, Wido ;
Steenbergen, Wiendelt ;
van Dam, Gooitzen M. ;
Boerma, E. Christiaan .
JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (08)
[7]   Low-cost compact diffuse speckle contrast flowmeter using small laser diode and bare charge-coupled-device [J].
Huang, Chong ;
Seong, Myeongsu ;
Morgan, Joshua Paul ;
Mazdeyasna, Siavash ;
Kim, Jae Gwan ;
Hastings, Jeffrey Todd ;
Yu, Guoqiang .
JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)
[8]   Perfusion Assessment in Critical Limb Ischemia: Principles for Understanding and the Development of Evidence and Evaluation of Devices: A Scientific Statement From the American Heart Association [J].
Misra, Sanjay ;
Shishehbor, Mehdi H. ;
Takahashi, Edwin A. ;
Aronow, Herbert D. ;
Brewster, Luke P. ;
Bunte, Matthew C. ;
Kim, Esther S. H. ;
Lindner, Jonathan R. ;
Rich, Kathleen .
CIRCULATION, 2019, 140 (12) :E657-E672
[9]  
Petzelbauer P., 2019, Fitzpatricks Dermatology, V9th, P116
[10]   Clinical applications of near-infrared diffuse correlation spectroscopy and tomography for tissue blood flow monitoring and imaging [J].
Shang, Yu ;
Li, Ting ;
Yu, Guoqiang .
PHYSIOLOGICAL MEASUREMENT, 2017, 38 (04) :R1-R26