Comparison of electrocardiogram quality and clinical interpretations using prepositioned ECG electrodes and conventional individual electrodes

被引:9
作者
Roy, Sion K. [1 ,2 ]
Shah, Sonia U. [1 ,2 ]
Villa-Lopez, Eva [2 ]
Murillo, Mary [2 ]
Arenas, Nataly [2 ]
Oshima, Karin [2 ]
Chang, Ruey-Kang [2 ]
Lauzon, Marie [3 ]
Guo, Xiuqing [3 ]
Pillutla, Priya [1 ,2 ]
机构
[1] Harbor UCLA Med Ctr, Dept Med, Div Cardiol, 1124 W Carson St, Torrance, CA 90502 USA
[2] Harbor UCLA Med Ctr, Lundquist Inst, Torrance, CA USA
[3] Harbor UCLA Med Ctr, Lundquist Inst, Inst Translat Genom & Populat Sci, Torrance, CA USA
关键词
Pre-positioned electrodes; ECG; Equivalence study; HEART-ASSOCIATION ELECTROCARDIOGRAPHY; OF-CARDIOLOGY-FOUNDATION; 12-LEAD ELECTROCARDIOGRAM; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; PRECORDIAL LEADS; RHYTHM-SOCIETY; PLACEMENT; STANDARDIZATION; RECOMMENDATIONS;
D O I
10.1016/j.jelectrocard.2020.02.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Efforts have been made to simplify and reduce technical errors, such as limb leads reversal and inaccurate chest leads placement, for the 12-lead ECG tests. We compared standard ECG using individual electrodes with a novel pre-positioned electrode system to determine equivalency. Methods: Subjectswere recruited from the Emergency Department and cardiac lab of an acute care hospital in Los Angeles. First, subjects underwent a conventional 12-lead ECG using Philips PageWriter (clinical ECG). A second ECG was then performed using a novel system containing pre-positioned electrodes and a compact recorder (study ECG). All ECGs were reviewed by 3 blinded, board-certified adult cardiologists using 14 pre-specified ECG diagnostic categories to determine if the interpretations of clinical ECG and study ECG of the same patient were "equivalent". Majority rule was applied when there were discrepant interpretations among the 3 cardiologists. Results: One hundred subjects, ages 18 to 74 completed the study. With pre-positioned electrodes, the rate of "electrode fit" as judged by the research associates at the time of lead placement was 96.2%. We found that the study ECG system was equivalent (in clinical interpretation) to the clinical ECG system, with equivalency rate of 96% (95% confidence interval 92% to 100%) in "overall interpretation". The equivalence rate for the 14 ECG diagnostic categories ranged from 96% to 100%, with mean 99.2 +/- 1.1%. Conclusions: 12-lead ECGs performed using single-piece, pre-positioned electrodes are clinically equivalent to those performed using 10 individually placed conventional electrodes. With 4 sizes for adults, the single-piece electrodes can fit 96% of the study patients. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:126 / 133
页数:8
相关论文
共 19 条
  • [1] 12-lead ECG training: The way forward
    Alinier, G
    Gordon, R
    Harwood, C
    Hunt, WB
    [J]. NURSE EDUCATION TODAY, 2006, 26 (01) : 87 - 92
  • [2] The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram
    Bond, R. R.
    Finlay, D. D.
    Nugent, C. D.
    Breen, C.
    Guldenring, D.
    Daly, M. J.
    [J]. EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2012, 23 (07) : 610 - 615
  • [3] FACTORS AFFECTING THE RELATIONSHIP BETWEEN PRECORDIAL ELECTROCARDIOGRAPHIC VOLTAGE AND LEFT-VENTRICULAR WALL THICKNESS
    DANCY, M
    [J]. EUROPEAN HEART JOURNAL, 1987, 8 (06) : 587 - 591
  • [4] Detection of frequently overlooked electrocardiographic lead reversals using artificial neural networks
    Heden, B
    Ohlsson, M
    Holst, H
    Mjoman, M
    Rittner, R
    Pahlm, O
    Peterson, C
    Edenbrandt, L
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (05) : 600 - &
  • [5] HILL NE, 1987, HEART LUNG, V16, P561
  • [6] Jevon Phil, 2010, Br J Nurs, V19, P649
  • [7] The effect of precordial lead displacement on ECG morphology
    Kania, Michal
    Rix, Herve
    Fereniec, Malgorzata
    Zavala-Fernandez, Heriberto
    Janusek, Dariusz
    Mroczka, Tomasz
    Stix, Guenter
    Maniewski, Roman
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (02) : 109 - 119
  • [8] Recommendations for the standardization and interpretation of the electrocardiogram - Part I: The electrocardiogram and its technology - A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society - Endorsed by the International Society for Computerized Electrocardiology
    Kligfield, Paul
    Gettes, Leonard S.
    Bailey, James J.
    Childers, Rory
    Deal, Barbara J.
    Hancock, E. William
    van Herpen, Gerard
    Kors, Jan A.
    Macfarlane, Peter
    Mirvis, David M.
    Pahlm, Olle
    Rautaharju, Pentti
    Wagner, Galen S.
    [J]. CIRCULATION, 2007, 115 (10) : 1306 - 1324
  • [9] Home use of a compact, 12-lead ECG recording system for newborns
    Lin, Henry J.
    Lan, Yueh-Tze
    Silka, Michael J.
    Halnon, Nancy J.
    Villa-Lopez, Eva
    Arenas, Nataly
    Escobedo, Fabian
    Montoya, Ryan
    Valdez, Sarah
    Shishvan, Omid Rajabi
    Sedano, Sandra
    Marr, Emily H.
    Lauzon, Marie
    Moosa, A. S.
    Ko, Kimberly J.
    Shoji, Elaine C.
    Clark, Alexandra M.
    Smith, Lynne M.
    Criley, John Michael
    Grody, Wayne W.
    Chen, Yii-Der Ida
    Taylor, Kent D.
    Guo, Xiuqing
    Soyata, Tolga
    Rotter, Jerome I.
    Chien, Tingchou
    Chou, Pai
    Chang, Ruey-Kang
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2019, 53 : 89 - 94
  • [10] Comparison of Twelve-Lead Electrocardiogram Using a Glove-Based Recording System With Standard Methodology
    Luc, Michael
    Fintel, Dan J.
    Klein, Herman O.
    Childers, Roderick
    Mor-Avi, Victor
    Tzivoni, Dan
    Lang, Roberto M.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (06) : 895 - 903