Optimization and application of high-resolution gas chromatography with ion trap tandem mass spectrometry to the determination of polychlorinated biphenyls in atmospheric aerosols

被引:46
|
作者
Mandalakis, M [1 ]
Tsapakis, M [1 ]
Stephanou, EG [1 ]
机构
[1] Univ Crete, Dept Chem, ECPL, Iraklion 71409, Greece
关键词
aerosols; air analysis; environmental analysis; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(01)01033-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optimization of the Finnigan GCQ ion trap mass spectrometry (ITMS) system and a clean-up procedure were carried out in order to apply high-resolution gas chromatography-tandem mass spectrometry for the analysis of polychlorinated biphenyls (PCBs) in aerosols. Six ITMS operating parameters, including isolation time, excitation voltage, excitation time, "q" value, ion source temperature and electron energy were adjusted in order to optimize the instrument analytical performance. The adjustment of all parameters substantially increased the sensitivity of ITMS in the MS-MS mode. Changes in isolation time did not particularly affect ITMS sensitivity while ion source temperature had the strongest influence. After optimization, a limit of detection of 600 fg/mul with S/N varying from 8 up to 91 was achieved. The application of the optimized ITMS parameters conjointly with the developed clean-up procedure resulted in method detection limits of 10-20 fg/m(3) for the determination of PCBs, in the particulate and gas phase of the atmospheric aerosol of background areas in the Eastern Mediterranean and Sweden. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:183 / 196
页数:14
相关论文
共 50 条
  • [1] Determination of hydroxylated polychlorinated biphenyls by ion trap gas chromatography tandem mass spectrometry
    Abraham, VM
    Lynn, BC
    JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) : 131 - 141
  • [2] Feasibility of gas chromatography -: ion trap tandem mass spectrometry for the determination of polychlorinated biphenyls in food
    Gómara, B
    Fernández, MA
    González, MJ
    Ramos, L
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) : 123 - 130
  • [3] Determination of polar organic compounds in atmospheric aerosols by gas chromatography with ion trap tandem mass spectrometry
    Visentin, Marco
    Pietrogrande, Maria Chiara
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (13) : 1561 - 1569
  • [4] Gas chromatography-ion trap tandem mass spectrometry versus GC-high-resolution mass spectrometry for the determination of non-ortho-polychlorinated biphenyls in fish
    Malavia, J
    Santos, E
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) : 171 - 178
  • [5] Determination of polycholorinated biphenyls in fish by gas chromatography-ion trap tandem mass spectrometry
    Li, JG
    Zhao, YF
    Wu, YN
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (09) : 1223 - 1226
  • [6] The performance of atmospheric pressure gas chromatography-tandem mass spectrometry compared to gas chromatography-high resolution mass spectrometry for the analysis of polychlorinated dioxins and polychlorinated biphenyls in food and feed samples
    ten Dam, Guillaume
    Pussente, Igor Cabreira
    Scholl, Georges
    Eppe, Gauthier
    Schaechtele, Alexander
    van Leeuwen, Stefan
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1477 : 76 - 90
  • [7] Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers
    Fang, Jing
    Zhao, Hongzhi
    Zhang, Yanhao
    Wong, Minghung
    He, Yu
    Sun, Qianqian
    Xu, Shunqing
    Cai, Zongwei
    CHEMOSPHERE, 2019, 225 : 288 - 294
  • [8] IDENTIFICATION AND DETERMINATION OF POLYCHLORINATED-BIPHENYLS BY HIGH-RESOLUTION GAS-CHROMATOGRAPHY
    ONUSKA, FI
    KOMINAR, RJ
    TERRY, KA
    JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV): : 111 - 118
  • [9] Ion-trap mass spectrometry used in combination with gas chromatography for high-resolution metabolic flux determination
    Klapa, MI
    Aon, JC
    Stephanopoulos, G
    BIOTECHNIQUES, 2003, 34 (04) : 832 - +
  • [10] Comparison of gas chromatography-ion-trap tandem mass spectrometry systems for the determination of polychlorinated dibenzo-p-dioxins, dibenzofurans and dioxin-like polychlorinated biphenyls
    Malavia, J.
    Santos, F. J.
    Galceran, M. T.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 302 - 311