Time and temperature sensitivity of the Hybrid III neck

被引:5
作者
Schmidt, Allison L. [1 ]
Ortiz-Paparoni, Maria A. [1 ]
Shridharani, Jay K. [1 ]
Nightingale, Roger W. [1 ]
Bass, Cameron R. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Injury Biomech Lab, 1427 CIEMAS Bldg,Box 90281, Durham, NC 27708 USA
关键词
Compression; hybrid III; neck; repeatability; stiffness; temperature; IMPACTS; ATD;
D O I
10.1080/15389588.2018.1480832
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The Hybrid III (HIII) dummy is one of the most widely used anthropomorphic test devices (ATDs) in the world, and researchers have found a variety of uses for it outside of its original purpose as an automotive crash test dummy. These expanded roles have introduced situations outside the dummy's original design parameters, where a number of tests must be run in relatively rapid succession or where it may not be possible to control the temperature of the test environment.Objective: This study has 2 aims. The first is to determine how the duration of the time interval between tests affects the axial compression performance of the HIII neck. The second is to quantify the effect of temperature on the neck's compressive stiffness through a range of temperatures relevant to indoor or outdoor testing.Methods: To characterize the effects of different test conditions, a series of high-rate axial compressive tests was run on a 50th percentile male HIII neck component in a materials testing machine. Between-test recovery intervals were varied from 2h to 1min, and temperature conditions of 0, 12.5, 25, and 37.5 degrees C were tested.Results: Though the duration of the recovery interval had little impact on the recorded force (less than 1%), the component did exhibit considerable strain creep over the course of the test. Temperature had a strong influence on the compressive stiffness of the component. Compared to the stiffness at 25 degrees C (near room temperature), the stiffness of the neck at 37.5 degrees C fell by 15%; at 0 degrees C, the stiffness more than doubled.Conclusions: This study demonstrates that though the duration of the recovery interval between tests has a small influence on neck stiffness, temperature effects should not be overlooked because they influence neck compressive stiffness considerably. The relationship between recorded force and temperature is well represented by exponential decay models. These findings highlight the importance of monitoring and controlling for temperature effects during all HIII testing.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 18 条
[1]   Hybrid III anthropomorphic test device (ATD) response to head impacts and potential implications for athletic headgear testing [J].
Bartsch, Adam ;
Benzel, Edward ;
Miele, Vincent ;
Morr, Douglas ;
Prakash, Vikas .
ACCIDENT ANALYSIS AND PREVENTION, 2012, 48 :285-291
[2]  
Bass C., 2007, INT RES COUNC BIOM I
[3]  
Caccese V, 2016, EXP TECHNIQUES, V40, P413, DOI [10.1111/ext.12079, 10.1007/s40799-016-0046-4]
[4]  
Foster J., 1994, HYBRID III: THE FIRST HUMAN-LIKE CRASH TEST DUMMY, P49
[5]   Hybrid III ATD in Inverted Impacts: Influence of Impact Angle on Neck Injury Risk Assessment [J].
Frechede, B. ;
McIntosh, A. ;
Grzebieta, R. ;
Bambach, M. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (07) :1403-1414
[6]  
Hooper CD., 1964, Low-temperature elastic behavior of fourteen compounded elastomers
[7]  
Humanetics Innovative Solutions, 2015, LOAD CELL CAL REP MO
[8]   Viscoelastic properties of the cervical spinal ligaments under fast strain-rate deformations [J].
Lucas, Scott R. ;
Bass, Cameron R. ;
Salzar, Robert S. ;
Oyen, Michelle L. ;
Planchak, Chris ;
Ziemba, Adam ;
Shender, Barry S. ;
Paskoff, Glenn .
ACTA BIOMATERIALIA, 2008, 4 (01) :117-125
[9]  
Mason P., 1961, Journal of Applied Polymer Science, V5, P428, DOI DOI 10.1002/APP.1961.070051608
[10]  
Mates S., 2018, DYNAMIC BEHAV MAT, V1, P57