On-line Micro-Packed Column Solid-Phase Extraction of Cadmium Using MetalOrganic Framework (MOF) UiO-66 with Posterior Determination by TS-FF-AAS

被引:9
|
作者
Carneiro, Ana Carla R. [1 ]
Meneguin, Joziane G. [1 ]
dos Santos, Paula M. [1 ]
Corazza, Marcela Z. [1 ]
Prete, Maiyara Carolyne [1 ]
Rinaldi, Andrelson Wellington [2 ]
Tarley, Cesar Ricardo T. [1 ,3 ]
机构
[1] Univ Estadual Londrina, Dept Quim, Rodovia Celso Garcia Cid,PR 445 Km 380, BR-86051990 Londrina, Parana, Brazil
[2] Univ Estadual Maringa, Dept Quim, Av Colombo,Campus Univ, BR-87020900 Maringa, Parana, Brazil
[3] Univ Estadual Campinas, Inst Nacl Ciencia & Tecnol Bioanalit INCT BIO, UNICAMP, Dept Quim Analit,Inst Quim, Cidade Univ Zeferino Vaz, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
FIA system; metal-organic framework; UiO-66; TS-FF-AAS; cadmium; METAL-ORGANIC FRAMEWORKS; PERFORMANCE LIQUID-CHROMATOGRAPHY; WATER SAMPLES; PRECONCENTRATION SYSTEM; SPECIATION ANALYSIS; CARBON NANOTUBES; GRAPHENE OXIDE; SORBENT; ADSORPTION; NANOPARTICLES;
D O I
10.21577/0103-5053.20220049
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Metal-organic framework (MOF) UiO-66 was synthesized and evaluated as solid-phase extractor support for cadmium preconcentration in a micro-flow injection system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) detection. The adsorbent was characterized by X-ray diffraction, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), Raman spectroscopy, and textural data from N-2 adsorption/desorption isotherm data. The optimized conditions were achieved by loading 10.0 mL of a sample, containing 0.05 mol L-1 of phosphate buffer solution at pH 8.0, at a high flow rate of 10.0 mL(-1) through 20.0 mg of UiO-66 packed into a mini-column, followed by elution with 1.0 mol L-1 HCl. At these conditions, the method presented a preconcentration factor of 35.7, limit of detection of 0.03 mu g L-1 and a dynamic linear range from 0.1 to 8.0 mu g L-1. The adsorption performance of UiO-66 towards cadmium was not influenced by Pb2+, Hg2+, Fe2+, Co2+, Cu2+, Ni2+, Zn2+, Mg2+ and Ca2+ ions. Analysis of different waters samples (tap water, physiological solution, mineral water, and lake water) was carried out without matrix interference, yielding recovery values ranging from 92.0 to 111.9%.
引用
收藏
页码:958 / 968
页数:11
相关论文
共 22 条
  • [11] Determination of 15 amide herbicides in rice using monolith column for on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry
    Zhang Haichao
    Ai Lianfeng
    Ma Yusong
    Wang Jing
    Li Xiaofei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (10) : 991 - 998
  • [12] Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals in environmental samples
    Huang, Chaozhang
    Jiang, Zucheng
    Hu, Bin
    TALANTA, 2007, 73 (02) : 274 - 281
  • [13] On-line Solid Phase Extraction of Nickel, Copper, and Cadmium Using a Newly Synthesized Polyamine Silica Gel-loaded Mini-column for Flame Atomic Absorption Spectrometric Determination
    Sivrikaya, Sezen
    Imamoglu, Mustafa
    Kara, Derya
    ATOMIC SPECTROSCOPY, 2014, 35 (04) : 168 - 176
  • [14] Determination of fenbufen and its metabolites in serum by reversed-phase high-performance liquid chromatography using solid-phase extraction and on-line post-column ultraviolet irradiation and fluorescence detection
    Siluveru, M
    Stewart, JT
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (01): : 89 - 94
  • [15] Flow injection solid-phase extraction using multi-walled carbon nanotubes packed micro-column for the determination of polycyclic aromatic hydrocarbons in water by gas chromatography-mass spectrometry
    Wu, Hong
    Wang, Xuecui
    Liu, Bing
    Lu, Jie
    Du, Baixiang
    Zhang, Luxin
    Ji, Jingjing
    Yue, Qiaoyu
    Han, Baoping
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) : 2911 - 2917
  • [16] Trace-level determination of pesticide residues using on-line solid-phase extraction-column liquid chromatography with atmospheric pressure ionization mass spectrometric and tandem mass spectrometric detection
    Slobodnik, J
    Hogenboom, AC
    Vreuls, JJ
    Rontree, JA
    vanBaar, BLM
    Niessen, WMA
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) : 59 - 74
  • [17] Dispersive Solid-Phase Extraction Using Microporous Sorbent UiO-66 Coupled to Gas Chromatography-Tandem Mass Spectrometry: A QuEChERS-Type Method for the Determination of Organophosphorus Pesticide Residues in Edible Vegetable Oils without Matrix Interference
    Mao, Xuejin
    Yan, Aiping
    Wan, Yiqun
    Luo, Dongmei
    Yang, Hongshun
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (06) : 1760 - 1770
  • [18] Development of ligandless dispersive micro-solid-phase extraction method based on NH2-UiO-66 (Zr) MOF using DES eluent in determination of Cd(II) and Cu(II) ions in water and fruit juice samples
    Morvaridi, Mahsa
    Sorouraddin, Saeed Mohammad
    Mogaddam, Mohammad Reza Afshar
    Farajzadeh, Mir Ali
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023,
  • [19] Simultaneous speciation of inorganic arsenic and antimony in water samples by hydride generation-double channel atomic fluorescence spectrometry with on-line solid-phase extraction using single-walled carbon nanotubes micro-column
    Wu, Hong
    Wang, Xuecui
    Liu, Bing
    Liu, Yueling
    Li, Shanshan
    Lu, Jusheng
    Tian, Jiuying
    Zhao, Wenfeng
    Yang, Zonghui
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (01) : 74 - 80
  • [20] Performance improvements in the determination of mercury species in natural gas condensate using an on-line amalgamation trap or solid-phase micro-extraction with capillary gas chromatography-microwave-induced plasma atomic emission spectrometry
    Snell, JP
    Frech, W
    Thomassen, Y