On-line Micro-Packed Column Solid-Phase Extraction of Cadmium Using MetalOrganic Framework (MOF) UiO-66 with Posterior Determination by TS-FF-AAS

被引:9
|
作者
Carneiro, Ana Carla R. [1 ]
Meneguin, Joziane G. [1 ]
dos Santos, Paula M. [1 ]
Corazza, Marcela Z. [1 ]
Prete, Maiyara Carolyne [1 ]
Rinaldi, Andrelson Wellington [2 ]
Tarley, Cesar Ricardo T. [1 ,3 ]
机构
[1] Univ Estadual Londrina, Dept Quim, Rodovia Celso Garcia Cid,PR 445 Km 380, BR-86051990 Londrina, Parana, Brazil
[2] Univ Estadual Maringa, Dept Quim, Av Colombo,Campus Univ, BR-87020900 Maringa, Parana, Brazil
[3] Univ Estadual Campinas, Inst Nacl Ciencia & Tecnol Bioanalit INCT BIO, UNICAMP, Dept Quim Analit,Inst Quim, Cidade Univ Zeferino Vaz, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
FIA system; metal-organic framework; UiO-66; TS-FF-AAS; cadmium; METAL-ORGANIC FRAMEWORKS; PERFORMANCE LIQUID-CHROMATOGRAPHY; WATER SAMPLES; PRECONCENTRATION SYSTEM; SPECIATION ANALYSIS; CARBON NANOTUBES; GRAPHENE OXIDE; SORBENT; ADSORPTION; NANOPARTICLES;
D O I
10.21577/0103-5053.20220049
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Metal-organic framework (MOF) UiO-66 was synthesized and evaluated as solid-phase extractor support for cadmium preconcentration in a micro-flow injection system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) detection. The adsorbent was characterized by X-ray diffraction, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), Raman spectroscopy, and textural data from N-2 adsorption/desorption isotherm data. The optimized conditions were achieved by loading 10.0 mL of a sample, containing 0.05 mol L-1 of phosphate buffer solution at pH 8.0, at a high flow rate of 10.0 mL(-1) through 20.0 mg of UiO-66 packed into a mini-column, followed by elution with 1.0 mol L-1 HCl. At these conditions, the method presented a preconcentration factor of 35.7, limit of detection of 0.03 mu g L-1 and a dynamic linear range from 0.1 to 8.0 mu g L-1. The adsorption performance of UiO-66 towards cadmium was not influenced by Pb2+, Hg2+, Fe2+, Co2+, Cu2+, Ni2+, Zn2+, Mg2+ and Ca2+ ions. Analysis of different waters samples (tap water, physiological solution, mineral water, and lake water) was carried out without matrix interference, yielding recovery values ranging from 92.0 to 111.9%.
引用
收藏
页码:958 / 968
页数:11
相关论文
共 22 条
  • [1] On-line Micro-Packed Column Solid-Phase Extraction of Cadmium Using Metal-Organic Framework (MOF) UiO-66 with Posterior Determination by TS-FF-AAS
    Carneiro, Ana Carla R.
    Meneguin, Joziane G.
    dos Santos, Paula M.
    Corazza, Marcela Z.
    Prete, Maiyara Carolyne
    Rinaldi, Andrelson Wellington
    Tarley, Cesar Ricardo T.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2022, 33 (07) : 958 - 968
  • [2] On-line micro-solid phase preconcentration of Cd2+ coupled to TS-FF-AAS using a novel ion-selective bifunctional hybrid imprinted adsorbent
    Teixeira Tarley, Cesar Ricardo
    Corazza, Marcela Zanetti
    de Oliveira, Fernanda Midori
    Somera, Bruna Fabrin
    Nascentes, Clesia Cristina
    Segatelli, Mariana Gaya
    MICROCHEMICAL JOURNAL, 2017, 131 : 57 - 69
  • [3] ON-LINE MINI-COLUMN SOLID-PHASE EXTRACTION COUPLED WITH SEQUENTIAL INJECTION FOR THE DETERMINATION OF CADMIUM IN ENVIRONMENTAL SAMPLES
    Zhu, Guifen
    Wang, Haibo
    Gao, Xia
    Fan, Jing
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (03) : 320 - 330
  • [4] Determination of lead by on-line solid phase extraction using a PTFE micro-column and flame atomic absorption spectrometry
    Zachariadis, GA
    Anthemidis, AN
    Bettas, PG
    Stratis, JA
    TALANTA, 2002, 57 (05) : 919 - 927
  • [5] On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples
    Anthemidis, AN
    Zachariadis, GA
    Stratis, JA
    TALANTA, 2001, 54 (05) : 935 - 942
  • [6] Determination of nicardipine and amlodipine in human plasma using on-line solid-phase extraction with a monolithic weak cation-exchange column
    Wei, Xiaoyi
    Yang, Gengliang
    Qi, Li
    Chen, Yi
    TALANTA, 2009, 77 (03) : 1197 - 1202
  • [7] Determination of aspirin and salicylic acid in human plasma by column-switching liquid chromatography using on-line solid-phase extraction
    McMahon, GP
    Kelly, MT
    ANALYTICAL CHEMISTRY, 1998, 70 (02) : 409 - 414
  • [8] Dispersive solid-phase extraction using microporous metal-organic framework UiO-66: Improving the matrix compounds removal for assaying pesticide residues in organic and conventional vegetables
    Mao, Xuejin
    Xiao, Weiming
    Wan, Yiqun
    Li, Zhanming
    Luo, Dongmei
    Yang, Hongshun
    FOOD CHEMISTRY, 2021, 345
  • [9] Sensitive and accurate determination of sialic acids in serum with the aid of dispersive solid-phase extraction using the zirconium-based MOF of UiO-66-NH2 as sorbent
    Qu, Fengli
    Xia, Lian
    Wu, Chuanxiang
    Liu, Lijie
    Li, Guoliang
    You, Jinmao
    RSC ADVANCES, 2016, 6 (69): : 64895 - 64901
  • [10] Determination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column
    Anthemidis, Aristidis N.
    Martavaltzoglou, Evdoxia K.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 413 - 418