Respiratory-gated segment reconstruction for radiation treatment planning using 256-slice CT-scanner during free breathing

被引:2
作者
Mori, S [1 ]
Endo, M [1 ]
Kohno, R [1 ]
Minohara, S [1 ]
Kohno, K [1 ]
Asakura, H [1 ]
Fujiwara, H [1 ]
Murase, K [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
来源
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2 | 2005年 / 5745卷
关键词
respiration; target volume; dynamic data; image quality; temporal resolution; HOLD TECHNIQUE; PERFORMANCE EVALUATION; IRRADIATION SYSTEM; MOTION; RADIOTHERAPY; THERAPY; CANCER;
D O I
10.1117/12.596632
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conventional respiratory-gated CT scan technique includes anatomic motion induced artifacts due to the low temporal resolution. They are a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Temporal resolution and image quality are important factors to minimize planning target volume margin due to the respiratory motion. To achieve high temporal resolution and high signal-to-noise ratio, we developed a respiratory gated segment reconstruction algorithm and adapted it to Feldkamp-Davis-Kress algorithm (FDK) with a 256-detector row CT. The 256-detector row CT could scan approximately 100 mm in the cranio-caudal direction with 0.5 mm slice thickness in one rotation. Data acquisition for the RS-FDK relies on the assistance of the respiratory sensing system by a cine scan mode (table remains stationary). We evaluated RS-FDK in phantom study with the 256-detector row CT and compared it with full scan (FS-FDK) and HS-FDK results with regard to volume accuracy and image noise, and finally adapted the RS-FDK to an animal study. The RS-FDK gave a more accurate volume than the others and it had the same signal-to-noise ratio as the FS-FDK. In the animal study, the RS-FDK visualized the clearest edges of the liver and Pulmonary vessels of all the algorithms. In conclusion, the RS-FDK algorithm has a capability of high temporal resolution and high signal-to-noise ratio. Therefore it will be useful when combined with new radiotherapy techniques including image guided radiation therapy (IGRT) and 4D radiation therapy.
引用
收藏
页码:711 / 721
页数:11
相关论文
共 27 条
  • [1] Carol MP, 1995, 3-D RADIATION TREATMENT PLANNING AND CONFORMAL THERAPY, P435
  • [2] Development and performance evaluation of the first model of 4-D CT-scanner
    Endo, M
    Mori, S
    Tsunoo, T
    Kandatsu, S
    Tanada, S
    Aradate, H
    Saito, Y
    Miyazaki, H
    Satoh, K
    Matsusita, S
    Kusakabe, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1667 - 1671
  • [3] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [4] Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    Hanley, J
    Debois, MM
    Mah, D
    Mageras, GS
    Raben, A
    Rosenzweig, K
    Mychalczak, B
    Schwartz, LH
    Gloeggler, PJ
    Lutz, W
    Ling, CC
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 603 - 611
  • [5] Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
    Kanai, T
    Endo, M
    Minohara, S
    Miyahara, N
    Koyama-Ito, H
    Tomura, H
    Matsufuji, N
    Futami, Y
    Fukumura, A
    Hiraoka, T
    Furusawa, Y
    Ando, K
    Suzuki, M
    Soga, F
    Kawachi, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (01): : 201 - 210
  • [6] Motion adaptive x-ray therapy: a feasibility study
    Keall, PJ
    Kini, VR
    Vedam, SS
    Mohan, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) : 1 - 10
  • [7] Kini V. R., 2000, International Journal of Radiation Oncology Biology Physics, V48, P164, DOI 10.1016/S0360-3016(00)80122-4
  • [8] TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY
    MACKIE, TR
    HOLMES, T
    SWERDLOFF, S
    RECKWERDT, P
    DEASY, JO
    YANG, J
    PALIWAL, B
    KINSELLA, T
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1709 - 1719
  • [9] MAGERAS GS, 1999, PHYS MED, V15, P199
  • [10] Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer
    Mah, D
    Hanley, J
    Rosenzweig, KE
    Yorke, E
    Braban, L
    Ling, CC
    Leibel, SA
    Mageras, G