Development of a large-area monolithic 4 x 4 MPPC array for a future PET scanner employing pixelized Ce:LYSO and Pr:LuAG crystals

被引:32
作者
Kato, T. [1 ]
Kataoka, J. [1 ]
Nakamori, T. [1 ]
Miura, T. [1 ]
Matsuda, H. [1 ]
Sato, K. [2 ]
Ishikawa, Y. [2 ]
Yamamura, K. [2 ]
Kawabata, N. [2 ]
Ikeda, H. [3 ]
Sato, G. [3 ]
Kamada, K. [4 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, Tokyo, Japan
[2] Hamamatsu Photon KK, Div Solid State, Shizuoka, Japan
[3] ISAS JAXA, Chuo Ku, Sagamihara, Kanagawa, Japan
[4] Furukawa Co Ltd, Mat Res Lab, Tsukuba, Ibaraki 3050856, Japan
关键词
Multi-Pixel Photon Counter; Gamma-rays; Positron emission tomography; PHOTON COUNTERS; APD;
D O I
10.1016/j.nima.2011.02.049
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a new type of large-area monolithic Multi-Pixel Photon Counter (MPPC) array consisting of a 4 x 4 matrix of 3 x 3 mm(2) pixels. Each pixel comprises 3600 Geiger mode avalanche photodiodes (APDs) that achieve an average gain of 9.68 x 10(5) at 71.9 V at 0 degrees C with variations of only +/- 7.2% over 4 x 4 pixels. Excellent uniformity was also obtained for photon detection efficiencies (PDE) of +/- 6.4%, whilst dark count rates at the single photoelectron (1 p.e.) level amounted to similar or equal to 2 Mcps/pixel, measured at 0 degrees C. As the first step toward using the device in scintillation photon detectors, we fabricated a prototype gamma-ray camera consisting of an MPPC array optically coupled with a scintillator matrix, namely a 4 x 4 array of 3 x 3 x 10 mm(3) crystals. Specifically, we tested the performance with Ce-doped (Lu, Y)(2)(SiO4)O (Ce:LYSO), Pr-doped Lu3Al5O12 (Pr:LuAG) and "surface coated" Pr:LuAG (Pr:LuAG (WES)) matrices whereby the emission peak of Pr:LuAG was shifted from 310 to 420 nm via a wavelength shifter (WLS). Average energy resolutions of 13.83%, 14.70% and 13.96% (FWHM) were obtained for 662 keV gamma-rays, as measured at 0 degrees C with Ce:LYSO, Pr:LuAG and Pr:LuAG (WLS) scintillator matrices, respectively. We confirmed that the effective PDE for Pr:LuAG (WLS) had improved by more than 30% compared to original, non-coated Pr:LuAG matrix. These results suggest that a large-area monolithic MPPC array developed here could be promising for future medical imaging, particularly in positron emission tomography (PET). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 20 条
[11]   Preliminary results on the role of PET/CT in initial staging, restaging, and management of lung cancer [J].
Malamitsi, J. ;
Valotassiou, B. ;
Iliadis, K. ;
Kosmidis, P. ;
Laspas, F. ;
Vasilaki, M. ;
Pipini, E. ;
Petounis, A. ;
Gogou, L. ;
Pagou, M. ;
Dalianis, K. ;
Efthimiadou, R. ;
Andreou, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02) :319-322
[12]   Trends in PET imaging [J].
Moses, WW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) :209-214
[13]   Multi Pixel Photon Counters (MPPC) as an Alternative to APD in PET Applications [J].
Nassalski, A. ;
Moszynski, M. ;
Syntfeld-Kazuch, A. ;
Szczesniak, T. ;
Swiderski, L. ;
Wolski, D. ;
Batsch, T. ;
Baszak, J. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) :1008-1014
[14]   Proof-of-principle study of a small animal PET/field-cycled MRI combined system using conventional PMT technology [J].
Peng, Hao ;
Handler, William B. ;
Scholl, Timothy J. ;
Simpson, P. J. ;
Chronik, Blaine A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 612 (02) :412-420
[15]   Initial tests of a prototype MRI-compatible PET imager [J].
Raylman, Raymond R. ;
Majewski, Stan ;
Lemieux, Susan ;
Velan, S. Sendhil ;
Kross, Brain ;
Popov, Vladimir ;
Smith, Mark F. ;
Weisenberger, Andrew G. ;
Wojcik, Randy .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02) :306-309
[16]  
SZAWLOWSKI M, 2007, IEEE T NUCL SCI NM, V1, P4591
[17]   Preliminary studies of a simultaneous PET/MRI scanner based on the RatCAP small animal tomograph [J].
Woody, C. ;
Schlyer, D. ;
Vaska, P. ;
Tomasi, D. ;
Solis-Najera, S. ;
Rooney, W. ;
Pratte, J. -F. ;
Junnarkar, S. ;
Stoll, S. ;
Master, Z. ;
Purschke, M. ;
Park, S. -J ;
Southekal, S. ;
Kriplani, A. ;
Krishnamoorthy, S. ;
Maramraju, S. ;
O'Connor, P. ;
Radeka, V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :102-105
[18]   Development of multi-pixel photon counter (MPPC) [J].
Yamamoto, K. ;
Yamamura, K. ;
Sato, K. ;
Kamakura, S. ;
Ota, T. ;
Suzuki, H. ;
Ohsuka, S. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :1511-+
[19]   Development of Multi-Pixel Photon Counter (MPPC) [J].
Yamamoto, K. ;
Yamamura, K. ;
Sato, K. ;
Ota, T. ;
Suzuki, H. ;
Ohsuka, S. .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :1094-1097
[20]  
YOSHINO M, NUCL INST A IN PRESS