X-ray fluorescence elemental mapping and microscopy to follow hepatic disposition of a Gd-based magnetic resonance imaging contrast agent

被引:13
作者
Delfino, Riccarda [2 ]
Altissimo, Matteo [9 ,10 ]
Menk, Ralf Hendrik [4 ]
Alberti, Roberto [5 ,7 ]
Klatka, Tomasz [5 ,7 ]
Frizzi, Tommaso [5 ,7 ,8 ]
Longoni, Antonio [5 ,7 ]
Salome, Murielle [3 ,5 ]
Tromba, Giuliana [4 ]
Arfelli, Fulvia [3 ,5 ]
Clai, Milan [6 ]
Vaccari, Lisa [4 ]
Lorusso, Vito
Tiribelli, Claudio
Pascolo, Lorella [1 ,4 ]
机构
[1] IRCCS Burlo Garofolo, Inst Maternal & Child Hlth, I-34137 Trieste, Italy
[2] Univ Trieste, Dept Pharmaceut Sci, I-34127 Trieste, Italy
[3] Univ Trieste, Dept Phys, I-34127 Trieste, Italy
[4] Synchrotron Trieste SCpA, Trieste, Italy
[5] Ist Nazl Fis Nucl, Milan, Italy
[6] Univ Hosp Trieste, Trieste, Italy
[7] Politecn Milan, Dept Elect & Informat, Milan, Italy
[8] XGLab Srl, Milan, Italy
[9] CSIRO Mat Sci & Engn, Melbourne, Vic, Australia
[10] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
chemical imaging; liver; magnetic resonance imaging contrast agents; X-ray fluorescence; MONOLITHIC ARRAY; IN-VITRO; LIVER; GADOLINIUM; EXPRESSION; TRANSPORT; MICROPROBE; SPECIATION; B22956/1; CELLS;
D O I
10.1111/j.1440-1681.2011.05618.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
1. Spatially resolved X-ray fluorescence (XRF) spectroscopy with synchrotron radiation is a technique that allows imaging and quantification of chemical elements in biological specimens with high sensitivity. In the present study, we applied XRF techniques at a macro and micro level to carry out drug distribution studies on ex vivo models to confirm the hepatobiliary disposition of the Gd-based magnetic resonance imaging contrast agent B22956/1.
引用
收藏
页码:834 / 845
页数:12
相关论文
共 38 条
[1]   USB 2.0 data acquisition system for high-speed X-ray elemental mapping [J].
Alberti, R. ;
Guazzoni, C. ;
Klatka, T. .
JOURNAL OF INSTRUMENTATION, 2008, 3
[2]   Elemental mapping by means of an ultra-fast XRF spectrometer based on a novel high-performance monolithic array of Silicon Drift Detectors [J].
Alberti, R. ;
Florini, C. ;
Guazzoni, C. ;
Klatka, T. ;
Longoni, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :1004-1007
[3]   Performance evaluation of an advanced XRF elemental mapping system featuring a novel ring-shaped monolithic array of silicon drift detectors [J].
Alberti, R. ;
Buzzetti, S. ;
Fiorini, C. ;
Guazzoni, C. ;
Klatka, T. ;
Lechner, P. ;
Longoni, A. ;
Strueder, L. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) :751-757
[4]  
Alberti R, 2006, IEEE NUCL SCI CONF R, P1528
[5]   Coordinated expression of multidrug resistance-associated proteins (Mrps) in mouse liver during toxicant-induced injury [J].
Aleksunes, LM ;
Scheffer, GL ;
Jakowski, AB ;
Pruimboom-Brees, IM ;
Manautou, JE .
TOXICOLOGICAL SCIENCES, 2006, 89 (02) :370-379
[6]   Tracing exogenous Gd and its effects in single Chang cells [J].
Altissimo, Matteo ;
Pascolo, Lorella ;
Delfino, Riccarda ;
Salome, Murielle ;
Lorusso, Vito .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) :348-352
[7]   Conjugates of gadolinium complexes to bile acids as hepatocyte-directed contrast agents for magnetic resonance Imaging [J].
Anelli, PL ;
Lattuada, L ;
Lorusso, V ;
Lux, G ;
Morisetti, A ;
Morosini, P ;
Serleti, M ;
Uggeri, F .
JOURNAL OF MEDICINAL CHEMISTRY, 2004, 47 (14) :3629-3641
[8]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[9]  
BOWLER JM, 1995, J MEMBRANE BIOL, V145, P175
[10]   Preclinical profile and clinical potential of gadocoletic acid trisodium salt (B22956/1), a new intravascular contrast medium for MRI [J].
Cavagna, FM ;
Lorusso, V ;
Anelli, PL ;
Maggioni, F ;
de Haën, C .
ACADEMIC RADIOLOGY, 2002, 9 :S491-S494