Double skin facade assessment by fuzzy AHP and comparison with AHP

被引:15
作者
Bostancioglu, Esra [1 ]
机构
[1] Istanbul Kultur Univ, Dept Architecture, Istanbul, Turkey
关键词
Double-skin facade (DSF); fuzzy Analytic hierarchy process (FAHP); multi-storey DSF; corridor DSF; shaft-box DSF; box window DSF; LIFE-CYCLE ASSESSMENT; AIR-FLOW; BUILDINGS; ENERGY; SIMULATION; PERSPECTIVES; PERFORMANCE; CONVECTION; SELECTION; SYSTEM;
D O I
10.1080/17452007.2020.1735292
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A double-skin facade (DSF) has been widely used in recent years for its thermal and aesthetic properties. DSFs can also control wind pressure, manage natural ventilation and provide noise insulation. This study aims at providing an assessment of DSF to building designers and builders with their selection of facade systems. The decisions taken on the selection of facade systems are complicated ones based on multiple criteria. A decision must be taken only after many criteria are evaluated. While certain criteria such as heat insulation, noise insulation, and cost can be easily quantified, it is difficult to measure subjective criteria such as aesthetics. Therefore, the study aims at reflecting the experience of professionals who have applied such facade systems, to be able to evaluate all assessment criteria and facade systems. Architects or engineers working in the construction sector assessed criteria and DSF alternatives by replying to a questionnaire. Fuzzy set theory aids in measuring the ambiguity of concepts that are associated with human being's subjective judgment. Fuzzy Analytic Hierarchy Process (FAHP) has been applied to many assessment problems. It is used for the assessment of DSF in this study. AHP was used for the assessment of DSF in our previous study. The results of our previous study are also compared with the results of this study and findings are presented.
引用
收藏
页码:110 / 130
页数:21
相关论文
共 70 条
[1]  
Ahmed Mostafa M. S., 2016, Journal of Clean Energy Technologies, V4, P84, DOI 10.7763/JOCET.2016.V4.258
[2]   Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade [J].
Andelkovic, Aleksandar S. ;
Gvozdenac-Urosevic, Branka ;
Kljajic, Miroslav ;
Ignjatovic, Marko G. .
ENERGY AND BUILDINGS, 2015, 86 :766-781
[3]  
ANDRESEN I, 2002, STF22A01016 SINTEF
[4]  
[Anonymous], 2008, THESIS
[5]  
[Anonymous], 1997, International Journal of Project Management, DOI DOI 10.1016/S0263-7863(96)00076-2
[6]   Evaluation of firms applying to Malcolm Baldrige National Quality Award: a modified fuzzy AHP method [J].
Aydin, Serhat ;
Kahraman, Cengiz .
COMPLEX & INTELLIGENT SYSTEMS, 2019, 5 (01) :53-63
[7]   Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin facade in Mediterranean climates [J].
Ballestini, G ;
De Carli, M ;
Masiero, N ;
Tombola, G .
BUILDING AND ENVIRONMENT, 2005, 40 (07) :983-995
[8]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[9]   Applying analytic hierarchy process to the evaluation of double skin facades [J].
Bostancioglu, Esra ;
Onder, N. Pinar .
ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2019, 15 (01) :66-82
[10]   FUZZY HIERARCHICAL ANALYSIS [J].
BUCKLEY, JJ .
FUZZY SETS AND SYSTEMS, 1985, 17 (03) :233-247