Signal correction using molecular species to improve biodiesel analysis by microwave-induced plasma optical emission spectrometry

被引:25
作者
Lowery, Kenneth L. [1 ]
McSweeney, Tina [2 ]
Adhikari, Shiba P. [1 ]
Lachgar, Abdessadek [1 ]
Donati, George L. [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Salem Hall Box 7486, Winston Salem, NC 27109 USA
[2] Agilent Technol, 2500 Regency Pkwy, Cary, NC 27518 USA
关键词
Biodiesel analysis; N-2(+); OH radical; N-2; plasma; Signal correction; Calibration; METALS;
D O I
10.1016/j.microc.2016.06.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave-induced plasma optical emission spectrometry (MIP OES) and a simple dilute-and-shoot sample preparation procedure with 1-propanol are used to determine Ca, K, Mg and Na in biodiesel fuel. MIP naturally occurring molecular species are used to probe plasma condition variations during sample introduction, and then correct analytical signals to improve accuracies. The electronic transitions for N-2(+)(0-0, B-2 Sigma(+)(u) -> X-2 Sigma(+)(g)) and OH (0-0, A(2)Sigma(+) -> X-2 pi(i)) are used as molecular probes. A biodiesel standard reference sample is analyzed and the results for the molecular probe signal correction method are compared with values obtained with a traditional external standard calibration (EC). Improved accuracies were observed for Ca using the N-2(+) probe, and for K, Mg and Na using OH. Recoveries were in the 82-104% range for all analytes (60-130% for EC). The limits of detection (LODs) for Ca, K, Mg and Na are 70, 7, 9 and 8 mu g/L, respectively (2 mg/kg for Ca, and 0.2 mg/kg for all the other analytes). The method was applied to three biodiesel fuel samples and the concentrations ranges for Ca, K and Na were 9.0-16.0,10.6-142.1, and 7.8-52.7 mg/kg, respectively. Magnesium values were lower than the LOD in all cases. Analytical signal correction using plasma naturally occurring molecular species has the potential to significantly improve accuracy and sample throughput. It allows for effective determinations without the need for time-consuming calibration methods such as standard additions. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 62
页数:5
相关论文
共 27 条
  • [1] A simple dilute-and-shoot procedure for Si determination in diesel and biodiesel by microwave-induced plasma optical emission spectrometry
    Amais, Renata S.
    Donati, George L.
    Schiavo, Daniela
    Nobrega, Joaquim A.
    [J]. MICROCHEMICAL JOURNAL, 2013, 106 : 318 - 322
  • [2] Determination of Ca, Mg, and Zn in biodiesel microemulsions by FAAS using discrete nebulization
    Amais, Renata S.
    Garcia, Edivaldo E.
    Monteiro, Marcos R.
    Nobrega, Joaquim A.
    [J]. FUEL, 2012, 93 (01) : 167 - 171
  • [3] Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry
    Avila Orozco, Francisco D.
    Kovachev, Nikolay
    Aguirre Pastor, Miguel Angel
    Domini, Claudia E.
    Fernandez Band, Beatriz S.
    Canals Hernandez, Antonio
    [J]. ANALYTICA CHIMICA ACTA, 2014, 827 : 15 - 21
  • [4] Barros S., 2015, BR15006 GAIN
  • [5] Determination of trace elements in biodiesel and vegetable oil by inductively coupled plasma optical emission spectrometry following alcohol dilution
    Chaves, Eduardo S.
    de Loos-Vollebregt, Margaretha T. C.
    Curtius, Adilson J.
    Vanhaecke, Frank
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (9-10) : 733 - 739
  • [6] Biodiesel production in Brazil: Current scenario and perspectives
    Cremonez, Paulo Andre
    Feroldi, Michael
    Nadaleti, Willian Cezar
    de Rossi, Eduardo
    Feiden, Armin
    de Camargo, Mariele Pasuch
    Cremonez, Filipe Eliazar
    Klajn, Felipe Fernandes
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 42 : 415 - 428
  • [7] ICPOES simultaneous determination of Ca, Cu, Fe, Mg, Mn, Na, and P in biodiesel by axial and radial Inductively Coupled Plasma-Optical Emission Spectrometry
    de Souza, Roseli Martins
    Leocadio, Luiz Gustavo
    da Silveira, Carmem Lucia P.
    [J]. ANALYTICAL LETTERS, 2008, 41 (09) : 1615 - 1622
  • [8] Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers
    Dennaud, J
    Howes, A
    Poussel, E
    Mermet, JM
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (01) : 101 - 112
  • [9] Determination of Cr, Ni, Pb and V in gasoline and ethanol fuel by microwave plasma optical emission spectrometry
    Donati, George L.
    Amais, Renata S.
    Schiavo, Daniela
    Nobrega, Joaquim A.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (05) : 755 - 759
  • [10] European Committee for Standardization, 2008, 14214 EN