An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin
被引:22
|
作者:
Noureen, Beenish
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Noureen, Beenish
[1
]
Ullah, Najeeb
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Dept Biochem & Mol Biol, Xian 710061, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Ullah, Najeeb
[2
]
Tian, Yulan
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Tian, Yulan
[1
]
Du, Liping
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Zhejiang Univ, Dept Biomed Engn, Biosensor Natl Special Lab, Key Lab Biomed Engn,Minist Educ, Hangzhou 310027, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Du, Liping
[1
,3
]
Chen, Wei
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Chen, Wei
[1
]
Wu, Chunsheng
论文数: 0引用数: 0
h-index: 0
机构:
Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Wu, Chunsheng
[1
]
Wang, Ping
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Dept Biomed Engn, Biosensor Natl Special Lab, Key Lab Biomed Engn,Minist Educ, Hangzhou 310027, Peoples R ChinaXi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
Wang, Ping
[3
]
机构:
[1] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Inst Med Engn,Dept Biophys, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Hlth Sci Ctr, Sch Basic Med Sci, Dept Biochem & Mol Biol, Xian 710061, Shaanxi, Peoples R China
[3] Zhejiang Univ, Dept Biomed Engn, Biosensor Natl Special Lab, Key Lab Biomed Engn,Minist Educ, Hangzhou 310027, Peoples R China
Saxitoxin (STX), is one of the most dangerous and widespread paralytic shellfish toxins, causing a severe threat to the ecosystem and human health. So, it is important and highly essential to develop novel techniques for STX detection in a convenient, desirable, and low-cost manner. Herein, this study developed an electrolyte-insulator semiconductor (EIS) sensor covered with a layer-by-layer prepared, positively-charged weak polyelectrolyte layer of poly (allylamine hydrochloride) (PAH) for the label-free detection of STX. The specific aptamer (Apt) sensitive to STX was electrostatically adsorbed onto the PAH layer. This leads to a preferentially flat orientation of the Apt within the Debye length, thus yielding a reduced charge-screening influence and a higher sensor signal. Each step of sensor surface modification, i.e. PAH adsorption, immobilization of Apt, and attachment of STX, was monitored by capacitance-voltage (C-V) and constant-capacitance (ConCap) measurements. Furthermore, atomic force microscopy (AFM) was employed to characterize the surface morphology and roughness of the PAH layer. Fluorescence microscopy was used to confirm the effective immobilization of Apt onto the PAHmodified EIS sensor. The results showed that the detection range of this aptasensor for STX detection was 0.5-100 nM and the detection limit was as low as 0.05 nM. Furthermore, this aptasensor showed good selectivity and 9 days' stability. The mussel tissue extraction test suggested that this aptasensor can be used to detect STX in real samples. This aptasensor provides a convenient approach for moderate, rapid, and label-free detection of marine biological toxins.